Image-Based Model of Atrial Anatomy and Electrical Activation: A Computational Platform for Investigating Atrial Arrhythmia
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Computer models provide a powerful platform for investigating mechanisms that underlie atrial rhythm disturbances. We have used novel techniques to build a structurally-detailed, image-based model of 3-D atrial anatomy. A volume image of the atria from a normal sheep heart was acquired using serial surface macroscopy, then smoothed and down-sampled to 50 μm(3) resolution. Atrial surface geometry was identified and myofiber orientations were estimated throughout by eigen-analysis of the 3-D image structure tensor. Sinus node, crista terminalis, pectinate muscle, Bachman's bundle, and pulmonary veins were segmented on the basis of anatomic characteristics. Heterogeneous electrical properties were assigned to this structure and electrical activation was simulated on it at 100 μm(3) resolution, using both biophysically-detailed and reduced-order cell activation models with spatially-varying membrane kinetics. We confirmed that the model reproduced key features of the normal spread of atrial activation. Furthermore, we demonstrate that vulnerability to rhythm disturbance caused by structural heterogeneity in the posterior left atrium is exacerbated by spatial variation of repolarization kinetics across this region. These results provide insight into mechanisms that may sustain paroxysmal atrial fibrillation. We conclude that image-based computer models that incorporate realistic descriptions of atrial myofiber architecture and electrophysiologic properties have the potential to analyse and identify complex substrates for atrial fibrillation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273 · cited 9×
“Experimental sheep models are increasingly being used to study PtAF [44] and if structure-based computer models are to be used to interpret these data, it will be necessary to acquire representative volumetric models of sheep atria from such animals.”
BackgroundResultInfluential
Cited by
Calcium in the Pathophysiology of Atrial Fibrillation and Heart Failure
Denham, N. C., Pearman, C. M., Caldwell, J. L., Madders, G. W. P., Eisner, D. A., Trafford, A. W., & Dibb, K. M. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01380 · Cited by 175
Three-dimensional cardiac computational modelling: methods, features and applications.
Lopez-Perez, A., Sebastian, R., & Ferrero, J. M. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0033-5 · Cited by 151
“Fibre orientation can also be obtained from measurements taken on explanted hearts [12,35], by analysing histological sections under microscope [11] or by digital processing (structure tensor method) of volume images assembled from high-resolution pictures of very thin histological slices [25,44].”
BackgroundValidation and Trustworthiness of Multiscale Models of Cardiac Electrophysiology
Pathmanathan, P., & Gray, R. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00106 · Cited by 63
“, 2004), 3D slab of tissue, the atria (Seemann et al., 2006; Zhao et al., 2013), the ventricles (Plank et al.”
BackgroundNguyen, T. D., Kadri, O. E., & Voronov, R. S. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.529365 · Cited by 19
“…be enhanced using digital post-processing, such as deconvolution (i.e., minimizing noise caused by objects outside of the imaging plane) and structure tensor analysis (e.g., enhancing visibility of the structural features for the fiber orientation detection) (Burton et al., 2006; Zhao et al., 2013).”
Metadata
- Authors
- Zhao, J., Butters, T. D., Zhang, H., LeGrice, I. J., Sands, G. B., & Smaill, B. H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-01
- Volume
- 32
- Issue
- 1
- Pages
- 18-27
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2029115054
- Cited by
- 44
- References
- 1
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image-Based Model of Atrial Anatomy and Electrical Activation: A Computational Platform for Investigating Atrial Arrhythmia. https://app.cochat.ai/papers/10.1109/tmi.2012.2227776
- The paper
- Zhao, J., Butters, T. D., Zhang, H., LeGrice, I. J., Sands, G. B., & Smaill, B. H. (2013). Image-Based Model of Atrial Anatomy and Electrical Activation: A Computational Platform for Investigating Atrial Arrhythmia. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2012.2227776
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.