The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity
Open accessAbstract
Ultrafast ultrasonic imaging is a rapidly developing field based on the unfocused transmission of plane or diverging ultrasound waves. This recent approach to ultrasound imaging leads to a large increase in raw ultrasound data available per acquisition. Bigger synchronous ultrasound imaging datasets can be exploited in order to strongly improve the discrimination between tissue and blood motion in the field of Doppler imaging. Here we propose a spatiotemporal singular value decomposition clutter rejection of ultrasonic data acquired at ultrafast frame rate. The singular value decomposition (SVD) takes benefits of the different features of tissue and blood motion in terms of spatiotemporal coherence and strongly outperforms conventional clutter rejection filters based on high pass temporal filtering. Whereas classical clutter filters operate on the temporal dimension only, SVD clutter filtering provides up to a four-dimensional approach (3D in space and 1D in time). We demonstrate the performance of SVD clutter filtering with a flow phantom study that showed an increased performance compared to other classical filters (better contrast to noise ratio with tissue motion between 1 and 10mm/s and axial blood flow as low as 2.6 mm/s). SVD clutter filtering revealed previously undetected blood flows such as microvascular networks or blood flows corrupted by significant tissue or probe motion artifacts. We report in vivo applications including small animal fUltrasound brain imaging (blood flow detection limit of 0.5 mm/s) and several clinical imaging cases, such as neonate brain imaging, liver or kidney Doppler imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“removing the N = 60 first components of the singular value decomposition, which optimally exploited the spatiotemporal dynamics of the full Doppler film for clutter rejection, largely outperforming conventional clutter-rejection filters used in Doppler ultrasound47.”
From Local hippocampal fast gamma rhythms precede brain-wide hyperemic patterns during spontaneous rodent REM sleep (2018) · cites this paper as [47]
Citations
Cites
Robust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. N. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 7,048
The approximation of one matrix by another of lower rank
Eckart, C., & Young, G. (1936) · Psychometrika · doi:10.1007/bf02288367 · Cited by 4,497
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,496
Self-citationCoherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,824
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,157
Self-citationFunctional ultrasound imaging of the brain
Macé, É., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 806
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.6689779 · Cited by 697
Self-citationOtazo, R., Candès, E. J., & Sodickson, D. K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 667
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savéry, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 514
Self-citationROBUST PRINCIPAL COMPONENT ANALYSIS
Alanzi, A. R. A. (2014) · OpenSIUC (Southern Illinois University Carbondale) · Cited by 419
Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Tanter, M., Bercoff, J., Sandrin, L., & Fink, M. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041078 · Cited by 415
Self-citationSPATIOTEMPORAL IMAGINGWITH PARTIALLY SEPARABLE FUNCTIONS
Liang, Z. (2007) · IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI) · doi:10.1109/isbi.2007.357020 · Cited by 379
3D ultrafast ultrasound imaging in vivo
Provost, J., Papadacci, C., Arango, J. E., Imbault, M., Fink, M., Gennisson, J., Tanter, M., & Pernot, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/19/l1 · Cited by 370
Self-citationFunctional ultrasound imaging of the brain: theory and basic principles
Macé, É., Montaldo, G., Osmanski, B.-F., Cohen, I., Fink, M., & Tanter, M. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2592 · Cited by 356
Self-citationMulti-energy CT based on a prior rank, intensity and sparsity model (PRISM)
Gao, H., Yu, H., Osher, S., & Wang, G. (2011) · Inverse Problems · doi:10.1088/0266-5611/27/11/115012 · Cited by 267
Clutter filter design for ultrasound color flow imaging
Bjærum, S., Torp, H., & Kristoffersen, K. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.985705 · Cited by 258
Unbiased Risk Estimates for Singular Value Thresholding and Spectral Estimators
Candès, E. J., Sing‐Long, C., & Trzasko, J. D. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2270464 · Cited by 251
Blood flow velocity in capillaries of brain and muscles and its physiological significance
Иванов, К. П., Kalinina, M. K., & Levkovich, Y. I. (1981) · Microvascular Research · doi:10.1016/0026-2862(81)90084-4 · Cited by 214
Eigen-based clutter filter design for ultrasound color flow imaging: a review
Yu, A. C. H., & Løvstakken, L. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1521 · Cited by 208
Spatiotemporal Imaging with Partially Separable Functions
Liang, Z. (2007) · doi:10.1109/nfsi-icfbi.2007.4387720 · Cited by 205
Osmanski, B.-F., Pezet, S., Ricobaraza, A., Lenkei, Z., & Tanter, M. (2014) · Nature Communications · doi:10.1038/ncomms6023 · Cited by 197
Self-citationMinimax risk of matrix denoising by singular value thresholding
Donoho, D. L., & Gavish, M. (2014) · The Annals of Statistics · doi:10.1214/14-aos1257 · Cited by 127
Clutter filters adapted to tissue motion in ultrasound color flow imaging
Bjærum, S., Torp, H. G., & Kristoffersen, K. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1009328 · Cited by 123
Ledoux, L. A. F., Brands, P. J., & Hoeks, A. P. G. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900101 · Cited by 121
Kadi, A. P., & Loupas, T. (1995) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.464825 · Cited by 110
Ultrafast Doppler Reveals the Mapping of Cerebral Vascular Resistivity in Neonates
Demené, C., Pernot, M., Biran, V., Alison, M., Fink, M., Baud, O., & Tanter, M. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.49 · Cited by 109
Self-citationKruse, D. E., & Ferrara, K. W. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041080 · Cited by 97
Ultrafast Doppler Imaging of Blood Flow Dynamics in the Myocardium
Osmanski, B.-F., Pernot, M., Montaldo, G., Bel, A., Messas, E., & Tanter, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203316 · Cited by 95
Self-citationAn Efficient Algorithm to Remove Low Frequency Doppler Signals in Digital Doppler Systems
Hoeks, A. P. G., van de Vorst, J., Dabekaussen, A., Brands, P. J., & Reneman, R. S. (1991) · Ultrasonic Imaging · doi:10.1177/016173469101300202 · Cited by 86
Robust Principal Component Analysis
Vidal, R., Ma, Y., & Sastry, S. S. (2016) · Interdisciplinary applied mathematics · doi:10.1007/978-0-387-87811-9_3 · Cited by 82
The variance of quantitative estimates in shear wave imaging: Theory and experiments
Deffieux, T., Gennisson, J., Larrat, B., Fink, M., & Tanter, M. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2472 · Cited by 80
Self-citationOsmanski, B.-F., Martin, C., Montaldo, G., Lanièce, P., Pain, F., Tanter, M., & Gurden, H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.054 · Cited by 74
Self-citationReal-time adaptive clutter rejection filtering in color flow imaging using power method iterations
Løvstakken, L., Bjærum, S., Kristoffersen, K., Haaverstad, R., & Torp, H. G. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1678188 · Cited by 69
An improved wall filter for flow imaging of low velocity flow
Thomas, E. J., & Hall (1994) · doi:10.1109/ultsym.1994.401918 · Cited by 64
Minimax Risk of Matrix Denoising by Singular Value ThresholdingPreprint
(2014) · Cited by 58
Adaptive clutter filtering for ultrasound color flow imaging
Yoo, Y. M., Managuli, R., & Kim, Y. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)01014-7 · Cited by 52
Synthetic focus imaging using partial datasets
Cooley, & Робинсон (1994) · doi:10.1109/ultsym.1994.401884 · Cited by 48
Bias and Variance in the Estimate of the Doppler Frequency Induced by a Wall Motion Filter
Jc, W., Nowicki, A., Meister, J. ‐., Palma, F. D., & Pante, G. (1989) · Ultrasonic Imaging · doi:10.1177/016173468901100304 · Cited by 47
Bias in mean frequency estimation of Doppler signals due to wall clutter filters
Tysoe, C., & Evans, D. H. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)00009-g · Cited by 35
Flagged first, then by citations
Cited by
Sorted by citations
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,359
Self-citationA gut-derived metabolite alters brain activity and anxiety behaviour in mice
Needham, B. D., Funabashi, M., Adame, M. D., Wang, Z., Boktor, J. C., Haney, J., Wu, W.-L., Rabut, C., Ladinsky, M. S., Hwang, S.-J., et al. (2022) · Nature · doi:10.1038/s41586-022-04396-8 · Cited by 489
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 454
Self-citationTranscranial ultrafast ultrasound localization microscopy of brain vasculature in patients
Demené, C., Robin, J., Dizeux, A., Heiles, B., Pernot, M., Tanter, M., & Perren, F. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00697-x · Cited by 372
Self-citationBaranger, J., Arnal, B., Perren, F., Baud, O., Tanter, M., & Demené, C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2789499 · Cited by 353
Self-citation
Metadata
- Authors
- Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., Cohen, I., Baud, O., & Tanter, M.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Inserm (FR)
- ORCID
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2015-11
- Volume
- 34
- Issue
- 11
- Pages
- 2271-2285
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2070712157
- Cited by
- 983
- References
- 39
- Citations by year
- 2026: 79 · 2025: 137 · 2024: 120 · 2023: 107 · 2022: 102 · 2021: 103 · 2020: 95 · 2019: 80 · 2018: 71 · 2017: 56 · 2016: 27 · 2015: 6
- FWCI
- 43.18
- Type
- journal article
- Language
- en
- Open access
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- HAL (submittedVersion)
- Funders
- Agence Nationale de la Recherche (ANR-10-IDEX-0001)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Keywords
- ultrafast ultrasound imaging, clutter suppression, Doppler imaging, blood flow detection, tissue motion, microvascular networks, neonatal brain imaging
- MeSH terms
- Animals, Blood Flow Velocity, Echoencephalography, Humans, Image Processing, Computer-Assisted, Infant, Newborn, Kidney, Signal Processing, Computer-Assisted, Models, Statistical, Rats, Sprague-Dawley, Ultrasonography, Doppler, Phantoms, Imaging, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review