The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
LIMPACT:A Hydraulically Powered Self-Aligning Upper Limb Exoskeleton
Open accessAbstract
The LIMPACT is an exoskeleton developed to be used in identifying the reflex properties of the arm in stroke survivors. Information on joint reflexes helps in designing optimal patient specific therapy programs. The LIMPACT is dynamically transparent by combining a lightweight skeleton with high power to weight ratio actuators. The LIMPACT is supported by a passive weight balancing mechanism to compensate for the weight of the exoskeleton and the human arm. Various self-aligning mechanisms allow the human joint axes to align with the axes of the exoskeleton which ensure safety and short don/doff times. The torque-controlled motors have a maximum torque bandwidth of 97 Hz which is required for fast torque perturbations and smooth zero impedance control. The LIMPACT's weight is reduced five times as gravitational forces are lowered using a model-based gravity compensation algorithm. The impedance controller ensures tracking of a cycloidal joint angle reference. A cycloid with an amplitude of 1.3 rd and a maximum velocity of 6.5 rd/s has a maximum tracking error of only 7%. The LIMPACT fulfills the requirements to be used in future diagnostics measurements for stroke patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 4×
“Electric motors are most often chosen [10], [11], [14], [15], [17]–[20], [22], [28], [29], [44].”
BackgroundInfluential
Cited by
A Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Upper-Limb Robotic Exoskeletons for Neurorehabilitation: A Review on Control Strategies
Proietti, T., Crocher, V., Roby-Brami, A., & Jarrasse, N. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2552201 · Cited by 388
Metadata
- Authors
- Otten, A., Voort, C., Stienen, A., Aarts, R., van Asseldonk, E., & van der Kooij, H.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2015-10
- Volume
- 20
- Issue
- 5
- Pages
- 2285-2298
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2067188191
- Cited by
- 160
- References
- 1
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: LIMPACT:A Hydraulically Powered Self-Aligning Upper Limb Exoskeleton. https://app.cochat.ai/papers/10.1109/tmech.2014.2375272
- The paper
- Otten, A., Voort, C., Stienen, A., Aarts, R., van Asseldonk, E., & van der Kooij, H. (2015). LIMPACT:A Hydraulically Powered Self-Aligning Upper Limb Exoskeleton. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2014.2375272
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.