An electromechanical model of the heart for image analysis and simulation
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
This paper presents a new three-dimensional electromechanical model of the two cardiac ventricles designed both for the simulation of their electrical and mechanical activity, and for the segmentation of time series of medical images. First, we present the volumetric biomechanical models built. Then the transmembrane potential propagation is simulated, based on FitzHugh-Nagumo reaction-diffusion equations. The myocardium contraction is modeled through a constitutive law including an electromechanical coupling. Simulation of a cardiac cycle, with boundary conditions representing blood pressure and volume constraints, leads to the correct estimation of global and local parameters of the cardiac function. This model enables the introduction of pathologies and the simulation of electrophysiology interventions. Moreover, it can be used for cardiac image analysis. A new proactive deformable model of the heart is introduced to segment the two ventricles in time series of cardiac images. Preliminary results indicate that this proactive model, which integrates a priori knowledge on the cardiac anatomy and on its dynamical behavior, can improve the accuracy and robustness of the extraction of functional parameters from cardiac images even in the presence of noisy or sparse data. Such a model also allows the simulation of cardiovascular pathologies in order to test therapy strategies and to plan interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191 · cited 1×
“3http://www-rocq.inria.fr/gamma/ghs3d/ghs.html”
Zienkiewicz, O. C. (1989) · Cited by 14,802
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104 · cited 1×
“Then, a triangulated surface of the myocardium is obtained using the marching cubes method [ 43 ], and is decimated to the required size (typically 7 000 nodes for accurate simulation, or 1 500 nodes for the segmentation of cardiac images).”
MethodMarching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Impulses and Physiological States in Theoretical Models of Nerve Membrane
FitzHugh, R. (1961) · Biophysical Journal · doi:10.1016/s0006-3495(61)86902-6 · Cited by 6,258 · cited 1×
“3http://www-rocq.inria.fr/gamma/ghs3d/ghs.html”
Deformable models in medical image analysis: a survey
McInerney, T., & Terzopoulos, D. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80007-7 · Cited by 1,913
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Total Excitation of the Isolated Human Heart
DURRER, D., VAN DAM, R. T., FREUD, G. E., JANSE, M. J., MEIJLER, F. L., & ARZBAECHER, R. C. (1970) · Circulation · doi:10.1161/01.cir.41.6.899 · Cited by 1,777 · cited 1×
“[67] which present illustrations of the isochrones in an isolated human heart, paced from the special conducting system (the version of these measures presented in Fig.”
MethodLuo, C. H., & Rudy, Y. (1991) · Circulation Research · doi:10.1161/01.res.68.6.1501 · Cited by 1,468
Reconstruction of the action potential of ventricular myocardial fibres
Beeler, G. W., & Reuter, H. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011853 · Cited by 1,421
A simple two-variable model of cardiac excitation
Aliev, R. R., & Panfilov, A. V. (1996) · Chaos, Solitons & Fractals · doi:10.1016/0960-0779(95)00089-5 · Cited by 786 · cited 2×
“Aliev and Panfilov developed a modified version of the FitzHugh-Nagumo equations adapted to the dynamics of the cardiac electrical potential [51] (1) where is a normalized transmembrane potential and is a secondary variable for the repolarization. and control the repolarization, and the stimulation…”
BackgroundMethodAsymmetric redirection of flow through the heart
Kilner, P. J., Yang, G.-Z., Wilkes, A. J., Mohiaddin, R. H., Firmin, D. N., & Yacoub, M. H. (2000) · Nature · doi:10.1038/35008075 · Cited by 715
Mathematical model of geometry and fibrous structure of the heart
Nielsen, P. M., Le Grice, I. J., Smaill, B. H., & Hunter, P. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.4.h1365 · Cited by 657
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533 · cited 2×
“In the classification proposed by Frangi et al. review [15], the presented method would fit in the “continuous volumetric model” class.”
MethodResultStatistical models of appearance for medical image analysis and computer vision:
Cootes, T. F., & Taylor, C. J. (2001) · SPIE Proceedings · doi:10.1117/12.431093 · Cited by 429 · cited 1×
“These models are now developed for spatio-temporal data.”
BackgroundTotal arterial inertance as the fourth element of the windkessel model
Stergiopulos, N., Westerhof, B. E., & Westerhof, N. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.1.h81 · Cited by 408 · cited 1×
“pressure and blood flow in the arteries in order to compute the after-load [75], [76].”
MethodDetermination of a Constitutive Relation for Passive Myocardium: I. A New Functional Form
Humphrey, J. D., Strumpf, R. K., & Yin, F. C. P. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891193 · Cited by 352
Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical model
Ferrant, M., Nabavi, A., Macq, B., Jolesz, F. A., Kikinis, R., & Warfield, S. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974933 · Cited by 339
Noble, D., Varghese, A., Kohl, P. K., & Noble, P. J. (1998) · PubMed · Cited by 319
Hunter, P. J., Pullan, A. J., & Smaill, B. H. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121537 · Cited by 291
Silbernagl, S., Despopoulos, A., et al. (2008) · Thieme eBooks · doi:10.1055/b-005-148941 · Cited by 281
A review of deformable surfaces: topology, geometry and deformation
Montagnat, J., Delingette, H., & Ayache, N. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(01)00064-6 · Cited by 274 · cited 1×
“The use of deformable models [17] is mainly limited to deformable surfaces [18], with an extension to spatial and time constraints [19].”
MethodSelf-citationAutomated segmentation of the left ventricle in cardiac MRI
KAUS, M., BERG, J., WEESE, J., NIESSEN, W., & PEKAR, V (2004) · Medical Image Analysis · doi:10.1016/j.media.2004.06.015 · Cited by 242
Sagawa, K. (1990) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(90)91459-k · Cited by 229
Estimation of 3D left ventricular deformation from echocardiography
Papademetris, X., Sinusas, A. J., Dione, D. P., & Duncan, J. S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00022-0 · Cited by 208 · cited 1×
“It can be anatomical information, like fiber orientation, or mechanical behavior, to offer more reliable estimations of heart kinematics [ 34 ]‐[38].”
Background4D deformable models with temporal constraints: application to 4D cardiac image segmentation
Montagnat, J., & Delingette, H. (2004) · Medical Image Analysis · doi:10.1016/j.media.2004.06.025 · Cited by 193 · cited 1×
“The use of deformable models [17] is mainly limited to deformable surfaces [18], with an extension to spatial and time constraints [19].”
MethodSelf-citationThe analysis of cardiac function: A continuum approach
Hunter, P. J., & Smaill, B. H. (1988) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(88)90004-1 · Cited by 191 · cited 2×
“For the electromechanical coupling, different laws have also been proposed [55], [59].”
BackgroundMethodA system for real-time XMR guided cardiovascular intervention
Rhode, K. S., Sermesant, M., Brogan, D., Hegde, S., Hipwell, J., Lambiase, P., Rosenthal, E., Bucknall, C., Qureshi, S. A., Gill, J. S., et al. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856731 · Cited by 168 · cited 1×
“The following references provide examples of the measurement of electrical activity, deformation, flows, fiber orientation [4]–[8], and of the modeling of the electrical and mechanical activity of the heart [9]–[12].”
BackgroundSelf-citationModel-driven brain shift compensation
Skrinjar, O. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00062-2 · Cited by 160 · cited 1×
“IMAGING [16]. The use of deformable models [17] is mainly limited to deformable surfaces [18], with an extension to spatial and time constraints [ 19 ].”
MethodJacob, G., Noble, J. A., Behrenbruch, C., Kelion, A. D., & Banning, A. P. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.996341 · Cited by 142 · cited 1×
“At the same time, deformable templates evolved toward sophisticated approaches, for instance combined with Bayesian classification and Markov random fields [26], or coupling shape-space and Kalman-filter-based tracking [ 27 ].”
MethodCreating a high-resolution spatial/symbolic model of the inner organs based on the Visible Human
Pommert, A., Höhne, Κ. H., Pflesser, B., Richter, E., Riemer, M., Schiemann, T., Schubert, R., Schumacher, U., & Tiede, U. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00044-5 · Cited by 137 · cited 1×
“The quantitative comparison of the behavior of the two models is beyond the scope of this paper, but the multiplication of available DTI data opens up possibilities to precisely analyze the influence and variability in cardiac fiber orientations.”
BackgroundMechanics and material properties of the heart using an anatomically accurate mathematical model.
Nash, M. P. (1998) · ResearchSpace (University of Auckland) · Cited by 136
A Biomechanical Model of Muscle Contraction
Bestel, J., Clément, F., & Sorine, M. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_143 · Cited by 128 · cited 3×
“The electromechanical model proposed here was motivated by the multiscale and phenomenological approach of [62].”
MethodInfluentialEfficient model-based quantification of left ventricular function in 3-D echocardiography
Gérard, O., Billon, A. C., Rouet, J.-M., Jacob, M., Fradkin, M., & Allouche, C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804435 · Cited by 118
Deformable biomechanical models: Application to 4D cardiac image analysis
Maxime Sermesant, B., Forest, C., Pennec, X., Delingette, H., & Ayache, N. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00068-9 · Cited by 112 · cited 2×
“The knowledge of the myocardial fiber orientations (Fig.”
BackgroundSelf-citationAnisotropic filtering for model-based segmentation of 4D cylindrical echocardiographic images
Montagnat, J., Sermesant, M., Delingette, H., Malandain, G., & Ayache, N. (2002) · Pattern Recognition Letters · doi:10.1016/s0167-8655(02)00184-8 · Cited by 91 · cited 1×
“The boundary point is selected among these voxels from intensity, gradient direction and gradient value criteria [74].”
BackgroundSelf-citation[Excitation propagation in nonhomogenous medium (actions analogous to heart fibrillation)].
Krinsky, V. I. (1966) · PubMed · Cited by 90
Faris, O., Evans, F. J., Ennis, D. B., Helm, P. A., Taylor, J. F., Chesnick, A. S., Guttman, M. A., Öztürk, C., & McVeigh, E. R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1560618 · Cited by 84
Mignotte, M., Meunier, J., & Tardif, J. (2001) · Pattern Analysis and Applications · doi:10.1007/pl00010988 · Cited by 84 · cited 1×
“classification and Markov random fields [26], or coupling”
BackgroundMyocardial Fiber Orientation Mapping Using Reduced Encoding Diffusion Tensor Imaging
Hsu, E. W., & Henriquez, C. S. (2001) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-100108588 · Cited by 81 · cited 1×
“Hsu group) [42], with a geometry closest to observed canine anatomies, for instance the right ventricle shape and the septum thickness (see Fig.”
BackgroundNoble, D. (2004) · Physiology · doi:10.1152/physiol.00004.2004 · Cited by 79 · cited 1×
“Many of the functional models of the heart are direct computational models, designed to reproduce in a realistic manner the cardiac activity, often requiring high computational costs and the manual tuning of a very large set of parameters.”
BackgroundMcCulloch, A. D., Bassingthwaighte, J. B., Hunter, P. J., & Noble, D. (1998) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(98)00005-4 · Cited by 60
A FEM-based deformable model for the 3D segmentation and tracking of the heart in cardiac MRI
Pham, Q. C., Vincent, F., Clarysse, P., Croisille, P., & Magnin, I. E. (2002) · International symposium on image and signal processing and analysis/ISPA ... · doi:10.1109/ispa.2001.938636 · Cited by 58
Deformable spatio-temporal shape models: extending active shape models to 2D+time
Hamarneh, G., & Gustavsson, T. (2004) · Image and Vision Computing · doi:10.1016/j.imavis.2003.11.009 · Cited by 53
Segmentation of the left ventricle in cardiac MR images
Jolly, M., Duta, N., & Funka-Lea, G. (2002) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2001.937558 · Cited by 52 · cited 1×
“Volumetric models have mostly been introduced in cardiac function analysis for interpretation [29], [30] as they offer richer mechanical parameters.”
MethodAutomated 3-D echocardiography analysis compared with manual delineations and SPECT MUGA
Sanchez-Ortiz, G. I., Wright, G. A. S., Clarke, N., Declerck, J. M., BANNING, A. P., & Noble, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804434 · Cited by 45 · cited 1×
“Extensions of the PDMs used in segmentation methods are based on the active shape models (ASMs) and the active appearance models (AAM).”
MethodMoreau-Villéger, V., Delingette, H., Maxime Sermesant, B., Ashikaga, H., McVeigh, E. R., & Ayache, N. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.877794 · Cited by 35 · cited 1×
“Also we would like this model to help the interpretation of cardiac image sequences.”
MethodSelf-citationA Physiologically-Based Model for the Active Cardiac Muscle Contraction
Chapelle, D., Clément, F., Génot, F., et al. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45572-8_18 · Cited by 27 · cited 1×
“A detailed study of this complex model and one-dimensional (1-D) simulations can be found in [63] and [64].”
BackgroundDeformable Spatio-Temporal Shape Models:Extending ASM to 2D+Time
Hamarneh, G., & Gustavsson, T. (2001) · British Machine Vision Conference (BMVC) · doi:10.5244/c.15.3 · Cited by 25 · cited 1×
“In [24], the ASM is extended to 2-”
BackgroundDeformable model of the heart with fiber structure
Sitek, A., Klein, G. J., Gullberg, G. T., & Huesman, R. H. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.1039564 · Cited by 20
Cited by
Chabiniok, R., Wang, V. Y., Hadjicharalambous, M., Asner, L., Lee, J., Sermesant, M., Kuhl, E., Young, A. A., Moireau, P., Nash, M. P., et al. (2016) · Interface Focus · doi:10.1098/rsfs.2015.0083 · Cited by 234
“A common approach considers numerical partitioning of the electromechanical system, decoupling the electrical and mechanical problems using implicit–explicit methods [109, 111,113,115,118,119].”
BackgroundSelf-citationSermesant, M., Chabiniok, R., Chinchapatnam, P., Mansi, T., Billet, F., Moireau, P., Peyrat, J. M., Wong, K., Relan, J., Rhode, K., et al. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.07.003 · Cited by 232
Self-citationA guide to modelling cardiac electrical activity in anatomically detailed ventricles
Clayton, R. H., & Panfilov, A. V. (2008) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2007.07.004 · Cited by 220
“This approach is potentially valuable, for example, for patient-specific modelling (Sermesant et al., 2006), which requires multiple adjustments of the models to each specific situation and does not require reproduction of all biophysical details.”
BackgroundModelling passive diastolic mechanics with quantitative MRI of cardiac structure and function
Wang, V. Y., Lam, H. I., Ennis, D. B., Cowan, B. R., Young, A. A., & Nash, M. P. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.006 · Cited by 177
“The use of the affine transformation along with image feature alignments is a common bulk registration method for combining tagged MRI data with DTMRI data (Walker et al., 2004; Sermesant et al., 2006a).”
BackgroundMethodCoupling multi-physics models to cardiac mechanics
Nordsletten, D. A., Niederer, S. A., Nash, M. P., Hunter, P. J., & Smith, N. P. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2009.11.001 · Cited by 176
Metadata
- Authors
- Sermesant, M., Delingette, H., & Ayache, N.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-05
- Volume
- 25
- Issue
- 5
- Pages
- 612-625
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2143941386
- Cited by
- 213
- References
- 50
- FWCI
- 24.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.