CoChat

Automatic Detection of Optic Disc Based on PCA and Mathematical Morphology

Open access
Morales, Sandra, Naranjo, Valery, Angulo, Jesús, Alcañiz, Mariano · 2013 · IEEE Transactions on Medical Imaging
Cited by 221

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The algorithm proposed in this paper allows to automatically segment the optic disc from a fundus image. The goal is to facilitate the early detection of certain pathologies and to fully automate the process so as to avoid specialist intervention. The method proposed for the extraction of the optic disc contour is mainly based on mathematical morphology along with principal component analysis (PCA). It makes use of different operations such as generalized distance function (GDF), a variant of the watershed transformation, the stochastic watershed, and geodesic transformations. The input of the segmentation method is obtained through PCA. The purpose of using PCA is to achieve the grey-scale image that better represents the original RGB image. The implemented algorithm has been validated on five public databases obtaining promising results. The average values obtained (a Jaccard's and Dice's coefficients of 0.8200 and 0.8932, respectively, an accuracy of 0.9947, and a true positive and false positive fractions of 0.9275 and 0.0036) demonstrate that this method is a robust tool for the automatic segmentation of the optic disc. Moreover, it is fairly reliable since it works properly on databases with a large degree of variability and improves the results of other state-of-the-art methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2013.2238244

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Ridge-based vessel segmentation in color images of the retina

    Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202 · cited 7×

    “TABLE III COMPARISON OF THE PROPOSED METHOD WITH THE WORK PRESENTED IN [20] IN BASED ON JACCARD’S COEFFICIENT (JC) AND MAD ON DIARETDB1 AND DRIVE DATABASES TABLE IV SUBJECTIVE CLASSIFICATION OF PERFORMANCE ON ONHSD DATASET Referring to the databases employed, most of the images included in them are pathological and th…”
    MethodInfluential
  • Principal Component Analysis

    (2002) · Springer Series in Statistics · doi:10.1007/b98835 · Cited by 919

Show all 2 references

Cited by

See all 221

Metadata

Authors
Morales, S., Naranjo, V., Angulo, J., & Alcañiz, M.
Venue
IEEE Transactions on Medical Imaging
Published
2013-04
Volume
32
Issue
4
Pages
786-796
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W1992086640
Cited by
221
References
2
FWCI
12.83
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic Detection of Optic Disc Based on PCA and Mathematical Morphology. https://app.cochat.ai/papers/10.1109/tmi.2013.2238244
The paper
Morales, S., Naranjo, V., Angulo, J., & Alcañiz, M. (2013). Automatic Detection of Optic Disc Based on PCA and Mathematical Morphology. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2013.2238244

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.