Tendinopathy Discrimination by Use of Spatial Frequency Parameters in Ultrasound B-Mode Images
The DOI matches its Crossref record.
Abstract
The structural characteristics of a healthy tendon are related to the anisotropic speckle patterns observed in ultrasonic images. This speckle orientation is disrupted upon damage to the tendon structure as observed in patients with tendinopathy. Quantification of the structural appearance of tendon shows promise in creating a tool for diagnosing, prognosing, or measuring changes in tendon organization over time. The current work describes a first step taken towards this goal-classification of Achilles tendon images into tendinopathy and control categories. Eight spatial frequency parameters were extracted from regions of interest on tendon images, filtered and classified using linear discriminant analysis. Resulting algorithms had better than 80% accuracy in categorizing tendon image kernels as tendinopathy or control. Tendon images categorized wrongly provided for an interesting clinical association between incorrect classification of tendinopathy kernels as control and the symptom and clinical time history based inclusion criteria. To assess intersession reliability of image acquisition, the first 10 subjects were imaged twice during separate sessions. Test-retest of repeated measures was excellent (tau = 0.996, ICC = (2, 1) = 0.73 with one outlier) indicating a general consistency in imaging techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tendinopathy: Is Imaging Telling Us the Entire Story?
Docking, S. I., Ooi, C. C., & Connell, D. (2015) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2015.5880 · Cited by 214
Skeletal Muscle Assessment Using Quantitative Ultrasound: A Narrative Review
Ashir, A., Jerban, S., Barrère, V., Wu, Y., Shah, S. B., Andre, M. P., & Chang, E. Y. (2023) · Sensors · doi:10.3390/s23104763 · Cited by 57
Metadata
- Authors
- Bashford, G. R., Tomsen, N., Arya, S., Burnfield, J. M., & Kulig, K.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-05
- Volume
- 27
- Issue
- 5
- Pages
- 608-615
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2112599232
- Cited by
- 88
- References
- 0
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tendinopathy Discrimination by Use of Spatial Frequency Parameters in Ultrasound B-Mode Images. https://app.cochat.ai/papers/10.1109/tmi.2007.912389
- The paper
- Bashford, G. R., Tomsen, N., Arya, S., Burnfield, J. M., & Kulig, K. (2008). Tendinopathy Discrimination by Use of Spatial Frequency Parameters in Ultrasound B-Mode Images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2007.912389
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.