The DOI matches its Crossref record.
A Technique for Regional Analysis of Femorotibial Cartilage Thickness Based on Quantitative Magnetic Resonance Imaging
Abstract
The objective of this work was to develop a methodology for measuring cartilage thickness in anatomically based subregions in the tibial and in the central weight-bearing femoral cartilage from magnetic resonance (MR) images. The tibial plateau was divided into a central area of the total subchondral bone area (tAB), and anterior, posterior, internal, and external subregions surrounding it. In the weight-bearing femoral condyles, central, internal, and external subregions were determined. The Euclidean distance between the tAB and cartilage surface was used for determining cartilage thickness. The reproducibility of the method was evaluated on test-retest data sets of 12 participants (six healthy, six with osteoarthritis). The subregion size was varied systematically to study the influence on the reproducibility. The size of the subregions was highly consistent under conditions of repositioning (standard deviation 0.0%-0.3%). The precision errors for regional mean cartilage thickness measurements ranged from 19 microm (1.5%) to 84 microm (4.7%). The computation of regional cartilage thickness values from segmented MR images is shown to be highly reproducible and robust under conditions of joint repositioning. In longitudinal studies, this technique may substantially enhance the ability of quantitative MRI to monitor structural changes in osteoarthritis at narrow time intervals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chehab, E. F., Favre, J., Erhart-Hledik, J. C., & Andriacchi, T. P. (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2014.08.009 · Cited by 353
Hochberg, M. C., Guermazi, A., Guehring, H., Aydemir, A., Wax, S., Fleuranceau-Morel, P., Reinstrup Bihlet, A., Byrjalsen, I., Ragnar Andersen, J., & Eckstein, F. (2019) · JAMA · doi:10.1001/jama.2019.14735 · Cited by 349
Self-citationLohmander, L. S., Hellot, S., Dreher, D., Krantz, E. F. W., Kruger, D. S., Guermazi, A., & Eckstein, F. (2014) · Arthritis & Rheumatology · doi:10.1002/art.38614 · Cited by 275
Self-citationChang, A. H., Moisio, K. C., Chmiel, J. S., Eckstein, F., Guermazi, A., Prasad, P. V., Zhang, Y., Almagor, O., Belisle, L., Hayes, K., et al. (2015) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2015.02.005 · Cited by 274
Self-citationFrobell, R. B., Nevitt, M. C., Hudelmaier, M., Wirth, W., Wyman, B. T., Benichou, O., Dreher, D., Davies, R., Lee, J. H., Baribaud, F., et al. (2010) · Arthritis Care & Research · doi:10.1002/acr.20262 · Cited by 74
Self-citation
Metadata
- Authors
- Wirth, W., & Eckstein, F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-06
- Volume
- 27
- Issue
- 6
- Pages
- 737-744
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2101679106
- Cited by
- 203
- References
- 0
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Technique for Regional Analysis of Femorotibial Cartilage Thickness Based on Quantitative Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1109/tmi.2007.907323
- The paper
- Wirth, W., & Eckstein, F. (2008). A Technique for Regional Analysis of Femorotibial Cartilage Thickness Based on Quantitative Magnetic Resonance Imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2007.907323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.