The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A new type of fish-like underwater microrobot
Abstract
This paper presents a new prototype model of an underwater fish-like microrobot utilizing ionic conducting polymer film (ICPF) actuator as the servo actuator to realize swimming motion with three degrees of freedom. A biomimetic fish-like microrobot using ICPF actuator as a propulsion tail fin and a buoyancy adjuster for the swimming structure in water or aqueous medium is developed. The overall size of the underwater prototype fish shaped microrobot is 45 mm in length, 10 mm in width, and 4 mm in thickness. It has two tails with a fin driven respectively, a body posture adjuster, and a buoyancy adjuster. The moving characteristic of the underwater microrobot is measured by changing the frequency of input voltage from 0.1-5 Hz in water and the amplitude of input voltage from 0.5-10 V. The experimental results indicate that changing the amplitude and frequency of input voltage can control the swimming speed of proposed underwater microrobot.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A polymer gel with electrically driven motility
Osada, Y., Okuzaki, H., & Hori, H. (1992) · Nature · doi:10.1038/355242a0 · Cited by 1,306
Bone, Q., & Moore, R. (1982) · Medical Entomology and Zoology · Cited by 541
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Lee, C., Kim, M., Kim, Y. J., Hong, N., Ryu, S., Kim, H. J., & Kim, S. (2017) · International Journal of Control, Automation and Systems · doi:10.1007/s12555-016-0462-3 · Cited by 616
MEMS-based micropumps in drug delivery and biomedical applications
Nisar, A., Afzulpurkar, N., Mahaisavariya, B., & Tuantranont, A. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.064 · Cited by 614
Mechanics and Control of Swimming: A Review
Colgate, J. E., & Lynch, K. M. (2004) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2004.833208 · Cited by 428
Recent advances in ionic polymer–metal composite actuators and their modeling and applications
Jo, C., Pugal, D., Oh, I.-K., Kim, K. J., & Asaka, K. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.04.003 · Cited by 406
Self-citation
Metadata
- Authors
- Guo, S., Fukuda, T., & Asaka, K.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2003-03
- Volume
- 8
- Issue
- 1
- Pages
- 136-141
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2108623852
- Cited by
- 384
- References
- 2
- FWCI
- 35.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new type of fish-like underwater microrobot. https://app.cochat.ai/papers/10.1109/tmech.2003.809134
- The paper
- Guo, S., Fukuda, T., & Asaka, K. (2003). A new type of fish-like underwater microrobot. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2003.809134
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.