The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
An Iterative Image Space Reconstruction Algorthm Suitable for Volume ECT
Abstract
The trend in the design of scanners for positron emission computed tomography has traditionally been to improve the transverse spatial resolution to several millimeters while maintaining relatively coarse axial resolution (1-2 cm). Several scanners are being built with fine sampling in the axial as well as transverse directions, leading to the possibility of the true volume imaging. The number of possible coincidence pairs in these scanners is quite large. The usual methods of image reconstruction cannot handle these data without making approximations. It is computationally most efficient to reduce the size of this large, sparsely populated array by back-projecting the coincidence data prior to reconstruction. While analytic reconstruction techniques exist for back-projected data, an iterative algorithm may be necessary for those cases where the point spread function is spatially variant. A modification of the maximum likelihood algorithm is proposed to reconstruct these back-projected data. The method, the iterative image space reconstruction algorithm (ISRA), is able to reconstruct data from a scanner with a spatially variant point spread function in less time than other proposed algorithms. Results are presented for single-slice data, simulated and actual, from the PENN-PET scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Cited by
Algorithms for Nonnegative Matrix Factorization with the β-Divergence
Févotte, C., & Idier, J. (2011) · Neural Computation · doi:10.1162/neco_a_00168 · Cited by 663
Dell'Acqua, F., Scifo, P., Rizzo, G., Catani, M., Simmons, A., Scotti, G., & Fazio, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.033 · Cited by 304
Silverman, B. W., Jones, M. C., Wilson, J. D., & Nychka, D. W. (1990) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1990.tb01788.x · Cited by 274
A scaled gradient projection method for constrained image deblurring
Bonettini, S., Zanella, R., & Zanni, L. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/1/015002 · Cited by 254
Metadata
- Authors
- Daube-Witherspoon, M. E., & Muehllehner, G.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1986-06
- Volume
- 5
- Issue
- 2
- Pages
- 61-66
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2041115669
- Cited by
- 237
- References
- 2
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Iterative Image Space Reconstruction Algorthm Suitable for Volume ECT. https://app.cochat.ai/papers/10.1109/tmi.1986.4307748
- The paper
- Daube-Witherspoon, M. E., & Muehllehner, G. (1986). An Iterative Image Space Reconstruction Algorthm Suitable for Volume ECT. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.1986.4307748
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.