Local frequency representations for robust multimodal image registration
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Automatic registration of multimodal images involves algorithmically estimating the coordinate transformation required to align the data sets. Most existing methods in the literature are unable to cope with registration of image pairs with large nonoverlapping field of view (FOV). We propose a robust algorithm, based on matching dominant local frequency image representations, which can cope with image pairs with large nonoverlapping FOV. The local frequency representation naturally allows for processing the data at different scales/resolutions, a very desirable property from a computational efficiency view point. Our algorithm involves minimizing-over all rigid/affine transformations--the integral of the squared error (ISE or L2 E) between a Gaussian model of the residual and its true density function. The residual here refers to the difference between the local frequency representations of the transformed (by an unknown transformation) source and target data. We present implementation results for image data sets, which are misaligned magnetic resonance (MR) brain scans obtained using different image acquisition protocols as well as misaligned MR-computed tomography scans. We experimently show that our L2E-based scheme yields better accuracy over the normalized mutual information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance of optical flow techniques
Barron, J. L., Fleet, D. J., & Beauchemin, S. S. (1994) · International Journal of Computer Vision · doi:10.1007/bf01420984 · Cited by 4,305
Multichannel texture analysis using localized spatial filters
Bovik, A. C., Clark, M., & Geisler, W. S. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.41384 · Cited by 1,382 · cited 1×
“The complex 3-D Gabor functions have the following general form (see [5], [11], and [16]):”
Background
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
“[118] proposed the application of Gabor wavelet transform and Gaussian model of registration residua.”
MethodDeformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“used local frequency representations to tackle rigid/affine multi-modal registration [324].”
BackgroundMethodRobust Point Set Registration Using Gaussian Mixture Models
Jian, B., & Vemuri, B. C. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.223 · Cited by 975
Self-citationDRAMMS: Deformable registration via attribute matching and mutual-saliency weighting
Ou, Y., Sotiras, A., Paragios, N., & Davatzikos, C. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.07.002 · Cited by 407
Ma, J., Qiu, W., Zhao, J., Ma, Y., Yuille, A. L., & Tu, Z. (2015) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2014.2388434 · Cited by 280
Metadata
- Authors
- Liu, J., Vemuri, B. C., & Marroquin, J. L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-05
- Volume
- 21
- Issue
- 5
- Pages
- 462-469
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2118102973
- Cited by
- 70
- References
- 2
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Local frequency representations for robust multimodal image registration. https://app.cochat.ai/papers/10.1109/tmi.2002.1009382
- The paper
- Liu, J., Vemuri, B. C., & Marroquin, J. L. (2002). Local frequency representations for robust multimodal image registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2002.1009382
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.