The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Measurement of Retinal Vessel Widths From Fundus Images Based on 2-D Modeling
Open accessAbstract
Changes in retinal vessel diameter are an important sign of diseases such as hypertension, arteriosclerosis and diabetes mellitus. Obtaining precise measurements of vascular widths is a critical and demanding process in automated retinal image analysis as the typical vessel is only a few pixels wide. This paper presents an algorithm to measure the vessel diameter to subpixel accuracy. The diameter measurement is based on a two-dimensional difference of Gaussian model, which is optimized to fit a two-dimensional intensity vessel segment. The performance of the method is evaluated against Brinchmann-Hansen's half height, Gregson's rectangular profile and Zhou's Gaussian model. Results from 100 sample profiles show that the presented algorithm is over 30% more precise than the compared techniques and is accurate to a third of a pixel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
Learning patterns of activity using real-time tracking
Stauffer, C., & Grimson, W. E. L. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.868677 · Cited by 3,248
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Fundus Photographic Risk Factors for Progression of Diabetic Retinopathy
(1991) · Ophthalmology · doi:10.1016/s0161-6420(13)38014-2 · Cited by 814
Wong, T. Y., Klein, R., Couper, D. J., Cooper, L. S., Shahar, E., Hubbard, L. D., Wofford, M. R., & Sharrett, A. R. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06253-5 · Cited by 781
Wong, T. Y., Klein, R., Klein, B. E. K., Tielsch, J. M., Hubbard, L., & Nieto, F. J. (2001) · Survey of Ophthalmology · doi:10.1016/s0039-6257(01)00234-x · Cited by 625
Girard, B. (2008) · Cited by 616
Event detection and analysis from video streams
Medioni, G., Cohen, I., Bremond, F., Hongeng, S., & Nevatia, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.946990 · Cited by 405
Cited by
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Mendonca, A. M., & Campilho, A. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879955 · Cited by 921
Retinal Blood Vessel Segmentation Using Line Operators and Support Vector Classification
Ricci, E., & Perfetti, R. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.898551 · Cited by 818
Retinal image analysis: Concepts, applications and potential
Patton, N., Aslam, T. M., MacGillivray, T., Deary, I. J., Dhillon, B., Eikelboom, R. H., Yogesan, K., & Constable, I. J. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2005.07.001 · Cited by 641
An Active Contour Model for Segmenting and Measuring Retinal Vessels
Al-Diri, B., Hunter, A., & Steel, D. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2017941 · Cited by 431
Self-citationFABC: Retinal Vessel Segmentation Using AdaBoost
Lupascu, C. A., Tegolo, D., & Trucco, E. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2052282 · Cited by 352
An approach to localize the retinal blood vessels using bit planes and centerline detection
Fraz, M. M., Barman, S. A., Remagnino, P., Hoppe, A., Basit, A., Uyyanonvara, B., Rudnicka, A. R., & Owen, C. G. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.08.009 · Cited by 340
Fast Retinal Vessel Detection and Measurement Using Wavelets and Edge Location Refinement
Bankhead, P., Scholfield, C. N., McGeown, J. G., & Curtis, T. M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032435 · Cited by 337
Retinal Vessel Centerline Extraction Using Multiscale Matched Filters, Confidence and Edge Measures
Sofka, M., & Stewart, C. V. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.884190 · Cited by 334
General Retinal Vessel Segmentation Using Regularization-Based Multiconcavity Modeling
Lam, B. S. Y., Gao, Y., & Liew, A. W.-C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2043259 · Cited by 275
Metadata
- Authors
- Lowell, J., Hunter, A., Steel, D., Basu, A., Ryder, R., & Kennedy, R. L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2004-10
- Volume
- 23
- Issue
- 10
- Pages
- 1196-1204
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2155122478
- Cited by
- 255
- References
- 22
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.