The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Optic Disc Detection From Normalized Digital Fundus Images by Means of a Vessels' Direction Matched Filter
Abstract
Optic disc (OD) detection is a main step while developing automated screening systems for diabetic retinopathy. We present in this paper a method to automatically detect the position of the OD in digital retinal fundus images. The method starts by normalizing luminosity and contrast through out the image using illumination equalization and adaptive histogram equalization methods respectively. The OD detection algorithm is based on matching the expected directional pattern of the retinal blood vessels. Hence, a simple matched filter is proposed to roughly match the direction of the vessels at the OD vicinity. The retinal vessels are segmented using a simple and standard 2-D Gaussian matched filter. Consequently, a vessels direction map of the segmented retinal vessels is obtained using the same segmentation algorithm. The segmented vessels are then thinned, and filtered using local intensity, to represent finally the OD-center candidates. The difference between the proposed matched filter resized into four different sizes, and the vessels' directions at the surrounding area of each of the OD-center candidates is measured. The minimum difference provides an estimate of the OD-center coordinates. The proposed method was evaluated using a subset of the STARE project's dataset, containing 81 fundus images of both normal and diseased retinas, and initially used by literature OD detection methods. The OD-center was detected correctly in 80 out of the 81 images (98.77%). In addition, the OD-center was detected correctly in all of the 40 images (100%) using the publicly available DRIVE dataset.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Comparative study of retinal vessel segmentation methods on a new publicly available database
Niemeijer, M., Staal, J., van Ginneken, B., Loog, M., & Abramoff, M. D. (2004) · SPIE Proceedings · doi:10.1117/12.535349 · Cited by 790
Locating the optic nerve in a retinal image using the fuzzy convergence of the blood vessels
Hoover, A., & Goldbaum, M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815900 · Cited by 787
Sinthanayothin, C., Boyce, J. F., Cook, H. L., & Williamson, T. H. (1999) · British Journal of Ophthalmology · doi:10.1136/bjo.83.8.902 · Cited by 778
Detection of Optic Disc in Retinal Images by Means of a Geometrical Model of Vessel Structure
Foracchia, M., Grisan, E., & Ruggeri, A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.829331 · Cited by 445
Lalonde, M., Beaulieu, M., & Gagnon, L. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.963823 · Cited by 400
Lowell, J., Hunter, A., Steel, D., Basu, A., Ryder, R., Fletcher, E., & Kennedy, L. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.823261 · Cited by 389
Walter, T., & Klein, J.-C. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45497-7_43 · Cited by 236
Teng, T., Lefley, M., & Claremont, D. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347689 · Cited by 179
Automatic location of optic disk in retinal images
Li, H., & Chutatape, O. (2002) · Proceedings 2001 International Conference on Image Processing (Cat. No.01CH37205) · doi:10.1109/icip.2001.958624 · Cited by 164
Procedure to detect anatomical structures in optical fundus images
Gagnon, L., Lalonde, M., Beaulieu, M., & Boucher, M. C. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.430999 · Cited by 157
Comparison of colour spaces for optic disc localisation in retinal images
Osareh, A., Mirmehdi, M., Thomas, B., & Markham, R. (2003) · doi:10.1109/icpr.2002.1044865 · Cited by 146
A model-based approach for automated feature extraction in fundus images
Li, & Chutatape (2003) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2003.1238371 · Cited by 144
Goldbaum, M. H., Moezzi, S., Taylor, A., Chatterjee, S., Boyd, J., Hunter, E., & Jain, R. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1996.560760 · Cited by 132
Classification and Localisation of Diabetic-Related Eye Disease
Osareh, A., Mirmehdi, M., Thomas, B., & Markham, R. (2002) · Lecture notes in computer science · doi:10.1007/3-540-47979-1_34 · Cited by 130
On the Adaptive Detection of Blood Vessels in Retinal Images
Wu, D. J., Zhang, M., Liu, J.-C., & Bauman, W. C. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862571 · Cited by 116
Abràmoff, M. D., & Niemeijer, M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259622 · Cited by 67
Cited by
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Aquino, A., Gegúndez-Arias, M. E., & Marín, D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053042 · Cited by 516
Computer-aided diagnosis of diabetic retinopathy: A review
Mookiah, M. R. K., Acharya, U. R., Chua, C. K., Lim, C. M., Ng, E. Y. K., & Laude, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.007 · Cited by 430
Glaucoma risk index:Automated glaucoma detection from color fundus images
Bock, R., Meier, J., Nyúl, L. G., Hornegger, J., & Michelson, G. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.006 · Cited by 361
General Retinal Vessel Segmentation Using Regularization-Based Multiconcavity Modeling
Lam, B. S. Y., Gao, Y., & Liew, A. W.-C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2043259 · Cited by 275
Metadata
- Authors
- Youssif, A. A.-H. A.-R., Ghalwash, A. Z., & Ghoneim, A. A. S. A.-R.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008
- Volume
- 27
- Issue
- 1
- Pages
- 11-18
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2086106167
- Cited by
- 441
- References
- 20
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.