The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tractography Gone Wild: Probabilistic Fibre Tracking Using the Wild Bootstrap With Diffusion Tensor MRI
Abstract
Diffusion tensor magnetic resonance imaging (DT-MRI) permits the noninvasive assessment of tissue microstructure and, with fibre-tracking algorithms, allows for the 3-D trajectories of white matter fasciculi to be reconstructed noninvasively. Probabilistic algorithms allow one to assign a "confidence" to a given reconstructed pathway--but often rely on a priori assumptions about sources of uncertainty in the data. Bootstrap methods have been proposed as a way of circumventing this problem, deriving the uncertainty from the data themselves--but acquisition times for data amenable to precise and robust bootstrapping are clinically prohibitive. By combining the wild bootstrap, recently introduced to the DT-MRI literature, with tractography, we show how confidence can be assigned to reconstructed trajectories using data collected in a fraction of the time required for regular bootstrapping. We compare in vivo wild bootstrap tracking results with regular tracking results and show that results are comparable. This approach therefore allows users who have collected data sets for use with deterministic tracking algorithms, rather than those specifically designed for bootstrapping, to be able to apply bootstrap analyses and retrospectively assign confidence to their reconstructed trajectories with minimum additional effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive mapping of connections between human thalamus and cortex using diffusion imaging
Behrens, T. E. J., Johansen-Berg, H., Woolrich, M. W., Smith, S. M., Wheeler-Kingshott, C. A. M., Boulby, P. A., Barker, G. J., Sillery, E. L., Sheehan, K., Ciccarelli, O., et al. (2003) · Nature Neuroscience · doi:10.1038/nn1075 · Cited by 2,330
Cited by
MRtrix3: A fast, flexible and open software framework for medical image processing and visualisation
Tournier, J.-D., Smith, R., Raffelt, D., Tabbara, R., Dhollander, T., Pietsch, M., Christiaens, D., Jeurissen, B., Yeh, C.-H., & Connelly, A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116137 · Cited by 2,974
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Self-citationSmith, R. E., Tournier, J.-D., Calamante, F., & Connelly, A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.005 · Cited by 1,216
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Challenges and limitations of quantifying brain connectivity in vivo with diffusion MRI
Jones, D. K. (2010) · Imaging in Medicine · doi:10.2217/iim.10.21 · Cited by 321
Self-citation
Metadata
- Authors
- Jones, D. K.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-09
- Volume
- 27
- Issue
- 9
- Pages
- 1268-1274
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2146264551
- Cited by
- 161
- References
- 1
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tractography Gone Wild: Probabilistic Fibre Tracking Using the Wild Bootstrap With Diffusion Tensor MRI. https://app.cochat.ai/papers/10.1109/tmi.2008.922191
- The paper
- Jones, D. K. (2008). Tractography Gone Wild: Probabilistic Fibre Tracking Using the Wild Bootstrap With Diffusion Tensor MRI. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2008.922191
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.