Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Three-Dimensional Cardiac Strain Estimation Using Spatio–Temporal Elastic Registration of Ultrasound Images: A Feasibility Study

Elen, An, Choi, Hon Fai, Loeckx, Dirk, Gao, Hang, Claus, Piet, Suetens, Paul, Maes, Frederik, D'hooge, Jan · 2008 · IEEE Transactions on Medical Imaging

Abstract

Current ultrasound methods for measuring myocardial strain are often limited to measurements in one or two dimensions. Cardiac motion and deformation however are truly 3-D. With the introduction of matrix transducer technology, 3-D ultrasound imaging of the heart has become feasible but suffers from low temporal and spatial resolution, making 3-D strain estimation challenging. In this paper, it is shown that automatic intensity-based spatio-temporal elastic registration of currently available 3-D volumetric ultrasound data sets can be used to measure the full 3-D strain tensor. The method was validated using simulated 3-D ultrasound data sets of the left ventricle (LV). Three types of data sets were simulated: a normal and symmetric LV with different heart rates, a more realistic asymmetric normal LV and an infarcted LV. The absolute error in the estimated displacement was between 0.47 +/-0.23 and 1.00 +/-0.59 mm, depending on heart rate and amount of background noise. The absolute error on the estimated strain was 9%-21% for the radial strain and 1%-4% for the longitudinal and circumferential strains. No large differences were found between the different types of data sets. The shape of the strain curves was estimated properly and the position of the infarcts could be identified correctly. Preliminary results on clinical data taken in vivo from three healthy volunteers and one patient with an apical aneurism confirmed these findings in a qualitative manner as the strain curves obtained with the proposed method have an amplitude and shape similar to what could be expected.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2008.2004420

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 169

Metadata

Authors
Elen, A., Choi, H. F., Loeckx, D., Gao, H., Claus, P., Suetens, P., Maes, F., & D'hooge, J.
Venue
IEEE Transactions on Medical Imaging
Published
2008-11
Volume
27
Issue
11
Pages
1580-1591
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2117333116
Cited by
169
References
2
FWCI
10.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-Dimensional Cardiac Strain Estimation Using Spatio–Temporal Elastic Registration of Ultrasound Images: A Feasibility Study. https://app.cochat.ai/papers/10.1109/tmi.2008.2004420
The paper
Elen, A., Choi, H. F., Loeckx, D., Gao, H., Claus, P., Suetens, P., Maes, F., & D'hooge, J. (2008). Three-Dimensional Cardiac Strain Estimation Using Spatio–Temporal Elastic Registration of Ultrasound Images: A Feasibility Study. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2008.2004420

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.