The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Implementing and Accelerating the EM Algorithm for Positron Emission Tomography
Abstract
Since the publication of Shepp and Vadi's [ 14] maximum likelihood reconstruction algorithm for emission tomography (ET), many medical research centers engaged in ET have made an effort to change their reconstruction algorithms to this new approach. Some have succeeded, while others claim they could not adopt this new approach primarily because of limited computing power. In this paper, we discuss techniques for reducing the computational requirements of the reconstruction algorithm. Specifically, the paper discusses the data structures one might use and ways of taking advantage of the geometry of the physical system. The paper also treats some of the numerical aspects of the EM (expectation maximization) algorithm, and ways of speeding up the numerical algorithm using some of the traditional techniques of numerical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Practical methods of optimization
(1988) · Mathematics and Computers in Simulation · doi:10.1016/0378-4754(88)90129-2 · Cited by 5,818
Maximum likelihood estimation from incomplete data via the EM algorithm
Dempster, A. P. (1977) · Journal of the Royal Statistical Society Series A (Statistics in Society) · Cited by 4,543
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Levary, R. R. (1982) · European Journal of Operational Research · doi:10.1016/0377-2217(82)90093-5 · Cited by 4,158
Himmelblau, D. M. (1972) · Cited by 2,532
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Basic Linear Algebra Subprograms for Fortran Usage
Lawson, C. L., Hanson, R. J., Kincaid, D. R., & Krogh, F. T. (1979) · ACM Transactions on Mathematical Software · doi:10.1145/355841.355847 · Cited by 1,634
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Self-citationThe Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission Tomography
Snyder, D. L., & Miller, M. I. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4334521 · Cited by 278
Computerized Tomography: The New Medical X-Ray Technology
Shepp, L. A., & Kruskal, J. B. (1978) · The American Mathematical Monthly · doi:10.1080/00029890.1978.11994611 · Cited by 222
Ter-Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 172
Lewitt, R. M., & Muehllehner, G. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307734 · Cited by 155
Snyder, D. L., & Politte, D. G. (1983) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1983.4332660 · Cited by 139
Photon Time-of-Flight-Assisted Positron Emission Tomography
Ter-Pogossian, M. M., Mullani, N. A., Ficke, D. C., Markham, J., & Snyder, D. L. (1981) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198104000-00014 · Cited by 116
Numerical Methods for Unconstrained Optimization
Rothwell, A. (2017) · Solid mechanics and its applications · doi:10.1007/978-3-319-55197-5_4 · Cited by 102
Maximum Likelihood PET with Real Data
Shepp, L. A., Vardi, Y., Ra, J. B., Hilal, S. K., & Cho, Z. H. (1984) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1984.4333398 · Cited by 64
Cited by
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Green, P. J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52985 · Cited by 1,241
Space-alternating generalized expectation-maximization algorithm
Fessler, J. A., & Hero, A. O. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.324732 · Cited by 1,063
Joint estimation of object and aberrations by using phase diversity
Paxman, R. G., Schulz, T. J., & Fienup, J. R. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.001072 · Cited by 502
Herman, G. T., & Meyer, L. B. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.241889 · Cited by 486
Metadata
- Authors
- Kaufman, L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1987-03
- Volume
- 6
- Issue
- 1
- Pages
- 37-51
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W1987649450
- Cited by
- 293
- References
- 17
- FWCI
- 9.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.