The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A Supervised Feature-Projection-Based Real-Time EMG Pattern Recognition for Multifunction Myoelectric Hand Control
Abstract
Electromyographic (EMG) pattern recognition is essential for the control of a multifunction myoelectric hand. The main goal of this study was to develop an efficient feature- projection method for EMG pattern recognition. To this end, a linear supervised feature projection is proposed that utilizes a linear discriminant analysis (LDA). First, a wavelet packet transform (WPT) is performed to extract a feature vector from four-channel EMG signals. To dimensionally reduce and cluster the WPT features, an LDA, then, incorporates class information into the learning procedure, and identifies a linear matrix to maximize the class separability for the projected features. Finally, a multilayer perceptron classifies the LDA-reduced features into nine hand motions. To evaluate the performance of the LDA for WPT features, the LDA is compared with three other feature-projection methods. From a visualization and quantitative comparison, it is shown that the LDA produces a better performance for the class separability, plus the LDA-projected features improve the classification accuracy with a short processing time. A real-time pattern-recognition system is then implemented for a multifunction myoelectric hand. Experiments show that the proposed method achieves a 97.4% recognition accuracy, and all processes, including the generation of control commands for the myoelectric hand, are completed within 97 ms. Consequently, these results confirm that the proposed method is applicable to real-time EMG pattern recognition for multifunction myoelectric hand control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372
Kohonen, T. (1990) · Proceedings of the IEEE · doi:10.1109/5.58325 · Cited by 8,414
A Nonlinear Mapping for Data Structure Analysis
Sammon, J. W. (1969) · IEEE Transactions on Computers · doi:10.1109/t-c.1969.222678 · Cited by 3,380
Barker, L. (2002) · Technometrics · doi:10.1198/tech.2002.s659 · Cited by 2,477
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
DLR-Hand II: next generation of a dextrous robot hand
Butterfass, J., Grebenstein, M., Liu, H., & Hirzinger, G. (2002) · Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164) · doi:10.1109/robot.2001.932538 · Cited by 808
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Classification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
Cited by
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Guo, W., Zheng, P., Huang, X., Zhuo, H., Wu, Y., Yin, Z., Li, Z., & Wu, H. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b21836 · Cited by 125
Design, control, and sensory feedback of externally powered hand prostheses: a literature review
Cloutier, A., & Yang, J. (2013) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2013007887 · Cited by 36
Studies on biomedical signal processing: a review
Jalagam, M. K., & Mittal, V. K. (2024) · AIP Conference Proceedings · doi:10.1063/5.0159010 · Cited by 4
Metadata
- Authors
- Chu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2007-06
- Volume
- 12
- Issue
- 3
- Pages
- 282-290
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2122936696
- Cited by
- 299
- References
- 21
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Supervised Feature-Projection-Based Real-Time EMG Pattern Recognition for Multifunction Myoelectric Hand Control. https://app.cochat.ai/papers/10.1109/tmech.2007.897262
- The paper
- Chu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007). A Supervised Feature-Projection-Based Real-Time EMG Pattern Recognition for Multifunction Myoelectric Hand Control. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2007.897262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.