Phonovibrography: Mapping High-Speed Movies of Vocal Fold Vibrations Into 2-D Diagrams for Visualizing and Analyzing the Underlying Laryngeal Dynamics
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Endoscopic high-speed laryngoscopy in combination with image analysis strategies is the most promising approach to investigate the interrelation between vocal fold vibrations and voice disorders. So far, due to the lack of an objective and standardized analysis procedure a unique characterization of vocal fold vibrations has not been achieved yet. We present a visualization and analysis strategy which transforms the segmented edges of vibrating vocal folds into a single 2-D image, denoted Phonovibrogram (PVG). Within a PVG the individual type of vocal fold vibration becomes uniquely characterized by specific geometric patterns. The PVG geometries give an intuitive access on the type and degree of the laryngeal asymmetry and can be quantified using an image segmentation approach. The PVG analysis was applied to 14 representative recordings derived from a high-speed database comprising normal and pathological voices. We demonstrate that PVGs are capable to differentiate and quantify different types of normal and pathological vocal fold vibrations. The objective and precise quantification of the PVG geometry may have the potential to realize a novel classification of vocal fold vibrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dejonckere, P. H., Bradley, P., Clemente, P., Cornut, G., Crevier-Buchman, L., Friedrich, G., Van De Heyning, P., Remacle, M., & Woisard, V. (2001) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050000299 · Cited by 1,161 · cited 9×
“The PVGs reveal, that for normal voices the different ELS-categories fade gradually into each other.”
BackgroundInfluentialVideokymography: High-speed line scanning of vocal fold vibration
Švec, J. G., & Schutte, H. K. (1996) · Journal of Voice · doi:10.1016/s0892-1997(96)80047-6 · Cited by 326 · cited 1×
“It inhibits an errant displacement of a trajectory line that frequently occurs in video kymography [30] even if there is a relative shift between the endoscope optic and the larynx during”
BackgroundMeasurement of vocal fold intraglottal pressure and impact stress
Jiang, J. J., & Titze, I. R. (1994) · Journal of Voice · doi:10.1016/s0892-1997(05)80305-4 · Cited by 269 · cited 1×
“At this constriction aerodynamic forces excite vocal fold vibrations [9], [10].”
BackgroundVideostroboscopic evaluation of the larynx.
Bless, D. M., Hirano, M., & Feder, R. J. (1987) · PubMed · Cited by 231
Lohscheller, J., Toy, H., Rosanowski, F., Eysholdt, U., & Döllinger, M. (2007) · Medical Image Analysis · doi:10.1016/j.media.2007.04.005 · Cited by 159 · cited 2×
“In order to obtain a high-quality segmentation, we applied a specially developed image processing algorithm [29].”
MethodSelf-citationNeubauer, J., Mergell, P., Eysholdt, U., & Herzel, H. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1406498 · Cited by 142 · cited 1×
“This approach is a further development of spatio-temporal plots of vocal fold vibrations [27] and of the glottal shape representation proposed by Westphal and Childers [28].”
BackgroundSelf-citationVocal Fold Vibrations: High‐Speed Imaging, Kymography, and Acoustic Analysis: A Preliminary Report
Larsson, H., Hertegård, S., Lindestad, P., & Hammarberg, B. (2000) · The Laryngoscope · doi:10.1097/00005537-200012000-00028 · Cited by 132
An Automatic Method to Quantify the Vibration Properties of Human Vocal Folds via Videokymography
Qiu, Q., Schutte, H. K., Gu, L., & Qi-lian, Y. (2003) · Folia Phoniatrica et Logopaedica · doi:10.1159/000070724 · Cited by 124
Yan, Y., Ahmad, K., Kunduk, M., & Bless, D. M. (2004) · Journal of Voice · doi:10.1016/j.jvoice.2004.04.006 · Cited by 122 · cited 1×
“To analyze the obtained motion data quantitatively, several measures are introduced that describe the symmetry and regularity of vocal fold vibrations [18]–[20].”
MethodIrregular vocal-fold vibration—High-speed observation and modeling
Mergell, P., Herzel, H., & Titze, I. R. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.1314398 · Cited by 122 · cited 1×
“Thus, instabilities of the fundamental frequencies, amplitude and phase asymmetries, and regularity parameters can be computed which describe irregular vocal fold vibrations [21]–[23].”
BackgroundFirst results of clinical application of videokymography
Schutte, H. K., Švec, J. G., & Sram, F. (1998) · The Laryngoscope · doi:10.1097/00005537-199808000-00020 · Cited by 115 · cited 1×
“Thus, several technical solutions have been developed to capture the fast movements of vocal folds [2]–[4].”
BackgroundVocal fold vibration irregularities caused by different types of laryngeal asymmetry
Eysholdt, U., Rosanowski, F., & Hoppe, U. (2003) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-003-0606-y · Cited by 113 · cited 2×
“It allows analysis of all kinds of regular and irregular vibration patterns which are found in normal and pathological voices [7], [8].”
BackgroundSelf-citationVibration parameter extraction from endoscopic image series of the vocal folds
Döllinger, M., Hoppe, U., Hettlich, F., Lohscheller, J., Schuberth, S., & Eysholdt, U. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800755 · Cited by 101 · cited 1×
“The so obtained parameter values are used to classify the degree of the laryngeal asymmetry [24]–[26].”
MethodSelf-citationRecording, processing, and analysis of digital high-speed sequences in glottography
Wittenberg, T. C., Moser, M., Tigges, M., & Eysholdt, U. (1995) · Machine Vision and Applications · doi:10.1007/bf01213501 · Cited by 91 · cited 1×
“To analyze the obtained motion data quantitatively, several measures are introduced that describe the symmetry and regularity of vocal fold vibrations [18]–[20].”
MethodSelf-citationFriedrich, G., & Dejonckere, P. H. O. (2005) · Laryngo-Rhino-Otologie · doi:10.1055/s-2005-861450 · Cited by 80
What have we learned about laryngeal physiology from high-speed digital videoendoscopy?
rd, S. H. (2005) · Current Opinion in Otolaryngology & Head & Neck Surgery · doi:10.1097/01.moo.0000163451.98079.ba · Cited by 75 · cited 1×
“Currently, the most promising approach is endoscopic digital high-speed imaging [5], [6].”
BackgroundComputational Simulations of Vocal Fold Vibration: Bernoulli Versus Navier–Stokes
Decker, G. Z., & Thomson, S. L. (2006) · Journal of Voice · doi:10.1016/j.jvoice.2005.12.002 · Cited by 72 · cited 1×
“At this constriction aerodynamic forces excite vocal fold vibrations [9], [10].”
BackgroundDetecting synchronizations in an asymmetric vocal fold model from time series data
Tokuda, I. T., & Herzel, H. (2005) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.1848232 · Cited by 27 · cited 1×
“Thus, instabilities of the fundamental frequencies, amplitude and phase asymmetries, and regularity parameters can be computed which describe irregular vocal fold vibrations [21]–[23].”
BackgroundHochgeschwindigkeitsglottographische Diagnostik in der Laryngologie
Schade, G., & Müller, F. (2005) · HNO · doi:10.1007/s00106-005-1285-3 · Cited by 19 · cited 1×
“Currently, the most promising approach is endoscopic digital high-speed imaging [ 5 ], [6].”
Background
Cited by
Schlegel, P., Kniesburges, S., Dürr, S., Schützenberger, A., & Döllinger, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-66405-y · Cited by 43
Self-citation
Metadata
- Authors
- Lohscheller, J., Eysholdt, U., Toy, H., & Dollinger, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-03
- Volume
- 27
- Issue
- 3
- Pages
- 300-309
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2153004436
- Cited by
- 164
- References
- 19
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.