The DOI matches its Crossref record.
Fabrication and Application of Miniaturized Dielectric Elastomer Stack Actuators
Abstract
In dielectric elastomer stack actuators (DEAs), the driving voltage is reduced using thin dielectric layers. They are efficiently fabricated in an automated process. To produce thin dielectric films, uncured polydimethylsiloxane (PDMS) is spun to a thickness below 100 μm. After curing graphite, electrodes are sprayed on the PDMS surface and the next dielectric film can be applied on top. The main process steps are explained in detail. We show that the thickness variation within one layer is smaller than 4%. The electrodes are sprayed to have a sheet resistance of 10 kΩ/sq. The technology presented here is able to produce DEAs with layer thicknesses down to 5 μm. Hence, it is possible to design and fabricate actuators, which are driven only at 150 V. Arrays of small actuators with a resolution of 1 mm can be produced as well as single actuator elements with a diameter up to 40 mm. Finally, the potential of this technology is demonstrated by two examples varying highly in their application. The first application is a vibrotactile display. It generates a perceptive vibration of 125 Hz at a driving voltage of 600 V. The second application is a peristaltic pump with a maximum flow rate of 12 μL/min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multi-functional dielectric elastomer artificial muscles for soft and smart machines
Anderson, I. A., Gisby, T. A., McKay, T. G., O’Brien, B. M., & Calius, E. P. (2012) · Journal of Applied Physics · doi:10.1063/1.4740023 · Cited by 619
Flexible and stretchable electrodes for dielectric elastomer actuators
Rosset, S., & Shea, H. R. (2013) · Applied Physics A · doi:10.1007/s00339-012-7402-8 · Cited by 529
A survey on dielectric elastomer actuators for soft robots
Gu, G.-Y., Zhu, J., Zhu, L.-M., & Zhu, X. (2017) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/12/1/011003 · Cited by 483
Compact Dielectric Elastomer Linear Actuators
Zhao, H., Hussain, A. M., Duduta, M., Vogt, D. M., Wood, R. J., & Clarke, D. R. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201804328 · Cited by 274
Electroactive Polymers: Developments of and Perspectives for Dielectric Elastomers
Biggs, J., Danielmeier, K., Hitzbleck, J., Krause, J., Kridl, T., Nowak, S., Orselli, E., Quan, X., Schapeler, D., Sutherland, W., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201301918 · Cited by 264
Metadata
- Authors
- Lotz, P., Matysek, M., & Schlaak, H. F.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2011-02
- Volume
- 16
- Issue
- 1
- Pages
- 58-66
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2155401647
- Cited by
- 182
- References
- 0
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication and Application of Miniaturized Dielectric Elastomer Stack Actuators. https://app.cochat.ai/papers/10.1109/tmech.2010.2090164
- The paper
- Lotz, P., Matysek, M., & Schlaak, H. F. (2011). Fabrication and Application of Miniaturized Dielectric Elastomer Stack Actuators. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2010.2090164
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.