The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Locating the optic nerve in a retinal image using the fuzzy convergence of the blood vessels
Abstract
We describe an automated method to locate the optic nerve in images of the ocular fundus. Our method uses a novel algorithm we call fuzzy convergence to determine the origination of the blood vessel network. We evaluate our method using 31 images of healthy retinas and 50 images of diseased retinas, containing such diverse symptoms as tortuous vessels, choroidal neovascularization, and hemorrhages that completely obscure the actual nerve. On this difficult data set, our method achieved 89% correct detection. We also compare our method against three simpler methods, demonstrating the performance improvement. All our images and data are freely available for other researchers to use in evaluating related methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Pattern Classification and Scene Analysis
Thompson, M., Duda, R. O., & Hart, P. E. (1974) · Leonardo · doi:10.2307/1573081 · Cited by 4,495
Image Processing, Analysis and Machine Vision
Sonka, M., Hlavac, V., & Boyle, R. (1993) · Springer eBooks · doi:10.1007/978-1-4899-3216-7 · Cited by 3,717
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Self-citationImage processing, analysis and machine vision
Dijkstra, T. (1994) · Neurocomputing · doi:10.1016/0925-2312(94)90073-6 · Cited by 1,805
Sinthanayothin, C., Boyce, J. F., Cook, H. L., & Williamson, T. H. (1999) · British Journal of Ophthalmology · doi:10.1136/bjo.83.8.902 · Cited by 778
Robust regression methods for computer vision: A review
Meer, P., Mintz, D., Rosenfeld, A., & Kim, D. Y. (1991) · International Journal of Computer Vision · doi:10.1007/bf00127126 · Cited by 638
A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
Tolias, Y. A., & Panas, S. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700738 · Cited by 365
Image processing analysis and machine vision [2nd ed.]
Sonka, M., Hlaváč, V., & Boyle, R. (1999) · Cited by 329
The human eye: structure and function
(2000) · Choice Reviews Online · doi:10.5860/choice.37-3340 · Cited by 294
Pinz, A., Bernogger, S., Datlinger, P., & Kruger, A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730405 · Cited by 233
A computer method of understanding ocular fundus images
Akita, K., & Kuga, H. (1982) · Pattern Recognition · doi:10.1016/0031-3203(82)90022-x · Cited by 186
The Human Eye: Structure and Function
Land, M. F. (1999) · Nature Medicine · doi:10.1038/15713 · Cited by 153
Goldbaum, M. H., Moezzi, S., Taylor, A., Chatterjee, S., Boyd, J., Hunter, E., & Jain, R. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1996.560760 · Cited by 132
Self-citation
Cited by
Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning
Kermany, D. S., Goldbaum, M., Cai, W., Valentim, C. C. S., Liang, H., Baxter, S. L., McKeown, A., Yang, G., Wu, X., Yan, F., et al. (2018) · Cell · doi:10.1016/j.cell.2018.02.010 · Cited by 4,842
Self-citationU-Net and Its Variants for Medical Image Segmentation: A Review of Theory and Applications
Siddique, N., Paheding, S., Elkin, C. P., & Devabhaktuni, V. (2021) · IEEE Access · doi:10.1109/access.2021.3086020 · Cited by 1,960
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Mendonca, A. M., & Campilho, A. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879955 · Cited by 921
Retinal Blood Vessel Segmentation Using Line Operators and Support Vector Classification
Ricci, E., & Perfetti, R. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.898551 · Cited by 818
Metadata
- Authors
- Hoover, A., & Goldbaum, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-08
- Volume
- 22
- Issue
- 8
- Pages
- 951-958
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2122644916
- Cited by
- 787
- References
- 15
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.