The DOI matches its Crossref record.
Super-resolution in PET imaging
Abstract
This paper demonstrates a super-resolution method for improving the resolution in clinical positron emission tomography (PET) scanners. Super-resolution images were obtained by combining four data sets with spatial shifts between consecutive acquisitions and applying an iterative algorithm. Super-resolution attenuation corrected PET scans of a phantom were obtained using the two-dimensional and three-dimensional (3-D) acquisition modes of a clinical PET/computed tomography (CT) scanner (Discovery LS, GEMS). In a patient study, following a standard 18F-FDG PET/CT scan, a super-resolution scan around one small lesion was performed using axial shifts without increasing the patient radiation exposure. In the phantom study, smaller features (3 mm) could be resolved axially with the super-resolution method than without (6 mm). The super-resolution images had better resolution than the original images and provided higher contrast ratios in coronal images and in 3-D acquisition transaxial images. The coronal super-resolution images had superior resolution and contrast ratios compared to images reconstructed by merely interleaving the data to the proper axial location. In the patient study, super-resolution reconstructions displayed a more localized 18F-FDG uptake. A new approach for improving the resolution of PET images using a super-resolution method has been developed and experimentally confirmed, employing a clinical scanner. The improvement in axial resolution requires no changes in hardware.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Super-resolution: a comprehensive survey
Nasrollahi, K., & Moeslund, T. B. (2014) · Machine Vision and Applications · doi:10.1007/s00138-014-0623-4 · Cited by 684
Dopamine and glutamate in schizophrenia: biology, symptoms and treatment
McCutcheon, R. A., Krystal, J. H., & Howes, O. D. (2020) · World Psychiatry · doi:10.1002/wps.20693 · Cited by 612
Super-Resolution in Medical Imaging
Greenspan, H. (2008) · The Computer Journal · doi:10.1093/comjnl/bxm075 · Cited by 564
Image super-resolution: the techniques, applications, and future
Yue, L., Shen, H., Li, J., Yuan, Q., Zhang, H., & Zhang, L. (2016) · Signal Processing · doi:10.1016/j.sigpro.2016.05.002 · Cited by 554
Metadata
- Authors
- Kennedy, J. A., Israel, O., Frenkel, A., Bar-Shalom, R., & Azhari, H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-02
- Volume
- 25
- Issue
- 2
- Pages
- 137-147
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2111249617
- Cited by
- 188
- References
- 0
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Super-resolution in PET imaging. https://app.cochat.ai/papers/10.1109/tmi.2005.861705
- The paper
- Kennedy, J. A., Israel, O., Frenkel, A., Bar-Shalom, R., & Azhari, H. (2006). Super-resolution in PET imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.861705
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.