Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

User Verification Leveraging Gait Recognition for Smartphone Enabled Mobile Healthcare Systems

Ren, Yanzhi, Chen, Yingying, Chuah, Mooi Choo, Yang, Jie · 2015 · IEEE Transactions on Mobile Computing

Abstract

The rapid deployment of sensing technology in smartphones and the explosion of their usage in people's daily lives provide users with the ability to collectively sense the world. This leads to a growing trend of mobile healthcare systems utilizing sensing data collected from smartphones with/without additional external sensors to analyze and understand people's physical and mental states. However, such healthcare systems are vulnerable to user spoofing, in which an adversary distributes his registered device to other users such that data collected from these users can be claimed as his own to obtain more healthcare benefits and undermine the successful operation of mobile healthcare systems. Existing mitigation approaches either only rely on a secret PIN number (which can not deal with colluded attacks) or require an explicit user action for verification. In this paper, we propose a user verification system leveraging unique gait patterns derived from acceleration readings to detect possible user spoofing in mobile healthcare systems. Our framework exploits the readily available accelerometers embedded within smartphones for user verification. Specifically, our user spoofing mitigation framework (which consists of three components, namely Step Cycle Identification, Step Cycle Interpolation, and Similarity Comparison) is used to extract gait patterns from run-time accelerometer measurements to perform robust user verification under various walking speeds. We show that our framework can be implemented in two ways: user-centric and server-centric, and it is robust to not only random but also mimic attacks. Our extensive experiments using over 3,000 smartphone-based traces with mobile phones placed on different body positions confirm the effectiveness of the proposed framework with users walking at various speeds. This strongly indicates the feasibility of using smartphone based low grade accelerometer to conduct gait recognition and facilitate effective user verification without active user cooperation.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmc.2014.2365185

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Cited by

Metadata

Authors
Ren, Y., Chen, Y., Chuah, M. C., & Yang, J.
Affiliations
  • Stevens Institute of Technology (US)
  • Lehigh University (US)
  • Florida State University (US)
Venue
IEEE Transactions on Mobile Computing
Published
2015-09-01
Volume
14
Issue
9
Pages
1961-1974
ISSN
1536-1233 (ISSN-L)
OpenAlex
W2066236160
Cited by
123
References
34
Citations by year
2026: 4 · 2025: 6 · 2024: 12 · 2023: 13 · 2022: 20 · 2021: 11 · 2020: 15 · 2019: 9 · 2018: 11 · 2017: 13 · 2016: 8 · 2015: 1
FWCI
3.81
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Mobile Computing (publishedVersion)
Funders
National Science Foundation (CNS1016303, CNS1217387, CCF1018270, CNS1016296, CNS1217379, CNS1409767)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
  • Physical Sciences › Computer Science › Information Systems › User Authentication and Security Systems
  • Physical Sciences › Computer Science › Computer Networks and Communications › Advanced Authentication Protocols Security
Keywords
user verification, gait recognition, smartphone accelerometer, mobile health, wearable sensing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.