Guide-wire tracking during endovascular interventions
The DOI matches its Crossref record.
Abstract
A method is presented to extract and track the position of a guide wire during endovascular interventions under X-ray fluoroscopy. The method can be used to improve guide-wire visualization in low-quality fluoroscopic images and to estimate the position of the guide wire in world coordinates. A two-step procedure is utilized to track the guide wire in subsequent frames. First, a rough estimate of the displacement is obtained using a template-matching procedure. Subsequently, the position of the guide wire is determined by fitting a spline to a feature image. The feature images that have been considered enhance line-like structures on: 1) the original images; 2) subtraction images; and 3) preprocessed images in which coherent structures are enhanced. In the optimization step, the influence of the scale at which the feature is calculated and the additional value of using directional information is investigated. The method is evaluated on 267 frames from ten clinical image sequences. Using the automatic method, the guide wire could be tracked in 96% of the frames, with a similar accuracy to three observers, although the position of the tip was estimated less accurately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review
Rafii-Tari, H., Payne, C. J., & Yang, G.-Z. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0946-8 · Cited by 288
Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy
Ambrosini, P., Ruijters, D., Niessen, W. J., Moelker, A., & van Walsum, T. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66185-8_65 · Cited by 102
Self-citationMcLaughlin, R. A., Hipwell, J., Hawkes, D. J., Noble, J. A., Byrne, J. V., & Cox, T. C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852067 · Cited by 63
4D interventional device reconstruction from biplane fluoroscopy
Wagner, M., Schafer, S., Strother, C., & Mistretta, C. (2016) · Medical Physics · doi:10.1118/1.4941950 · Cited by 48
Metadata
- Authors
- Baert, S. A. M., Viergever, M. A., & Niessen, W. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-08
- Volume
- 22
- Issue
- 8
- Pages
- 965-972
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2132239611
- Cited by
- 102
- References
- 0
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guide-wire tracking during endovascular interventions. https://app.cochat.ai/papers/10.1109/tmi.2003.815904
- The paper
- Baert, S. A. M., Viergever, M. A., & Niessen, W. J. (2003). Guide-wire tracking during endovascular interventions. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2003.815904