Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 441

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Optic Disc Detection From Normalized Digital Fundus Images by Means of a Vessels' Direction Matched Filter

Youssif, Aliaa Abdel-Haleim Abdel-Razik, Ghalwash, Atef Zaki, Ghoneim, Amr Ahmed Sabry Abdel-Rahman·2008·IEEE Transactions on Medical Imaging

Abstract

Optic disc (OD) detection is a main step while developing automated screening systems for diabetic retinopathy. We present in this paper a method to automatically detect the position of the OD in digital retinal fundus images. The method starts by normalizing luminosity and contrast through out the image using illumination equalization and adaptive histogram equalization methods respectively. The OD detection algorithm is based on matching the expected directional pattern of the retinal blood vessels. Hence, a simple matched filter is proposed to roughly match the direction of the vessels at the OD vicinity. The retinal vessels are segmented using a simple and standard 2-D Gaussian matched filter. Consequently, a vessels direction map of the segmented retinal vessels is obtained using the same segmentation algorithm. The segmented vessels are then thinned, and filtered using local intensity, to represent finally the OD-center candidates. The difference between the proposed matched filter resized into four different sizes, and the vessels' directions at the surrounding area of each of the OD-center candidates is measured. The minimum difference provides an estimate of the OD-center coordinates. The proposed method was evaluated using a subset of the STARE project's dataset, containing 81 fundus images of both normal and diseased retinas, and initially used by literature OD detection methods. The OD-center was detected correctly in 80 out of the 81 images (98.77%). In addition, the OD-center was detected correctly in all of the 40 images (100%) using the publicly available DRIVE dataset.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2007.900326

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Metadata

Authors
Youssif, A. A.-H. A.-R., Ghalwash, A. Z., & Ghoneim, A. A. S. A.-R.
Venue
IEEE Transactions on Medical Imaging
Published
2008
Volume
27
Issue
1
Pages
11-18
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2086106167
Cited by
441
References
20
FWCI
13.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optic Disc Detection From Normalized Digital Fundus Images by Means of a Vessels' Direction Matched Filter. https://app.cochat.ai/papers/10.1109/tmi.2007.900326
The paper
Youssif, A. A.-H. A.-R., Ghalwash, A. Z., & Ghoneim, A. A. S. A.-R. (2008). Optic Disc Detection From Normalized Digital Fundus Images by Means of a Vessels' Direction Matched Filter. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2007.900326

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.