The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
A unifying framework for partial volume segmentation of brain MR images
Abstract
Accurate brain tissue segmentation by intensity-based voxel classification of magnetic resonance (MR) images is complicated by partial volume (PV) voxels that contain a mixture of two or more tissue types. In this paper, we present a statistical framework for PV segmentation that encompasses and extends existing techniques. We start from a commonly used parametric statistical image model in which each voxel belongs to one single tissue type, and introduce an additional downsampling step that causes partial voluming along the borders between tissues. An expectation-maximization approach is used to simultaneously estimate the parameters of the resulting model and perform a PV classification. We present results on well-chosen simulated images and on real MR images of the brain, and demonstrate that the use of appropriate spatial prior knowledge not only improves the classifications, but is often indispensable for robust parameter estimation as well. We conclude that general robust PV segmentation of MR brain images requires statistical models that describe the spatial distribution of brain tissues more accurately than currently available models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Equation of State Calculations by Fast Computing Machines
Metropolis, N., Rosenbluth, A. W., Rosenbluth, M. N., Teller, A. H., & Teller, E. (1953) · The Journal of Chemical Physics · doi:10.1063/1.1699114 · Cited by 37,192
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
Beitrag zur Theorie des Ferromagnetismus
Ising, E. (1925) · Zeitschrift für Physik · doi:10.1007/bf02980577 · Cited by 3,871
On the Convergence Properties of the EM Algorithm
Wu, C. F. J. (1983) · The Annals of Statistics · doi:10.1214/aos/1176346060 · Cited by 3,269
Equation of state calculations by fast computing machines
Metropolis, N., Rosenbluth, A. W., Rosenbluth, M. N., Teller, A. H., & Teller, E. (1953) · doi:10.2172/4390578 · Cited by 1,701
A Monte Carlo Implementation of the EM Algorithm and the Poor Man's Data Augmentation Algorithms
Wei, G. C. G., & Tanner, M. A. (1990) · Journal of the American Statistical Association · doi:10.1080/01621459.1990.10474930 · Cited by 1,453
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Markov Random Field Modeling in Computer Vision
Li, S. Z. (1995) · Computer Science Workbench · doi:10.1007/978-4-431-66933-3 · Cited by 1,276
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
Self-citation
Cited by
Iglesias, J. E., Augustinack, J. C., Nguyen, K., Player, C. M., Player, A., Wright, M., Roy, N., Frosch, M. P., McKee, A. C., Wald, L. L., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.042 · Cited by 1,277
Self-citationWildenschild, D., & Sheppard, A. P. (2013) · Advances in Water Resources · doi:10.1016/j.advwatres.2012.07.018 · Cited by 1,239
Generalized Overlap Measures for Evaluation and Validation in Medical Image Analysis
Crum, W. R., Camara, O., & Hill, D. L. G. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880587 · Cited by 776
MRI Segmentation of the Human Brain: Challenges, Methods, and Applications
Despotović, I., Goossens, B., & Philips, W. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/450341 · Cited by 701
The optimal template effect in hippocampus studies of diseased populations
Avants, B. B., Yushkevich, P., Pluta, J., Minkoff, D., Korczykowski, M., Detre, J., & Gee, J. C. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.062 · Cited by 640
Metadata
- Authors
- Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-01
- Volume
- 22
- Issue
- 1
- Pages
- 105-119
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2161557710
- Cited by
- 281
- References
- 29
- FWCI
- 15.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A unifying framework for partial volume segmentation of brain MR images. https://app.cochat.ai/papers/10.1109/tmi.2002.806587
- The paper
- Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (2003). A unifying framework for partial volume segmentation of brain MR images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2002.806587
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.