Analysis of 3-D Myocardial Motion in Tagged MR Images Using Nonrigid Image Registration
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Tagged magnetic resonance imaging (MRI) is unique in its ability to noninvasively image the motion and deformation of the heart in vivo, but one of the fundamental reasons limiting its use in the clinical environment is the absence of automated tools to derive clinically useful information from tagged MR images. In this paper, we present a novel and fully automated technique based on nonrigid image registration using multilevel free-form deformations (MFFDs) for the analysis of myocardial motion using tagged MRI. The novel aspect of our technique is its integrated nature for tag localization and deformation field reconstruction using image registration and voxel based similarity measures. To extract the motion field within the myocardium during systole we register a sequence of images taken during systole to a set of reference images taken at end-diastole, maximizing the normalized mutual information between the images. We use both short-axis and long-axis images of the heart to estimate the full four-dimensional motion field within the myocardium. We also present validation results from data acquired from twelve volunteers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 2×
“to apply the algorithm in [15] for motion tracking in cardiac MR images several modifications are necessary.”
MethodSelf-citationAn overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180 · cited 1×
“of the normalized mutual information [16] between the registered SA and LA images.”
BackgroundHuman heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430 · cited 5×
“A number of methods have been proposed in recent years to help with this task including active contour models and B-spline surface models [5]–[8], deformable models [9], optical flow methods [10], [11], and harmonic phase (HARP) MRI [12], [13], but many need substantial user intervention and human interaction.”
BackgroundInfluentialHeart wall motion: improved method of spatial modulation of magnetization for MR imaging.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.172.2.2748813 · Cited by 597 · cited 1×
“Tagged magnetic resonance imaging (MRI) [2], [3] is a well known technique which can be used to obtain regional information about the deformation of the left ventricle (LV), and thus potentially help to diagnose CVDs.”
BackgroundCardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging
Osman, N. F., Kerwin, W. S., McVeigh, E. R., & Prince, J. L. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1048::aid-mrm9>3.0.co;2-m · Cited by 588 · cited 5×
“A number of methods have been proposed in recent years to help with this task including active contour models and B-spline surface models [5]–[8], deformable models [9], optical flow methods [10], [11], and harmonic phase (HARP) MRI [12], [13], but many need substantial user intervention and human interaction.”
MethodInfluentialThree-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533 · cited 1×
“An excellent review of the many techniques developed for three-dimensional (3-D) cardiac image analysis is given in Frangi et al. [ 14 ].”
MethodImaging heart motion using harmonic phase MRI
Osman, N. F., McVeigh, E. R., & Prince, J. L. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845177 · Cited by 430 · cited 1×
“A number of methods have been proposed in recent years to help with this task including active contour models and B-spline surface models [5]–[8], deformable models [9], optical flow methods [10], [11], and harmonic phase (HARP) MRI [12], [13], but many need substantial user intervention and human interaction.”
MethodSchnabel, J. A., Rueckert, D., Quist, M., Blackall, J. M., Castellano-Smith, A. D., Hartkens, T., Penney, G. P., Hall, W. A., Liu, H., Truwit, C. L., et al. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45468-3_69 · Cited by 355 · cited 1×
“[17] where the transformation is represented as the sum of a series of local FFDs:”
BackgroundSelf-citationTracking and finite element analysis of stripe deformation in magnetic resonance tagging
Young, A. A., Kraitchman, D. L., Dougherty, L., & Axel, L. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414605 · Cited by 239 · cited 1×
“A number of methods have been proposed in recent years to help with this task including active contour models and B-spline surface models [5]–[8], deformable models [9], optical flow methods [10], [11], and harmonic phase (HARP) MRI [12], [13], but many need substantial user intervention and human interaction.”
MethodMotion estimation from tagged MR image sequences
Prince, J. L., & McVeigh, E. R. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141648 · Cited by 208
Cited by
Spatiotemporal motion estimation for respiratory‐correlated imaging of the lungs
Vandemeulebroucke, J., Rit, S., Kybic, J., Clarysse, P., & Sarrut, D. (2011) · Medical Physics · doi:10.1118/1.3523619 · Cited by 172
“(13) ∂f/∂x is found by deriving (3), while ∂Tst/∂cj,l can be calculated considering 259 (11).”
Background
Metadata
- Authors
- Chandrashekara, R., Mohiaddin, R. H., & Rueckert, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2004-10
- Volume
- 23
- Issue
- 10
- Pages
- 1245-1250
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2149267107
- Cited by
- 172
- References
- 13
- FWCI
- 14.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of 3-D Myocardial Motion in Tagged MR Images Using Nonrigid Image Registration. https://app.cochat.ai/papers/10.1109/tmi.2004.834607
- The paper
- Chandrashekara, R., Mohiaddin, R. H., & Rueckert, D. (2004). Analysis of 3-D Myocardial Motion in Tagged MR Images Using Nonrigid Image Registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2004.834607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.