The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Rapid gridding reconstruction with a minimal oversampling ratio
Abstract
Reconstruction of magnetic resonance images from data not falling on a Cartesian grid is a Fourier inversion problem typically solved using convolution interpolation, also known as gridding. Gridding is simple and robust and has parameters, the grid oversampling ratio and the kernel width, that can be used to trade accuracy for computational memory and time reductions. We have found that significant reductions in computation memory and time can be obtained while maintaining high accuracy by using a minimal oversampling ratio, from 1.125 to 1.375, instead of the typically employed grid oversampling ratio of two. When using a minimal oversampling ratio, appropriate design of the convolution kernel is important for maintaining high accuracy. We derive a simple equation for choosing the optimal Kaiser-Bessel convolution kernel for a given oversampling ratio and kernel width. As well, we evaluate the effect of presampling the kernel, a common technique used to reduce the computation time, and find that using linear interpolation between samples adds negligible error with far less samples than is necessary with nearest-neighbor interpolation. We also develop a new method for choosing the optimal presampled kernel. Using a minimal oversampling ratio and presampled kernel, we are able to perform a three-dimensional (3-D) reconstruction in one-eighth the time and requiring one-third the computer memory versus using an oversampling ratio of two and a Kaiser-Bessel convolution kernel, while maintaining the same level of accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Using SeDuMi 1.02, A Matlab toolbox for optimization over symmetric cones
Sturm, J. F. (1999) · Optimization Methods and Software · doi:10.1080/10556789908805766 · Cited by 7,377
Applications of second-order cone programming
Lobo, M. S., Vandenberghe, L., Boyd, S., & Lebret, H. (1998) · Linear Algebra and its Applications · doi:10.1016/s0024-3795(98)10032-0 · Cited by 2,401
Nonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
Self-citationFast Fourier Transforms for Nonequispaced Data
Dutt, A., & Rokhlin, V. (1993) · SIAM Journal on Scientific Computing · doi:10.1137/0914081 · Cited by 918
Accelerating the Nonuniform Fast Fourier Transform
Greengard, L., & Lee, J.-Y. (2004) · SIAM Review · doi:10.1137/s003614450343200x · Cited by 727
A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer Tomography
O'Sullivan, J. D. (1985) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1985.4307723 · Cited by 482
Sampling density compensation in MRI: Rationale and an iterative numerical solution
Pipe, J. G., & Menon, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199901)41:1<179::aid-mrm25>3.0.co;2-v · Cited by 350
Resampling of data between arbitrary grids using convolution interpolation
Rasche, V., Proksa, R., Sinkus, R., Bornert, P., & Eggers, H. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774166 · Cited by 227
The gridding method for image reconstruction by Fourier transformation
Schomberg, H., & Timmer, J. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414625 · Cited by 189
Reconstruction in diffraction ultrasound tomography using nonuniform FFT
Bronstein, M. M., Bronstein, A. M., Zibulevsky, M., & Azhari, H. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806423 · Cited by 107
An efficient Fourier method for 3-D radon inversion in exact cone-beam CT reconstruction
Schaller, S., Flohr, T. G., & Steffen, P. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700736 · Cited by 39
Adaptive Tracking of Non-Rigid Objects Based on Color Histograms and Automatic Parameter Selection
Jacquot, A., Sturm, P. F., & Ruch, O. (2005) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/acvmot.2005.19 · Cited by 33
Moriguchi, H., & Duerk, J. L. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10692 · Cited by 26
Cited by
Block, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
Self-citationMotion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774
Prospective motion correction in brain imaging: A review
Maclaren, J., Herbst, M., Speck, O., & Zaitsev, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24314 · Cited by 401
Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391
Self-citation
Metadata
- Authors
- Beatty, P. J., Nishimura, D. G., & Pauly, J. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-06
- Volume
- 24
- Issue
- 6
- Pages
- 799-808
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2135730039
- Cited by
- 333
- References
- 14
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.