The DOI matches its Crossref record.
Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects
Abstract
Electrical impedance spectroscopy (EIS) is a potential, noninvasive technique to image women for breast cancer. Studies have shown characteristic frequency dispersions in the electrical conductivity and permittivity of malignant versus normal tissue. Using a multifrequency EIS system, we imaged the breasts of 26 women. All patients had mammograms ranked using the American College of Radiology (ACR) BIRADS system. Of the 51 individual breasts imaged, 38 were ACR 1 negative, six had ACR 4-5 suspicious lesions, and seven had ACR 2 benign findings such as fibroadenomas or calcifications. A radially translatable circular array of 16 Ag/AgCl electrodes was placed around the breast while the patient lay prone. We applied trigonometric voltage patterns at ten frequencies between 10 and 950 kHz. Anatomically coronal images were reconstructed from this data using nonlinear partial differential equation methods. Typically, ACR 1-rated breasts were interrogated in a single central plane whereas ACR 2-5-rated breasts were imaged in multiple planes covering the region of suspicion. In general, a characteristic homogeneous image emerged for mammographically normal cases while focal inhomogeneities were observed in images from women with malignancies. Using a specific visual criterion, EIS images identified 83% of the ACR 4-5 lesions while 67% were detected using a numerical criterion. Overall, multifrequency electrical impedance imaging appears promising for detecting breast malignancies, but improvements must be made before the method reaches its full potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrical impedance spectroscopy study of biological tissues
Dean, D. A., Ramanathan, T., Machado, D., & Sundararajan, R. (2008) · Journal of Electrostatics · doi:10.1016/j.elstat.2007.11.005 · Cited by 299
ANN vs. SVM: Which one performs better in classification of MCCs in mammogram imaging
Ren, J. (2012) · Knowledge-Based Systems · doi:10.1016/j.knosys.2011.07.016 · Cited by 260
Dysregulation of the epithelial barrier by environmental and other exogenous factors
Mitamura, Y., Ogulur, I., Pat, Y., Rinaldi, A. O., Ardicli, O., Cevhertas, L., Brüggen, M., Traidl‐Hoffmann, C., Akdis, M., & Akdis, C. A. (2021) · Contact Dermatitis · doi:10.1111/cod.13959 · Cited by 85
Metadata
- Authors
- Kerner, T. E., Paulsen, K. D., Hartov, A., Soho, S. K., & Poplack, S. P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-06
- Volume
- 21
- Issue
- 6
- Pages
- 638-645
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2169496192
- Cited by
- 177
- References
- 0
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects. https://app.cochat.ai/papers/10.1109/tmi.2002.800606
- The paper
- Kerner, T. E., Paulsen, K. D., Hartov, A., Soho, S. K., & Poplack, S. P. (2002). Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2002.800606
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.