User Verification Leveraging Gait Recognition for Smartphone Enabled Mobile Healthcare Systems
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The rapid deployment of sensing technology in smartphones and the explosion of their usage in people's daily lives provide users with the ability to collectively sense the world. This leads to a growing trend of mobile healthcare systems utilizing sensing data collected from smartphones with/without additional external sensors to analyze and understand people's physical and mental states. However, such healthcare systems are vulnerable to user spoofing, in which an adversary distributes his registered device to other users such that data collected from these users can be claimed as his own to obtain more healthcare benefits and undermine the successful operation of mobile healthcare systems. Existing mitigation approaches either only rely on a secret PIN number (which can not deal with colluded attacks) or require an explicit user action for verification. In this paper, we propose a user verification system leveraging unique gait patterns derived from acceleration readings to detect possible user spoofing in mobile healthcare systems. Our framework exploits the readily available accelerometers embedded within smartphones for user verification. Specifically, our user spoofing mitigation framework (which consists of three components, namely Step Cycle Identification, Step Cycle Interpolation, and Similarity Comparison) is used to extract gait patterns from run-time accelerometer measurements to perform robust user verification under various walking speeds. We show that our framework can be implemented in two ways: user-centric and server-centric, and it is robust to not only random but also mimic attacks. Our extensive experiments using over 3,000 smartphone-based traces with mobile phones placed on different body positions confirm the effectiveness of the proposed framework with users walking at various speeds. This strongly indicates the feasibility of using smartphone based low grade accelerometer to conduct gait recognition and facilitate effective user verification without active user cooperation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Activity recognition has been used in a number of situations [23]–[25], like individual authentication [26]–[28], medical examination [29], [30], elderly person wellness monitoring, development of wearable and smartphone based tracking systems, and impersonation attack protection [56].”
From Deep CNN-LSTM With Self-Attention Model for Human Activity Recognition Using Wearable Sensor (2022) · cites this paper as [29]
Citations
Cites
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Casella, G., & Berger, R. (2024) · Chapman & Hall/CRC eBooks · doi:10.1201/9781003456285 · Cited by 5,711
Buckingham, R. A. (1966) · Cited by 2,899
Individual recognition using gait energy image
Han, J., & Bhanu, B. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.38 · Cited by 1,847
Vaughan, C. L., Davis, B. L., & O’Connor, J. (1992) · Medical Entomology and Zoology · Cited by 798
A survey for assessing physical activity among older adults
DIPIETRO, L., CASPERSEN, C. J., OSTFELD, A. M., & NADEL, E. R. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199305000-00016 · Cited by 708
Oresko, J. J., Jin, Z., Cheng, J., Huang, S., Sun, Y., Duschl, H., & Cheng, A. C. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2047865 · Cited by 446
Identifying Users of Portable Devices from Gait Pattern with Accelerometers
Mantyjarvi, J., Lindholm, M., Vildjiounaite, E., Makela, S., & Ailisto, H. (2006) · Proceedings. (ICASSP '05). IEEE International Conference on Acoustics, Speech, and Signal Processing, 2005. · doi:10.1109/icassp.2005.1415569 · Cited by 408
Angus, J. E. (1991) · Technometrics · doi:10.1080/00401706.1991.10484898 · Cited by 405
Improved gait recognition by gait dynamics normalization
Liu, Z., & Sarkar, S. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.122 · Cited by 335
Cited by
Enabling Technologies for the Internet of Health Things
Rodrigues, J. J. P. C., De Rezende Segundo, D. B., Junqueira, H. A., Sabino, M. H., Prince, R. M., Al-Muhtadi, J., & De Albuquerque, V. H. C. (2018) · IEEE Access · doi:10.1109/access.2017.2789329 · Cited by 413
“[48] also proposed a user verification system leveraging unique gait patterns derived from acceleration readings (embedded within smartphones) to detect possible user spoofing in m-healthcare systems.”
BackgroundInertial Sensor-Based Gait Recognition: A Review
Sprager, S., & Juric, M. (2015) · Sensors · doi:10.3390/s150922089 · Cited by 347
“Existing cycle-based gait recognition approaches rely on gait detection methods that leverage local extrema analysis in a most common way [23,24,31,32,49,60–67], as well as zero-crossing detection [25,40,41,58,68], salience vector detection [69,70], phase analysis [28,42], detection of dynamic variations [71] and corr…”
BackgroundMethodInfluentialDeep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2020) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2020.2985628 · Cited by 305
“g, person authentication [23], [24], [63], medical analysis [64]–[66], and impersonation-attack defense [67].”
BackgroundDeep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2018) · arXiv · doi:10.48550/arxiv.1811.00338 · Cited by 305
Deep CNN-LSTM With Self-Attention Model for Human Activity Recognition Using Wearable Sensor
Khatun, M. A., Yousuf, M. A., Ahmed, S., Uddin, M. Z., Alyami, S. A., Al-Ashhab, S., Akhdar, H. F., Khan, A., Azad, A., & Moni, M. A. (2022) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2022.3177710 · Cited by 288
“RELATED WORK Activity recognition has been used in a number of situations [23]–[25], like individual authentication [26]–[28], medical examination [29], [30], elderly person wellness”
Metadata
- Authors
- Ren, Y., Chen, Y., Chuah, M. C., & Yang, J.
- Affiliations
- Stevens Institute of Technology (US)
- Lehigh University (US)
- Florida State University (US)
- Venue
- IEEE Transactions on Mobile Computing
- Published
- 2015-09-01
- Volume
- 14
- Issue
- 9
- Pages
- 1961-1974
- ISSN
- 1536-1233 (ISSN-L)
- OpenAlex
- W2066236160
- Cited by
- 123
- References
- 34
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 12 · 2023: 13 · 2022: 20 · 2021: 11 · 2020: 15 · 2019: 9 · 2018: 11 · 2017: 13 · 2016: 8 · 2015: 1
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Mobile Computing (publishedVersion)
- Funders
- National Science Foundation (CNS1016303, CNS1217387, CCF1018270, CNS1016296, CNS1217379, CNS1409767)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Computer Science › Information Systems › User Authentication and Security Systems
- Physical Sciences › Computer Science › Computer Networks and Communications › Advanced Authentication Protocols Security
- Keywords
- user verification, gait recognition, smartphone accelerometer, mobile health, wearable sensing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.