Coupling dense and landmark-based approaches for nonrigid registration
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this paper, we investigate the introduction of cortical constraints for non rigid intersubject brain registration. We extract sulcal patterns with the active ribbon method, presented by Le Goualher et al. (1997). An energy based registration method (Hellier et al., 2001), which will be called photometric registration method in this paper, makes it possible to incorporate the matching of cortical sulci. The local sparse similarity and the photometric similarity are, thus, expressed in a unified framework. We show the benefits of cortical constraints on a database of 18 subjects, with global and local assessment of the registration. This new registration scheme has also been evaluated on functional magnetoencephalography data. We show that the anatomically constrained registration leads to a substantial reduction of the intersubject functional variability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190 · cited 1×
“We will not describe here the PCA technique, referring the reader to [6], [ 14 ], [33], [36], and [42] for further information.”
MethodSpatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
“Recently, registration methods using simultaneously both area-based and feature-based approaches have started to appear [85].”
MethodA reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“a) Additional Information Used as Soft Constraint: The Hellier and Barillot proposed to couple dense and landmark-based approaches for nonrigid brain registration in [272].”
MethodNon-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Dense image registration through MRFs and efficient linear programming
Glocker, B., Komodakis, N., Tziritas, G., Navab, N., & Paragios, N. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.03.006 · Cited by 427
Metadata
- Authors
- Hellier, P., & Barillot, C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-02
- Volume
- 22
- Issue
- 2
- Pages
- 217-227
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2105401362
- Cited by
- 122
- References
- 3
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coupling dense and landmark-based approaches for nonrigid registration. https://app.cochat.ai/papers/10.1109/tmi.2002.808365
- The paper
- Hellier, P., & Barillot, C. (2003). Coupling dense and landmark-based approaches for nonrigid registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2002.808365
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.