The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Convergence and Parameter Choice for Monte-Carlo Simulations of Diffusion MRI
Abstract
This paper describes a general and flexible Monte- Carlo simulation framework for diffusing spins that generates realistic synthetic data for diffusion magnetic resonance imaging. Similar systems in the literature consider only simple substrates and their authors do not consider convergence and parameter optimization. We show how to run Monte-Carlo simulations within complex irregular substrates. We compare the results of the Monte-Carlo simulation to an analytical model of restricted diffusion to assess precision and accuracy of the generated results. We obtain an optimal combination of spins and updates for a given run time by trading off number of updates in favor of number of spins such that precision and accuracy of sythesized data are both optimized. Further experiments demonstrate the system using a tissue environment that current analytic models cannot capture. This tissue model incorporates swelling, abutting, and deformation. Swelling-induced restriction in the extracellular space due to the effects of abutting cylinders leads to large departures from the predictions of the analytical model, which does not capture these effects. This swelling-induced restriction may be an important mechanism in explaining the changes in apparent diffusion constant observed in the aftermath of acute ischemic stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
Direct and fast detection of neuronal activation in the human brain with diffusion MRI
Le Bihan, D., Urayama, S.-I., Aso, T., Hanakawa, T., & Fukuyama, H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600644103 · Cited by 272
Cited by
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
Self-citationAccelerated microstructure imaging via Convex Optimization (AMICO) from diffusion MRI data
Daducci, A., Canales-Rodríguez, E. J., Zhang, H., Dyrby, T. B., Alexander, D. C., & Thiran, J.-P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.026 · Cited by 593
Self-citationQuantitative evaluation of 10 tractography algorithms on a realistic diffusion MR phantom
Fillard, P., Descoteaux, M., Goh, A., Gouttard, S., Jeurissen, B., Malcolm, J., Ramirez-Manzanares, A., Reisert, M., Sakaie, K., Tensaouti, F., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.032 · Cited by 418
SANDI: a compartment‐based model for non‐invasive apparent soma and neurite imaging by diffusion MRI
Palombo, M., Ianus, A., Guerreri, M., Nunes, D., Alexander, D. C., Shemesh, N., & Zhang, H. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116835 · Cited by 349
Self-citationDesign and Validation of Diffusion MRI Models of White Matter
Jelescu, I. O., & Budde, M. D. (2017) · Frontiers in Physics · doi:10.3389/fphy.2017.00061 · Cited by 240
Metadata
- Authors
- Hall, M. G., & Alexander, D. C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2009-09
- Volume
- 28
- Issue
- 9
- Pages
- 1354-1364
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2102520467
- Cited by
- 215
- References
- 3
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Convergence and Parameter Choice for Monte-Carlo Simulations of Diffusion MRI. https://app.cochat.ai/papers/10.1109/tmi.2009.2015756
- The paper
- Hall, M. G., & Alexander, D. C. (2009). Convergence and Parameter Choice for Monte-Carlo Simulations of Diffusion MRI. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2009.2015756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.