The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Platelets: a multiscale approach for recovering edges and surfaces in photon-limited medical imaging
Abstract
The nonparametric multiscale platelet algorithms presented in this paper, unlike traditional wavelet-based methods, are both well suited to photon-limited medical imaging applications involving Poisson data and capable of better approximating edge contours. This paper introduces platelets, localized functions at various scales, locations, and orientations that produce piece-wise linear image approximations, and a new multiscale image decomposition based on these functions. Platelets are well suited for approximating images consisting of smooth regions separated by smooth boundaries. For smoothness measured in certain Hölder classes, it is shown that the error of m-term platelet approximations can decay significantly faster than that of m-term approximations in terms of sinusoids, wavelets, or wedgelets. This suggests that platelets may outperform existing techniques for image denoising and reconstruction. Fast, platelet-based, maximum penalized likelihood methods for photon-limited image denoising, deblurring and tomographic reconstruction problems are developed. Because platelet decompositions of Poisson distributed images are tractable and computationally efficient, existing image reconstruction methods based on expectation-maximization type algorithms can be easily enhanced with platelet techniques. Experimental results suggest that platelet-based methods can outperform standard reconstruction methods currently in use in confocal microscopy, image restoration, and emission tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Ideal spatial adaptation by wavelet shrinkage
Donoho, D. L., & Johnstone, I. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.425 · Cited by 8,760
The EM Algorithm and Extensions
Kushary, D. (1998) · Technometrics · doi:10.1080/00401706.1998.10485534 · Cited by 5,417
Maximum Likelihood from Incomplete Data via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1976) · Cited by 4,517
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Translation-Invariant De-Noising
Coifman, R. R., & Donoho, D. L. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_9 · Cited by 1,914
Handbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Cited by
Dictionaries for Sparse Representation Modeling
Rubinstein, R., Bruckstein, A. M., & Elad, M. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2040551 · Cited by 1,306
Deep Learning Techniques for Inverse Problems in Imaging
Ongie, G., Jalal, A., Metzler, C. A., Baraniuk, R. G., Dimakis, A. G., & Willett, R. (2020) · IEEE Journal on Selected Areas in Information Theory · doi:10.1109/jsait.2020.2991563 · Cited by 577
Self-citationMa, J., & Plonka, G. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2009.935453 · Cited by 464
Restoration of Poissonian Images Using Alternating Direction Optimization
Figueiredo, M. A. T., & Bioucas-Dias, J. M. (2010) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2053941 · Cited by 372
Wavelets, Ridgelets, and Curvelets for Poisson Noise Removal
Zhang, B., Fadili, J. M., & Starck, J. L. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.924386 · Cited by 349
Optimal Inversion of the Anscombe Transformation in Low-Count Poisson Image Denoising
Makitalo, M., & Foi, A. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2056693 · Cited by 341
Poisson Noise Reduction with Non-local PCA
Salmon, J., Harmany, Z., Deledalle, C.-A., & Willett, R. (2014) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-013-0435-6 · Cited by 294
Self-citationThis is SPIRAL-TAP: Sparse Poisson Intensity Reconstruction ALgorithms—Theory and Practice
Harmany, Z. T., Marcia, R. F., & Willett, R. M. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2168410 · Cited by 286
Self-citationPatch-Based Nonlocal Functional for Denoising Fluorescence Microscopy Image Sequences
Boulanger, J., Kervrann, C., Bouthemy, P., Elbau, P., Sibarita, J.-B., & Salamero, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033991 · Cited by 281
Photon-Efficient Computational 3-D and Reflectivity Imaging With Single-Photon Detectors
Shin, D., Kirmani, A., Goyal, V. K., & Shapiro, J. H. (2015) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2015.2453093 · Cited by 255
The effects of multiview depth video compression on multiview rendering
Merkle, P., Morvan, Y., Smolic, A., Farin, D., Müller, K., de With, P. H. N., & Wiegand, T. (2009) · Signal Processing: Image Communication · doi:10.1016/j.image.2008.10.010 · Cited by 254
Metadata
- Authors
- Willett, R. M., & Nowak, R. D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-03
- Volume
- 22
- Issue
- 3
- Pages
- 332-350
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2140377889
- Cited by
- 279
- References
- 49
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.