A system for real-time XMR guided cardiovascular intervention
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sliding table XMR configuration. The aim of our recent work was to extend our technique by providing an improved calibration stage, real-time guidance during cardiovascular catheterization procedures, and further off-line analysis for mapping cardiac electrical data to patient anatomy. Specially designed optical trackers and a dedicated calibration object have resulted in a single calibration step that can be efficiently checked and updated before each procedure. An X-ray distortion model has been implemented that allows for distortion correction for arbitrary c-arm orientations. During procedures, the guidance system provides a real-time combined MR/X-ray image display consisting of live X-ray images with registered recently acquired MR derived anatomy. It is also possible to reconstruct the location of catheters seen during X-ray imaging in the MR derived patient anatomy. We have applied our registration technique to 13 cardiovascular catheterization procedures. Our system has been used for the real-time guidance of ten radiofrequency ablations and one aortic stent implantation. We demonstrate the real-time guidance using two exemplar cases. In a further two cases we show how off-line analysis of registered image data, acquired during electrophysiology study procedures, has been used to map cardiac electrical measurements to patient anatomy for two different types of mapping catheters. The cardiologists that have used the guidance system suggest that real-time XMR guidance could have substantial value in difficult interventional and electrophysiological procedures, potentially reducing procedure time and delivered radiation dose. Also, the ability to map measured electrical data to patient specific anatomy provides improved visualization and a path to investigation of cardiac electromechanical models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Implicit fairing of irregular meshes using diffusion and curvature flow
Desbrun, M., Meyer, M., Schröder, P., & Barr, A. H. (1999) · Proceedings of the 26th annual conference on Computer graphics and interactive techniques - SIGGRAPH '99 · doi:10.1145/311535.311576 · Cited by 1,538 · cited 1×
“The dynamics equation is solved using an internal energy smoothing the surface by minimizing the area locally, thus the curvature, as proposed in [ 21 ].”
MethodCardiac catheterisation guided by MRI in children and adults with congenital heart disease
Razavi, R., Hill, D. L., Keevil, S. F., Miquel, M. E., Muthurangu, V., Hegde, S., Rhode, K., Barnett, M., van Vaals, J., Hawkes, D. J., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14956-2 · Cited by 336 · cited 1×
“Many procedures have been successfully carried out using MR guidance in animal models [3], [4] and our group has reported the first clinical use of MR catheter guidance [ 5 ].”
MethodSelf-citationA review of deformable surfaces: topology, geometry and deformation
Montagnat, J., Delingette, H., & Ayache, N. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(01)00064-6 · Cited by 274 · cited 1×
“This was performed using the deformable surfaces framework [20], where the surface to be deformed evolves under the influence of two enerFig.”
MethodNon-contact left ventricular endocardial mapping in cardiac resynchronisation therapy
Lambiase, P. D., Rinaldi, C. A., Hauck, J., Mobb, M., Elliott, D., Mohammad, S., Gill, J. S., & Bucknall, C. A. (2003) · Heart · doi:10.1136/heart.90.1.44 · Cited by 146
Self-citationRegistration and tracking to integrate X-ray and MR images in an XMR facility
Rhode, K., Hill, D., Edwards, P., Hipwell, J. H., Rueckert, D., Sanchez-Ortiz, G. I., Hegde, S. R., Rahunathan, V., & Razavi, R. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819275 · Cited by 133 · cited 4×
“We have previously reported and validated such a technique using the sliding table XMR system configuration [6], [7].”
MethodInfluentialSelf-citationFahrig, R., Moreau, M., & Holdsworth, D. W. (1997) · Medical Physics · doi:10.1118/1.598013 · Cited by 131 · cited 1×
“It was shown in [ 9 ] that using higher order polynomials significantly improves the residual error up to fifth-order but using higher orders than this has no statistical improvement.”
MethodClinical Experience With a Novel Multielectrode Basket Catheter in Right Atrial Tachycardias
Schmitt, C., Zrenner, B., Schneider, M., KARCH, M. R., Ndrepepa, G., Deisenhofer, I., Weyerbrock, S., Schreieck, J., & Schömig, A. (1999) · Circulation · doi:10.1161/01.cir.99.18.2414 · Cited by 94
Globally constrained deformable models for 3D object reconstruction
Montagnat, J., & Delingette, H. (1998) · Signal Processing · doi:10.1016/s0165-1684(98)00143-1 · Cited by 71 · cited 1×
“closest point algorithm, as proposed by [16].”
Predictive (un)distortion model and 3-D reconstruction by biplane snakes
Cañero, C., Vilariño, F., Mauri, J., & Radeva, P. I. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804421 · Cited by 63 · cited 2×
“These results compare well with previously published work [8]–[11].”
MethodResultMagnetic Resonance–Guided Cardiac Catheterization in a Swine Model of Atrial Septal Defect
Schalla, S. M., Saeed, M., Higgins, C. B., Martin, A. J., Weber, O. M., & Moore, P. (2003) · Circulation · doi:10.1161/01.cir.0000089368.15818.ac · Cited by 60 · cited 1×
“Many procedures have been successfully carried out using MR guidance in animal models [3], [4] and our group has reported the first clinical use of MR catheter guidance [5].”
Method
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“…MR imaging systems gradient field using two X-rays from the publically available spine phantom image (XMR) has opened up new strategies for registering 3D and 2D images with the goal of augmenting a recently acquired MR image with live X-ray images (Rhode et al., 2003, 2005; Miquel et al., 2006).”
MethodImage-Guided Interventions: Technology Review and Clinical Applications
Cleary, K., & Peters, T. M. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105249 · Cited by 453
Computational models in cardiology
Niederer, S. A., Lumens, J., & Trayanova, N. A. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0104-y · Cited by 434
Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review
Rafii-Tari, H., Payne, C. J., & Yang, G.-Z. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0946-8 · Cited by 288
Metadata
- Authors
- Rhode, K. S., Sermesant, M., Brogan, D., Hegde, S., Hipwell, J., Lambiase, P., Rosenthal, E., Bucknall, C., Qureshi, S. A., Gill, J. S., Razavi, R., & Hill, D. L. G.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-11
- Volume
- 24
- Issue
- 11
- Pages
- 1428-1440
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2104443850
- Cited by
- 168
- References
- 14
- FWCI
- 17.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.