The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
A Method for Modeling Noise in Medical Images
Abstract
We have developed a method to study the statistical properties of the noise found in various medical images. The method is specifically designed for types of noise with uncorrelated fluctuations. Such signal fluctuations generally originate in the physical processes of imaging rather than in the tissue textures. Various types of noise (e.g., photon, electronics, and quantization) often contribute to degrade medical images; the overall noise is generally assumed to be additive with a zero-mean, constant-variance Gaussian distribution. However, statistical analysis suggests that the noise variance could be better modeled by a nonlinear function of the image intensity depending on external parameters related to the image acquisition protocol. We present a method to extract the relationship between an image intensity and the noise variance and to evaluate the corresponding parameters. The method was applied successfully to magnetic resonance images with different acquisition sequences and to several types of X-ray images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
The Essential Physics of Medical Imaging
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., Boone, J. M., & Goldschmidt, E. J. (2003) · Medical Physics · doi:10.1118/1.1585033 · Cited by 1,987
Understanding robust and exploratory data analysis
Hoaglin, D. C., Mosteller, F. C., & Tukey, J. W. (1983) · Wiley eBooks · Cited by 1,906
Cleveland, W. S. (1993) · Cited by 1,698
Understanding Robust and Exploratory Data Analysis.
Collett, D., Hoaglin, D. C., Mosteller, F., & Tukey, J. W. (1984) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2981753 · Cited by 1,154
The Essential Physics of Medical Imaging
(2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1073-1 · Cited by 408
Understanding Robust and Exploratory Data Analysis.
Healy, M. J. R., Hoaglin, D. C., Mosteller, F., & Tukey, J. W. (1983) · Biometrics · doi:10.2307/2531362 · Cited by 230
The Essential Physics of Medical Imaging, 2nd ed.
Ravenel, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.3.1800596 · Cited by 229
Cited by
A review on CT image noise and its denoising
Diwakar, M., & Kumar, M. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.01.010 · Cited by 416
A review on medical image denoising algorithms
Mohd Sagheer, S. V., & George, S. N. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102036 · Cited by 316
McLaughlin, R. A., Hipwell, J., Hawkes, D. J., Noble, J. A., Byrne, J. V., & Cox, T. C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852067 · Cited by 63
Metadata
- Authors
- Gravel, P., Beaudoin, G., & DeGuise, J. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2004-10
- Volume
- 23
- Issue
- 10
- Pages
- 1221-1232
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2137969878
- Cited by
- 308
- References
- 13
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.