The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Interpolation artifacts in multimodality image registration based on maximization of mutual information
Abstract
Mutual information (MI) is an increasingly popular match metric for multimodality image registration. However, its value is affected by interpolation, which may limit registration accuracy. The purpose of this study was to characterize the artifacts from eight interpolators and to investigate efficient strategies to overcome these artifacts. The interpolators were: 1) nearest neighbor; 2) linear; 3) cubic Catmull-Rom; 4) Hamming-windowed sinc; 5) partial volume; 6) NN with jittered sampling (JIT); 7) NN with histogram blurring (BLUR); and 8) NN with JIT and BLUR. The impact of interpolation on MI was evaluated in two dimensions over different translational and rotational misregistration. Interpolation caused spurious fluctuations in MI whenever the voxel grids had coinciding periodicities and were nearly aligned. The artifacts did not lessen by using intensity interpolators with wider support (e.g., cubic Catmull-Rom, Hamming-windowed sinc). PV could lead to either arch artifacts or inverted-arch artifacts, depending on the relative voxel sizes. Several strategies reduced artifacts and improved registration robustness: JIT, BLUR, avoiding an extreme number of intensity bins, and resampling the images in a rotated orientation with different relative voxel sizes (e.g., pi/3). These findings also apply to related methods, including normalized MI, joint entropy, and Hill's third moment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093 · cited 1×
“PV could lead to either arch artifacts or inverted-arch artifacts, depending on the relative voxel sizes.”
Background
Cited by
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Mutual-Information-Based Registration of TerraSAR-X and Ikonos Imagery in Urban Areas
Suri, S., & Reinartz, P. (2010) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2009.2034842 · Cited by 330
Vulnerabilities of radiomic signature development: The need for safeguards
Welch, M. L., McIntosh, C., Haibe-Kains, B., Milosevic, M. F., Wee, L., Dekker, A., Huang, S. H., Purdie, T. G., O'Sullivan, B., Aerts, H. J. W. L., et al. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.10.027 · Cited by 320
Zhao, F., Wang, P., Hendrich, K., Ugurbil, K., & Kim, S.-G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.013 · Cited by 266
Metadata
- Authors
- Tsao, J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-07
- Volume
- 22
- Issue
- 7
- Pages
- 854-864
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2170998104
- Cited by
- 158
- References
- 2
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.