The DOI matches its Crossref record.
MDCT-based 3-D texture classification of emphysema and early smoking related lung pathologies
Abstract
Our goal is to enhance the ability to differentiate normal lung from subtle pathologies via multidetector row CT (MDCT) by extending a two-dimensional (2-D) texturebased tissue classification [adaptive multiple feature method (AMFM)] to use three-dimensional (3-D) texture features. We performed MDCT on 34 humans and classified volumes of interest (VOIs) in the MDCT images into five categories: EC, emphysema in severe chronic obstructive pulmonary disease (COPD); MC, mild emphysema in mild COPD; NC, normal appearing lung in mild COPD; NN, normal appearing lung in normal nonsmokers; and NS, normal appearing lung in normal smokers. COPD severity was based upon pulmonary function tests (PFTs). Airways and vessels were excluded from VOIs; 24 3-D texture features were calculated; and a Bayesian classifier was used for discrimination. A leave-one-out method was employed for validation. Sensitivity of the four-class classification in the form of 3-D/2-D was: EC: 85%/71%, MC: 90%/82%; NC: 88%/50%; NN: 100%/60%. Sensitivity and specificity for NN using a two-class classification of NN and NS in the form of 3-D/2-D were: 99%/72% and 100%/75%, respectively. We conclude that 3-D AMFM analysis of lung parenchyma improves discrimination compared to 2-D AMFM of the same VOIs. Furthermore, our results suggest that the 3-D AMFM may provide a means of discriminating subtle differences between smokers and nonsmokers both with normal PFTs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Self-citationHsia, C. C. W., Hyde, D. M., Ochs, M., & Weibel, E. R. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200809-1522st · Cited by 902
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Radiomics: a new application from established techniques
Parekh, V., & Jacobs, M. A. (2016) · Expert Review of Precision Medicine and Drug Development · doi:10.1080/23808993.2016.1164013 · Cited by 369
Quantitative Analysis of Pulmonary Emphysema Using Local Binary Patterns
Srensen, L., Shaker, S. B., & de Bruijne, M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2038575 · Cited by 367
Metadata
- Authors
- Xu, Y., Sonka, M., McLennan, G., Guo, J., & Hoffman, E. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-04
- Volume
- 25
- Issue
- 4
- Pages
- 464-475
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2153364064
- Cited by
- 232
- References
- 0
- FWCI
- 11.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MDCT-based 3-D texture classification of emphysema and early smoking related lung pathologies. https://app.cochat.ai/papers/10.1109/tmi.2006.870889
- The paper
- Xu, Y., Sonka, M., McLennan, G., Guo, J., & Hoffman, E. A. (2006). MDCT-based 3-D texture classification of emphysema and early smoking related lung pathologies. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2006.870889
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.