The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Segmentation of the Optic Disc, Macula and Vascular Arch in Fundus Photographs
Abstract
An automatic system is presented to find the location of the major anatomical structures in color fundus photographs; the optic disc, the macula, and the vascular arch. These structures are found by fitting a single point-distribution-model to the image, that contains points on each structure. The method can handle optic disc and macula centered images of both the left and the right eye. The system uses a cost function, which is based on a combination of both global and local cues, to find the correct position of the model points. The global terms in the cost function are based on the orientation and width of the vascular pattern in the image. The local term is derived from the image structure around the points of the model. To optimize the fit of the point-distribution-model to an image, a sophisticated combination of optimization processes is proposed which combines optimization in the parameter space of the model and in the image space, where points are moved directly. Experimental results are presented demonstrating that our specific choices for the cost function components and optimization scheme are needed to obtain good results. The system was developed and trained on a set of 500 screening images, and tested on a completely independent set of 500 screening images. In addition to this the system was also tested on a separate set of 100 pathological images. In the screening set it was able to find the vascular arch in 93.2%, the macula in 94.4%, the optic disc location in 98.4% and whether it is dealing with a left or right eye in 100% of all tested cases. For the pathological images test set, this was 77.0%, 92.0%, 94.0%, and 100% respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bellman, R. E. (2010) · doi:10.1515/9781400835386 · Cited by 14,588
Powell, M. J. D. (1964) · The Computer Journal · doi:10.1093/comjnl/7.2.155 · Cited by 4,632 · cited 1×
“techniques were tested, simulated annealing (SA) [16], [17] and Powell’s optimization method [18].”
MethodA Probabilistic Theory of Pattern Recognition
Devroye, L., Györfi, L., & Lugosi, G. (1996) · Stochastic Modelling and Applied Probability · doi:10.1007/978-1-4612-0711-5 · Cited by 3,274
Cited by
Odstrcilik, J., Kolar, R., Budai, A., Hornegger, J., Jan, J., Gazarek, J., Kubena, T., Cernosek, P., Svoboda, O., & Angelopoulou, E. (2013) · IET Image Processing · doi:10.1049/iet-ipr.2012.0455 · Cited by 472
Niemeijer, M., van Ginneken, B., Russell, S. R., Suttorp-Schulten, M. S. A., & Abra`moff, M. D. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0996 · Cited by 400
Self-citationAutomated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Self-citationGeneral Retinal Vessel Segmentation Using Regularization-Based Multiconcavity Modeling
Lam, B. S. Y., Gao, Y., & Liew, A. W.-C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2043259 · Cited by 275
Metadata
- Authors
- Niemeijer, M., Abramoff, M. D., & van Ginneken, B.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2007-01
- Volume
- 26
- Issue
- 1
- Pages
- 116-127
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2167881544
- Cited by
- 220
- References
- 3
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Segmentation of the Optic Disc, Macula and Vascular Arch in Fundus Photographs. https://app.cochat.ai/papers/10.1109/tmi.2006.885336
- The paper
- Niemeijer, M., Abramoff, M. D., & van Ginneken, B. (2007). Segmentation of the Optic Disc, Macula and Vascular Arch in Fundus Photographs. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2006.885336
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.