The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
An Improved Algorithm for Reprojecting Rays through Pixel Images
Abstract
It is often desired to calculate line integrals through a field of reconstructed CT density pixels for the purpose of improving CT image quality. Two algorithms widely published and discussed in the past are known to either degrade spatial resolution or generate errors in the results due to the discontinuous "square pixel" modeling of the reconstructed image. An algorithm is described, based on linear interpolation between pixels, which provides superior accuracy without unnecessary loss of resolution. It was tested on simulated data for a head section and on a narrow Gaussian density distribution. The experimental results demonstrated improved performance. The method is expected to prove useful for many types of post-reconstruction processing, including beam hardening, missing data, and noise supression algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Joseph, P. M., & Spital, R. D. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197801000-00017 · Cited by 281
Self-citationComputerized Tomography: The New Medical X-Ray Technology
Shepp, L. A., & Kruskal, J. B. (1978) · The American Mathematical Monthly · doi:10.1080/00029890.1978.11994611 · Cited by 222
Huesman, R. H. (1977) · Physics in Medicine and Biology · doi:10.1088/0031-9155/22/3/012 · Cited by 140
The exponential edge-gradient effect in X-ray computed tomography
Joseph, P. M., & Spital, R. D. (1981) · Physics in Medicine and Biology · doi:10.1088/0031-9155/26/3/010 · Cited by 113
Self-citationPost-reconstruction method for beam hardening in computerised tomography
Nalcioglu, O., & Lou, R. (1979) · Physics in Medicine and Biology · doi:10.1088/0031-9155/24/2/009 · Cited by 102
Cited by
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
Distance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459
An iterative maximum-likelihood polychromatic algorithm for CT
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959297 · Cited by 430
Liu, Y., Ma, J., Fan, Y., & Liang, Z. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7923 · Cited by 335
Metadata
- Authors
- Joseph, P. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-11
- Volume
- 1
- Issue
- 3
- Pages
- 192-196
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2016309987
- Cited by
- 375
- References
- 7
- FWCI
- 0.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Improved Algorithm for Reprojecting Rays through Pixel Images. https://app.cochat.ai/papers/10.1109/tmi.1982.4307572
- The paper
- Joseph, P. M. (1982). An Improved Algorithm for Reprojecting Rays through Pixel Images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.1982.4307572
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.