CoChat

Optimal Control Solutions to the Magnetic Resonance Selective Excitation Problem

Conolly, Steven, Nishimura, Dwight, Macovski, Albert · 1986 · IEEE Transactions on Medical Imaging
Cited by 278

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Most magnetic resonance imaging sequences employ field gradients and amplitude modulated RF pulses to excite only those spins lying in a specific plane. The fidelity of the resulting magnetization distribution is crucial to overall image resolution. Conventional RF-pulse design techniques rely on the small tip-angle approximation to Bloch's equation, which is inadequate for the design of 90 degrees and 180 degrees pulses. This paper demonstrates the existence of a selective pulse, and provides a sound mathematical and computational basis for pulse design. It is shown that the pulses are optimal in the class of piecewise continuous functions of duration T. An optimal pulse is defined as the pulse on the interval that achieves a magnetization profile "closest" to the desired distribution. Optimal control theory provides the mathematical basis for the new pulse design technique. Computer simulations have verified the efficacy of the 90 degrees and the 180 degrees inversion and "pancake-flip" optimal pulses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.1986.4307754

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Conolly, S., Nishimura, D., & Macovski, A.
Venue
IEEE Transactions on Medical Imaging
Published
1986-06
Volume
5
Issue
2
Pages
106-115
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W1973010030
Cited by
278
References
10
FWCI
7.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.