Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Super-resolution in PET imaging

Kennedy, J.A., Israel, O., Frenkel, A., Bar-Shalom, R., Haim Azhari·2006·IEEE Transactions on Medical Imaging

Abstract

This paper demonstrates a super-resolution method for improving the resolution in clinical positron emission tomography (PET) scanners. Super-resolution images were obtained by combining four data sets with spatial shifts between consecutive acquisitions and applying an iterative algorithm. Super-resolution attenuation corrected PET scans of a phantom were obtained using the two-dimensional and three-dimensional (3-D) acquisition modes of a clinical PET/computed tomography (CT) scanner (Discovery LS, GEMS). In a patient study, following a standard 18F-FDG PET/CT scan, a super-resolution scan around one small lesion was performed using axial shifts without increasing the patient radiation exposure. In the phantom study, smaller features (3 mm) could be resolved axially with the super-resolution method than without (6 mm). The super-resolution images had better resolution than the original images and provided higher contrast ratios in coronal images and in 3-D acquisition transaxial images. The coronal super-resolution images had superior resolution and contrast ratios compared to images reconstructed by merely interleaving the data to the proper axial location. In the patient study, super-resolution reconstructions displayed a more localized 18F-FDG uptake. A new approach for improving the resolution of PET images using a super-resolution method has been developed and experimentally confirmed, employing a clinical scanner. The improvement in axial resolution requires no changes in hardware.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2005.861705

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Kennedy, J. A., Israel, O., Frenkel, A., Bar-Shalom, R., & Azhari, H.
Venue
IEEE Transactions on Medical Imaging
Published
2006-02
Volume
25
Issue
2
Pages
137-147
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2111249617
Cited by
188
References
0
FWCI
6.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Super-resolution in PET imaging. https://app.cochat.ai/papers/10.1109/tmi.2005.861705
The paper
Kennedy, J. A., Israel, O., Frenkel, A., Bar-Shalom, R., & Azhari, H. (2006). Super-resolution in PET imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.861705

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.