Fabrication and Application of Miniaturized Dielectric Elastomer Stack Actuators
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
In dielectric elastomer stack actuators (DEAs), the driving voltage is reduced using thin dielectric layers. They are efficiently fabricated in an automated process. To produce thin dielectric films, uncured polydimethylsiloxane (PDMS) is spun to a thickness below 100 μm. After curing graphite, electrodes are sprayed on the PDMS surface and the next dielectric film can be applied on top. The main process steps are explained in detail. We show that the thickness variation within one layer is smaller than 4%. The electrodes are sprayed to have a sheet resistance of 10 kΩ/sq. The technology presented here is able to produce DEAs with layer thicknesses down to 5 μm. Hence, it is possible to design and fabricate actuators, which are driven only at 150 V. Arrays of small actuators with a resolution of 1 mm can be produced as well as single actuator elements with a diameter up to 40 mm. Finally, the potential of this technology is demonstrated by two examples varying highly in their application. The first application is a vibrotactile display. It generates a perceptive vibration of 125 Hz at a driving voltage of 600 V. The second application is a peristaltic pump with a maximum flow rate of 12 μL/min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow of a Viscous Liquid on a Rotating Disk
Emslie, A. G., Bonner, F. T., & Peck, L. G. (1958) · Journal of Applied Physics · doi:10.1063/1.1723300 · Cited by 939 · cited 2×
“The derivation is shown in [17]; the result is as follows:”
BackgroundResultHigh-field deformation of elastomeric dielectrics for actuators
Pelrine, R., Kornbluh, R., Joseph, J., Heydt, R., Pei, Q., & Chiba, S. (2000) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(00)00128-4 · Cited by 696 · cited 1×
“The latter can be avoided by a physical vapor deposition process combined with a subsequent etching of the metallic film [21], [22].”
BackgroundDevelopment of Soft-Actuator-Based Wearable Tactile Display
Koo, I. M., Jung, K., Koo, J. C., Nam, J.-D., Lee, Y. K., & Choi, H. R. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.921561 · Cited by 277
Kornbluh, R. D., Pelrine, R., Pei, Q., Heydt, R., Stanford, S., Oh, S., & Eckerle, J. (2002) · SPIE Proceedings · doi:10.1117/12.475072 · Cited by 274 · cited 1×
“A rigid supporting structure ensures the actuator’s mechanical stiffness [1]–[5].”
BackgroundFault‐Tolerant Dielectric Elastomer Actuators using Single‐Walled Carbon Nanotube Electrodes
Yuan, W., Hu, L. B., Yu, Z. B., Lam, T., Biggs, J., Ha, S. M., Xi, D. J., Chen, B., Senesky, M. K., Grüner, G., et al. (2008) · Advanced Materials · doi:10.1002/adma.200701018 · Cited by 242 · cited 1×
“Graphite and carbon black have similar properties; nearly transparent electrodes have been shown by using carbon nanotubes [24].”
BackgroundOn the performance mechanisms of Dielectric Elastomer Actuators
Plante, J., & Dubowsky, S. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.01.017 · Cited by 175
Electrostrictive polymer artificial muscle actuators
Kornbluh, R. D., Pelrine, R. E., Eckerle, J. S., & Joseph, J. P. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1998.680638 · Cited by 149 · cited 1×
“In the active state, these actuators elongate along their axis [8]–[10].”
BackgroundBiomimetic Soft Actuator: Design, Modeling, Control, and Applications
Choi, H. R., Jung, K., Ryew, S. M., Nam, J., Jeon, J., Koo, J. C., & Tanie, K. (2005) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2005.856108 · Cited by 117
Dielectric elastomer actuators for tactile displays
Matysek, M., Lotz, P., Winterstein, T., & Schlaak, H. F. (2009) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2009.4810822 · Cited by 93 · cited 1×
“15 shows a vibrotactile user interface to display the actual operating state of a multimedia device [26], [27].”
BackgroundSelf-citationHydrostatically Coupled Dielectric Elastomer Actuators
Carpi, F., Frediani, G., & Rossi, D. D. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2021651 · Cited by 85 · cited 1×
“These bubble-like actuators have typical diameters of several millimeters [ 7 ].”
Background
Cited by
Multi-functional dielectric elastomer artificial muscles for soft and smart machines
Anderson, I. A., Gisby, T. A., McKay, T. G., O’Brien, B. M., & Calius, E. P. (2012) · Journal of Applied Physics · doi:10.1063/1.4740023 · Cited by 619
Flexible and stretchable electrodes for dielectric elastomer actuators
Rosset, S., & Shea, H. R. (2013) · Applied Physics A · doi:10.1007/s00339-012-7402-8 · Cited by 529
A survey on dielectric elastomer actuators for soft robots
Gu, G.-Y., Zhu, J., Zhu, L.-M., & Zhu, X. (2017) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/12/1/011003 · Cited by 483
Compact Dielectric Elastomer Linear Actuators
Zhao, H., Hussain, A. M., Duduta, M., Vogt, D. M., Wood, R. J., & Clarke, D. R. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201804328 · Cited by 274
Electroactive Polymers: Developments of and Perspectives for Dielectric Elastomers
Biggs, J., Danielmeier, K., Hitzbleck, J., Krause, J., Kridl, T., Nowak, S., Orselli, E., Quan, X., Schapeler, D., Sutherland, W., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201301918 · Cited by 264
Multilayer Dielectric Elastomers for Fast, Programmable Actuation without Prestretch
Duduta, M., Wood, R. J., & Clarke, D. R. (2016) · Advanced Materials · doi:10.1002/adma.201601842 · Cited by 256
Li, S., Bai, H., Shepherd, R. F., & Zhao, H. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201813402 · Cited by 209
Electroactive polymer (EAP) actuators—background review
Bar-Cohen, Y., & Anderson, I. A. (2019) · Mechanics of Soft Materials · doi:10.1007/s42558-019-0005-1 · Cited by 171
“include stack actuator fabrication from pre-existing commercially available dielectric membrane material [66], spin coating [64], and screen printing of the electrode [31].”
BackgroundVeale, A. J., & Xie, S. Q. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.01.010 · Cited by 160
Electro-Active Polymer Based Soft Tactile Interface for Wearable Devices
Mun, S., Yun, S., Nam, S., Park, S. K., Park, S., Park, B. J., Lim, J. M., & Kyung, K.-U. (2018) · IEEE Transactions on Haptics · doi:10.1109/toh.2018.2805901 · Cited by 141
“As a representative candidate for the tactile actuator, electro-active polymer (EAP) actuator, particularly dielectric elastomer (DE) actuators have been given much attention due to their electrically induced large area strain that can be dynamically controllable and reproducible [5], [6], [7], [8], [9], [10], [11], […”
BackgroundMethod
Metadata
- Authors
- Lotz, P., Matysek, M., & Schlaak, H. F.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2011-02
- Volume
- 16
- Issue
- 1
- Pages
- 58-66
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2155401647
- Cited by
- 182
- References
- 14
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.