A system for real-time XMR guided cardiovascular intervention

Rhode, K.S., Sermesant, M., Brogan, D., Hegde, S., Hipwell, J., Lambiase, P., Rosenthal, E., Bucknall, C., Qureshi, S.A., Gill, J.S., Razavi, R., Hill, D.L.G. · 2005 · IEEE Transactions on Medical Imaging
Cited by 168

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sliding table XMR configuration. The aim of our recent work was to extend our technique by providing an improved calibration stage, real-time guidance during cardiovascular catheterization procedures, and further off-line analysis for mapping cardiac electrical data to patient anatomy. Specially designed optical trackers and a dedicated calibration object have resulted in a single calibration step that can be efficiently checked and updated before each procedure. An X-ray distortion model has been implemented that allows for distortion correction for arbitrary c-arm orientations. During procedures, the guidance system provides a real-time combined MR/X-ray image display consisting of live X-ray images with registered recently acquired MR derived anatomy. It is also possible to reconstruct the location of catheters seen during X-ray imaging in the MR derived patient anatomy. We have applied our registration technique to 13 cardiovascular catheterization procedures. Our system has been used for the real-time guidance of ten radiofrequency ablations and one aortic stent implantation. We demonstrate the real-time guidance using two exemplar cases. In a further two cases we show how off-line analysis of registered image data, acquired during electrophysiology study procedures, has been used to map cardiac electrical measurements to patient anatomy for two different types of mapping catheters. The cardiologists that have used the guidance system suggest that real-time XMR guidance could have substantial value in difficult interventional and electrophysiological procedures, potentially reducing procedure time and delivered radiation dose. Also, the ability to map measured electrical data to patient specific anatomy provides improved visualization and a path to investigation of cardiac electromechanical models.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2005.856731

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

Metadata

Authors
Rhode, K. S., Sermesant, M., Brogan, D., Hegde, S., Hipwell, J., Lambiase, P., Rosenthal, E., Bucknall, C., Qureshi, S. A., Gill, J. S., Razavi, R., & Hill, D. L. G.
Venue
IEEE Transactions on Medical Imaging
Published
2005-11
Volume
24
Issue
11
Pages
1428-1440
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2104443850
Cited by
168
References
14
FWCI
17.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.