CoChat

Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy

Open access
Ambrosini, Pierre, Ruijters, Daniel, Niessen, Wiro J., Moelker, Adriaan, van Walsum, Theo · 2017 · Lecture Notes in Computer Science

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Augmenting X-ray imaging with 3D roadmap to improve guidance is a common strategy. Such approaches benefit from automated analysis of the X-ray images, such as the automatic detection and tracking of instruments. In this paper, we propose a real-time method to segment the catheter and guidewire in 2D X-ray fluoroscopic sequences. The method is based on deep convolutional neural networks. The network takes as input the current image and the three previous ones, and segments the catheter and guidewire in the current image. Subsequently, a centerline model of the catheter is constructed from the segmented image. A small set of annotated data combined with data augmentation is used to train the network. We trained the method on images from 182 X-ray sequences from 23 different interventions. On a testing set with images of 55 X-ray sequences from 5 other interventions, a median centerline distance error of 0.2 mm and a median tip distance error of 0.9 mm was obtained. The segmentation of the instruments in 2D X-ray sequences is performed in a real-time fully-automatic manner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/978-3-319-66185-8_65

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 106

Metadata

Authors
Ambrosini, P., Ruijters, D., Niessen, W. J., Moelker, A., & van Walsum, T.
Affiliations
Erasmus MC (NL)
Corresponding author
Ambrosini, Pierre
Venue
Lecture Notes in Computer Science
Published
2017
Pages
577-585
ISSN
  • 0302-9743 (ISSN-L)
  • 1611-3349
OpenAlex
W2738072630
Cited by
102
References
20
Citations by year
2026: 6 · 2025: 12 · 2024: 11 · 2023: 6 · 2022: 13 · 2021: 18 · 2020: 14 · 2019: 12 · 2018: 8 · 2017: 2
FWCI
2.86
Type
conference paper
Language
en
Open access
Licence
Locations
  • Lecture notes in computer science (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
  • RePub (Erasmus University Rotterdam) (submittedVersion, other-oa)
  • arXiv (Cornell University)
  • Lecture notes in computer science
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
Keywords
X-ray fluoroscopy, real-time segmentation, convolutional neural networks, instrument tracking, interventional radiology, data augmentation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy. https://app.cochat.ai/papers/10.1007/978-3-319-66185-8_65
The paper
Ambrosini, P., Ruijters, D., Niessen, W. J., Moelker, A., & van Walsum, T. (2017). Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy. Lecture Notes in Computer Science. https://doi.org/10.1007/978-3-319-66185-8_65

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.