Implementing and Accelerating the EM Algorithm for Positron Emission Tomography
Abstract
Since the publication of Shepp and Vadi's [ 14] maximum likelihood reconstruction algorithm for emission tomography (ET), many medical research centers engaged in ET have made an effort to change their reconstruction algorithms to this new approach. Some have succeeded, while others claim they could not adopt this new approach primarily because of limited computing power. In this paper, we discuss techniques for reducing the computational requirements of the reconstruction algorithm. Specifically, the paper discusses the data structures one might use and ways of taking advantage of the geometry of the physical system. The paper also treats some of the numerical aspects of the EM (expectation maximization) algorithm, and ways of speeding up the numerical algorithm using some of the traditional techniques of numerical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Self-citation
Cited by
Herman, G. T., & Meyer, L. B. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.241889 · Cited by 486
Metadata
- Authors
- Kaufman, L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1987-03
- Volume
- 6
- Issue
- 1
- Pages
- 37-51
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W1987649450
- Cited by
- 293
- References
- 2
- FWCI
- 9.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementing and Accelerating the EM Algorithm for Positron Emission Tomography. https://app.cochat.ai/papers/10.1109/tmi.1987.4307796
- The paper
- Kaufman, L. (1987). Implementing and Accelerating the EM Algorithm for Positron Emission Tomography. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.1987.4307796