Quantitative Comparison of Spot Detection Methods in Fluorescence Microscopy
The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
Quantitative analysis of biological image data generally involves the detection of many subresolution spots. Especially in live cell imaging, for which fluorescence microscopy is often used, the signal-to-noise ratio (SNR) can be extremely low, making automated spot detection a very challenging task. In the past, many methods have been proposed to perform this task, but a thorough quantitative evaluation and comparison of these methods is lacking in the literature. In this paper, we evaluate the performance of the most frequently used detection methods for this purpose. These include seven unsupervised and two supervised methods. We perform experiments on synthetic images of three different types, for which the ground truth was available, as well as on real image data sets acquired for two different biological studies, for which we obtained expert manual annotations to compare with. The results from both types of experiments suggest that for very low SNRs ( approximately 2), the supervised (machine learning) methods perform best overall. Of the unsupervised methods, the detectors based on the so-called h -dome transform from mathematical morphology or the multiscale variance-stabilizing transform perform comparably, and have the advantage that they do not require a cumbersome learning stage. At high SNRs ( > 5), the difference in performance of all considered detectors becomes negligible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid object detection using a boosted cascade of simple features
Viola, P., & Jones, M. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990517 · Cited by 18,300
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Abràmoff, M. D., Magalhães, P. J., & Ram, S. J. (2004) · Utrecht University Repository (Utrecht University) · Cited by 15,417
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
A tutorial on particle filters for online nonlinear/non-Gaussian Bayesian tracking
Arulampalam, M. S., Maskell, S., Gordon, N., & Clapp, T. (2002) · IEEE Transactions on Signal Processing · doi:10.1109/78.978374 · Cited by 11,502
Mean shift: a robust approach toward feature space analysis
Comaniciu, D., & Meer, P. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.1000236 · Cited by 11,305
Bilateral Filtering for Gray and Color Images
Tomasi, C., & Manduchi, R. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710815 · Cited by 8,177 · cited 1×
“3) Patch-Based Denoising: Noise can also be reduced to some extent while preserving object appearance by using median filtering [39], maximum homogeneity neighbor (MHN) filtering [46], bilateral filtering [47], mean-shift filtering [48], and anisotropic diffusion [49].”
BackgroundImage analysis and mathematical morphology
(1982) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(82)90078-8 · Cited by 8,151
(1986) · Cited by 3,616
Morphological Image Analysis: Principles and Applications
(2000) · Sensor Review · doi:10.1108/sr.2000.08720cae.001 · Cited by 3,537
Cited by
Methods for Cell and Particle Tracking
Meijering, E., Dzyubachyk, O., & Smal, I. (2012) · Methods in Enzymology · doi:10.1016/b978-0-12-391857-4.00009-4 · Cited by 1,400
Self-citationObjective comparison of particle tracking methods
Chenouard, N., Smal, I., de Chaumont, F., Maška, M., Sbalzarini, I. F., Gong, Y., Cardinale, J., Carthel, C., Coraluppi, S., Winter, M., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2808 · Cited by 894
Self-citationSingle Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Stem cell migration and mechanotransduction on linear stiffness gradient hydrogels
Hadden, W. J., Young, J. L., Holle, A. W., McFetridge, M. L., Kim, D. Y., Wijesinghe, P., Taylor-Weiner, H., Wen, J. H., Lee, A. R., Bieback, K., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1618239114 · Cited by 479
Multiple Hypothesis Tracking for Cluttered Biological Image Sequences
Chenouard, N., Bloch, I., & Olivo-Marin, J. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2013.97 · Cited by 232
Newby, J. M., Schaefer, A. M., Lee, P. T., Forest, M. G., & Lai, S. K. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1804420115 · Cited by 195
A bird's-eye view of deep learning in bioimage analysis
Meijering, E. (2020) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2020.08.003 · Cited by 126
Self-citationAutomatic detection of impact damage in carbon fiber composites using active thermography
Usamentiaga, R., Venegas, P., Guerediaga, J., Vega, L., & López, I. (2013) · Infrared Physics & Technology · doi:10.1016/j.infrared.2013.01.004 · Cited by 67
Metadata
- Authors
- Smal, I., Loog, M., Niessen, W., & Meijering, E.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-02
- Volume
- 29
- Issue
- 2
- Pages
- 282-301
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2168237413
- Cited by
- 255
- References
- 72
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.