The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Fully Bayesian Spatio-Temporal Modeling of FMRI Data
Abstract
We present a fully Bayesian approach to modeling in functional magnetic resonance imaging (FMRI), incorporating spatio-temporal noise modeling and haemodynamic response function (HRF) modeling. A fully Bayesian approach allows for the uncertainties in the noise and signal modeling to be incorporated together to provide full posterior distributions of the HRF parameters. The noise modeling is achieved via a nonseparable space-time vector autoregressive process. Previous FMRI noise models have either been purely temporal, separable or modeling deterministic trends. The specific form of the noise process is determined using model selection techniques. Notably, this results in the need for a spatially nonstationary and temporally stationary spatial component. Within the same full model, we also investigate the variation of the HRF in different areas of the activation, and for different experimental stimuli. We propose a novel HRF model made up of half-cosines, which allows distinct combinations of parameters to represent characteristics of interest. In addition, to adaptively avoid over-fitting we propose the use of automatic relevance determination priors to force certain parameters in the model to zero with high precision if there is no evidence to support them in the data. We apply the model to three datasets and observe matter-type dependence of the spatial and temporal noise, and a negative correlation between activation height and HRF time to main peak (although we suggest that this apparent correlation may be due to a number of different effects).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Self-citationStatistical parametric maps in functional imaging: A general linear approach
Friston, K. J., Holmes, A. P., Worsley, K. J., Poline, J. ‐., Frith, C. D., & Frackowiak, R. S. J. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020402 · Cited by 9,688
Markov Chain Monte Carlo: Stochastic Simulation for Bayesian Inference, Second Edition
Gamerman, D., & Lopes, H. F. (2006) · doi:10.1201/9781482296426 · Cited by 1,097
Mackay, D. J. C. (1995) · Network Computation in Neural Systems · doi:10.1088/0954-898x/6/3/011 · Cited by 915
Cited by
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Self-citationSMITH, S., & NICHOLS, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.061 · Cited by 5,250
Self-citationMultilevel linear modelling for FMRI group analysis using Bayesian inference
Woolrich, M. W., Behrens, T. E. J., Beckmann, C. F., Jenkinson, M., & Smith, S. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.12.023 · Cited by 1,728
Self-citationMedical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
Changes in neuronal activation patterns in response to androgen deprivation therapy: a pilot study
Cherrier, M. M., Borghesani, P. R., Shelton, A. L., & Higano, C. S. (2010) · BMC Cancer · doi:10.1186/1471-2407-10-1 · Cited by 395
Metadata
- Authors
- Woolrich, M. W., Jenkinson, M., Brady, J. M., & Smith, S. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2004-02
- Volume
- 23
- Issue
- 2
- Pages
- 213-231
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2115450036
- Cited by
- 248
- References
- 4
- FWCI
- 13.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.