CoChat

Electro-Active Polymer Based Soft Tactile Interface for Wearable Devices

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

This paper reports soft actuator based tactile stimulation interfaces applicable to wearable devices. The soft actuator is prepared by multi-layered accumulation of thin electro-active polymer (EAP) films. The multi-layered actuator is designed to produce electrically-induced convex protrusive deformation, which can be dynamically programmable for wide range of tactile stimuli. The maximum vertical protrusion is and the output force is up to 255 mN. The soft actuators are embedded into the fingertip part of a glove and front part of a forearm band, respectively. We have conducted two kinds of experiments with 15 subjects. Perceived magnitudes of actuator's protrusion and vibrotactile intensity were measured with frequency of 1 Hz and 191 Hz, respectively. Analysis of the user tests shows participants perceive variation of protrusion height at the finger pad and modulation of vibration intensity through the proposed soft actuator based tactile interface.

Overview

Integrity signals

Registry

Crossref · 10.1109/toh.2018.2805901

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Research works printed but not linked: 1

  1. 10.1109/tmech.2011.2107526 · DOI

Cited by

See all 144

Metadata

Authors
Mun, S., Yun, S., Nam, S., Park, S. K., Park, S., Park, B. J., Lim, J. M., & Kyung, K.-U.
Affiliations
  • Electronics and Telecommunications Research Institute (KR)
  • Max Planck Institute for Intelligent Systems (DE)
  • Korea Advanced Institute of Science and Technology (KR)
Venue
IEEE Transactions on Haptics
Published
2018-01-01
Volume
11
Issue
1
Pages
15-21
ISSN
  • 1939-1412 (ISSN-L)
  • 2329-4051
  • 2334-0134
OpenAlex
W2792399726
Cited by
141
References
19
Citations by year
2026: 14 · 2025: 16 · 2024: 16 · 2023: 22 · 2022: 16 · 2021: 32 · 2020: 14 · 2019: 11
FWCI
8.47
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Haptics (publishedVersion)
  • PubMed (publishedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion)
Funders
  • Pioneer Program of Korea National Research Foundation (2013M3C1A3059557)
  • Electronics and Telecommunications Research Institute (ETRI) (18ZS1300)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Dielectric materials and actuators
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
Keywords
electroactive polymers, soft actuators, tactile stimulation, wearable devices, haptic interface, vibrotactile feedback, protrusion height, vibration intensity, user perception
MeSH terms
Wearable Electronic Devices, Equipment Design, Fingers, Humans, Man-Machine Systems, Physical Stimulation, Polymers, Touch, User-Computer Interface, Vibration, Touch Perception, Feedback, Sensory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electro-Active Polymer Based Soft Tactile Interface for Wearable Devices. https://app.cochat.ai/papers/10.1109/toh.2018.2805901
The paper
Mun, S., Yun, S., Nam, S., Park, S. K., Park, S., Park, B. J., Lim, J. M., & Kyung, K.-U. (2018). Electro-Active Polymer Based Soft Tactile Interface for Wearable Devices. IEEE Transactions on Haptics. https://doi.org/10.1109/toh.2018.2805901

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.