The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Optic Disk and Cup Segmentation From Monocular Color Retinal Images for Glaucoma Assessment
Abstract
Automatic retinal image analysis is emerging as an important screening tool for early detection of eye diseases. Glaucoma is one of the most common causes of blindness. The manual examination of optic disk (OD) is a standard procedure used for detecting glaucoma. In this paper, we present an automatic OD parameterization technique based on segmented OD and cup regions obtained from monocular retinal images. A novel OD segmentation method is proposed which integrates the local image information around each point of interest in multidimensional feature space to provide robustness against variations found in and around the OD region. We also propose a novel cup segmentation method which is based on anatomical evidence such as vessel bends at the cup boundary, considered relevant by glaucoma experts. Bends in a vessel are robustly detected using a region of support concept, which automatically selects the right scale for analysis. A multi-stage strategy is employed to derive a reliable subset of vessel bends called r-bends followed by a local spline fitting to derive the desired cup boundary. The method has been evaluated on 138 images comprising 33 normal and 105 glaucomatous images against three glaucoma experts. The obtained segmentation results show consistency in handling various geometric and photometric variations found across the dataset. The estimation error of the method for vertical cup-to-disk diameter ratio is 0.09/0.08 (mean/standard deviation) while for cup-to-disk area ratio it is 0.12/0.10. Overall, the obtained qualitative and quantitative results show effectiveness in both segmentation and subsequent OD parameterization for glaucoma assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
Use of the hough transformation to detect lines and curves in pictures
Duda, R. O., & Hart, P. E. (1972) · Communications of the ACM · doi:10.1145/361237.361242 · Cited by 6,633
Optimal approximations by piecewise smooth functions and associated variational problems
Mumford, D., & Shah, J. (1989) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160420503 · Cited by 5,208
Localizing Region-Based Active Contours
Lankton, S., & Tannenbaum, A. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2004611 · Cited by 1,137
Retinal Blood Vessel Segmentation Using Line Operators and Support Vector Classification
Ricci, E., & Perfetti, R. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.898551 · Cited by 818
Active Contours without Edges for Vector-Valued Images
Chan, T. F., Sandberg, B. Y., & Vese, L. A. (2000) · Journal of Visual Communication and Image Representation · doi:10.1006/jvci.1999.0442 · Cited by 687
Retinal image analysis: Concepts, applications and potential
Patton, N., Aslam, T. M., MacGillivray, T., Deary, I. J., Dhillon, B., Eikelboom, R. H., Yogesan, K., & Constable, I. J. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2005.07.001 · Cited by 641
Automated Feature Extraction in Color Retinal Images by a Model Based Approach
Li, H., & Chutatape, O. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820400 · Cited by 545
Active contours driven by local Gaussian distribution fitting energy
Wang, L., He, L., Mishra, A., & Li, C. (2009) · Signal Processing · doi:10.1016/j.sigpro.2009.03.014 · Cited by 466
Lalonde, M., Beaulieu, M., & Gagnon, L. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.963823 · Cited by 400
Lowell, J., Hunter, A., Steel, D., Basu, A., Ryder, R., Fletcher, E., & Kennedy, L. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.823261 · Cited by 389
Constructing models for content-based image retrieval
Schmid, C. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990922 · Cited by 367
Glaucoma risk index:Automated glaucoma detection from color fundus images
Bock, R., Meier, J., Nyúl, L. G., Hornegger, J., & Michelson, G. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.006 · Cited by 361
Screening for Diabetic Retinopathy
Singer, D. E., Nathan, D. M., Fogel, H. A., & Schachat, A. P. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-116-8-660 · Cited by 292
Abra`moff, M. D., Alward, W. L. M., Greenlee, E. C., Shuba, L., Kim, C. Y., Fingert, J. H., & Kwon, Y. H. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-1081 · Cited by 236
Integrated active contours for texture segmentation
Sagiv, C., Sochen, N. A., & Zeevi, Y. Y. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.871133 · Cited by 214
Curvature scale space corner detector with adaptive threshold and dynamic region of support
He, X., & Yung, N. H. C. (2004) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2004.1334377 · Cited by 187
Optic disk feature extraction via modified deformable model technique for glaucoma analysis
Xu, J., Chutatape., O., Sung, E., Zheng, C., & Kuan, P. C. T. (2007) · Pattern Recognition · doi:10.1016/j.patcog.2006.10.015 · Cited by 185
Level-set based automatic cup-to-disc ratio determination using retinal fundus images in ARGALI
Wong, D. W. K., Liu, J., Lim, J. H., Jia, X., Yin, F., Li, H., & Wong, T. Y. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649648 · Cited by 171
A model-based approach for automated feature extraction in fundus images
Li, & Chutatape (2003) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2003.1238371 · Cited by 144
Identification of the optic disk boundary in retinal images using active contours
Mendels, F., Heneghan, C., & Thiran, J. (1999) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 140
Classifying Glaucoma with Image-Based Features from Fundus Photographs
Bock, R., Meier, J., Michelson, G., Nyúl, L. G., & Joachim Hornegger, A. (2007) · Springer eBooks · doi:10.1007/978-3-540-74936-3_36 · Cited by 105
Boundary detection of optic disk by a modified ASM method
Li, H., & Chutatape., O. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(03)00052-9 · Cited by 98
Automated detection of kinks from blood vessels for optic cup segmentation in retinal images
Wong, D. W. K., Liu, J., Lim, J., Li, H., & Wong, T. Y. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.810784 · Cited by 77
Unsupervised curvature-based retinal vessel segmentation
Garg, S., Sivaswamy, J., & Chandra, S. (2007) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2007.356859 · Cited by 69
Self-citationEffects of Preprocessing Eye Fundus Images on Appearance Based Glaucoma Classification
Meier, J., Bock, R., Michelson, G., et al. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-74272-2_21 · Cited by 55
Automated Optic Disc Localization and Contour Detection Using Ellipse Fitting and Wavelet Transform
Pallawala, P. M. D. S., Hsu, W., Lee, M. L., & Eong, K. A. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-24671-8_11 · Cited by 51
Colour Morphology and Snakes for Optic Disc Localisation
Osareh, A., Mirmehdi, M., Thomas, B., & Markham, R. H. (2002) · Bristol Research (University of Bristol) · Cited by 46
Localisation of the optic disc by means of GA-optimised Topological Active Nets
Novo, J., Penedo, M. G., & Santos, J. C. A. (2009) · Image and Vision Computing · doi:10.1016/j.imavis.2009.02.011 · Cited by 29
Cited by
Orlando, J. I., Fu, H., Barbosa Breda, J., van Keer, K., Bathula, D. R., Diaz-Pinto, A., Fang, R., Heng, P.-A., Kim, J., Lee, J., et al. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101570 · Cited by 855
Joint Optic Disc and Cup Segmentation Based on Multi-Label Deep Network and Polar Transformation
Fu, H., Cheng, J., Xu, Y., Wong, D. W. K., Liu, J., & Cao, X. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2791488 · Cited by 834
Superpixel Classification Based Optic Disc and Optic Cup Segmentation for Glaucoma Screening
Cheng, J., Liu, J., Xu, Y., Yin, F., Wong, D. W. K., Tan, N.-M., Tao, D., Cheng, C.-Y., Aung, T., & Wong, T. Y. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2247770 · Cited by 593
Drishti-GS: Retinal image dataset for optic nerve head(ONH) segmentation
Sivaswamy, J., Krishnadas, S. R., Datt Joshi, G., Jain, M., & Syed Tabish, A. U. (2014) · 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2014.6867807 · Cited by 540
Self-citationAquino, A., Gegúndez-Arias, M. E., & Marín, D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053042 · Cited by 516
Metadata
- Authors
- Joshi, G. D., Sivaswamy, J., & Krishnadas, S. R.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-06
- Volume
- 30
- Issue
- 6
- Pages
- 1192-1205
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2108824200
- Cited by
- 412
- References
- 29
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.