Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record.

Simultaneous Reconstruction of Activity and Attenuation for PET/MR

Salomon, André, Goedicke, Andreas, Schweizer, Bernd, Aach, Til, Schulz, Volkmar · 2011 · IEEE Transactions on Medical Imaging

Abstract

Medical investigations targeting a quantitative analysis of the position emission tomography (PET) images require the incorporation of additional knowledge about the photon attenuation distribution in the patient. Today, energy range adapted attenuation maps derived from computer tomography (CT) scans are used to effectively compensate for image quality degrading effects, such as attenuation and scatter. Replacing CT by magnetic resonance (MR) is considered as the next evolutionary step in the field of hybrid imaging systems. However, unlike CT, MR does not measure the photon attenuation and thus does not provide an easy access to this valuable information. Hence, many research groups currently investigate different technologies for MR-based attenuation correction (MR-AC). Typically, these approaches are based on techniques such as special acquisition sequences (alone or in combination with subsequent image processing), anatomical atlas registration, or pattern recognition techniques using a data base of MR and corresponding CT images. We propose a generic iterative reconstruction approach to simultaneously estimate the local tracer concentration and the attenuation distribution using the segmented MR image as anatomical reference. Instead of applying predefined attenuation values to specific anatomical regions or tissue types, the gamma attenuation at 511 keV is determined from the PET emission data. In particular, our approach uses a maximum-likelihood estimation for the activity and a gradient-ascent based algorithm for the attenuation distribution. The adverse effects of scattered and accidental gamma coincidences on the quantitative accuracy of PET, as well as artifacts caused by the inherent crosstalk between activity and attenuation estimation are efficiently reduced using enhanced decay event localization provided by time-of-flight PET, accurate correction for accidental coincidences, and a reduced number of unknown attenuation coefficients. First results achieved with measured whole body PET data and reference segmentation from CT showed an absolute mean difference of 0.005 cm⁻¹ (< 20%) in the lungs, 0.0009 cm⁻¹ (< 2%) in case of fat, and 0.0015 cm⁻¹ (< 2%) for muscles and blood. The proposed method indicates a robust and reliable alternative to other MR-AC approaches targeting patient specific quantitative analysis in time-of-flight PET/MR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2010.2095464

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Salomon, A., Goedicke, A., Schweizer, B., Aach, T., & Schulz, V.
Venue
IEEE Transactions on Medical Imaging
Published
2011-03
Volume
30
Issue
3
Pages
804-813
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2150822300
Cited by
174
References
0
FWCI
10.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous Reconstruction of Activity and Attenuation for PET/MR. https://app.cochat.ai/papers/10.1109/tmi.2010.2095464
The paper
Salomon, A., Goedicke, A., Schweizer, B., Aach, T., & Schulz, V. (2011). Simultaneous Reconstruction of Activity and Attenuation for PET/MR. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2010.2095464

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.