The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity
Open accessAbstract
Ultrafast ultrasonic imaging is a rapidly developing field based on the unfocused transmission of plane or diverging ultrasound waves. This recent approach to ultrasound imaging leads to a large increase in raw ultrasound data available per acquisition. Bigger synchronous ultrasound imaging datasets can be exploited in order to strongly improve the discrimination between tissue and blood motion in the field of Doppler imaging. Here we propose a spatiotemporal singular value decomposition clutter rejection of ultrasonic data acquired at ultrafast frame rate. The singular value decomposition (SVD) takes benefits of the different features of tissue and blood motion in terms of spatiotemporal coherence and strongly outperforms conventional clutter rejection filters based on high pass temporal filtering. Whereas classical clutter filters operate on the temporal dimension only, SVD clutter filtering provides up to a four-dimensional approach (3D in space and 1D in time). We demonstrate the performance of SVD clutter filtering with a flow phantom study that showed an increased performance compared to other classical filters (better contrast to noise ratio with tissue motion between 1 and 10mm/s and axial blood flow as low as 2.6 mm/s). SVD clutter filtering revealed previously undetected blood flows such as microvascular networks or blood flows corrupted by significant tissue or probe motion artifacts. We report in vivo applications including small animal fUltrasound brain imaging (blood flow detection limit of 0.5 mm/s) and several clinical imaging cases, such as neonate brain imaging, liver or kidney Doppler imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“removing the N = 60 first components of the singular value decomposition, which optimally exploited the spatiotemporal dynamics of the full Doppler film for clutter rejection, largely outperforming conventional clutter-rejection filters used in Doppler ultrasound47.”
From Local hippocampal fast gamma rhythms precede brain-wide hyperemic patterns during spontaneous rodent REM sleep (2018) · cites this paper as [47]
Citations
Cites
Robust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. N. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 7,048
The approximation of one matrix by another of lower rank
Eckart, C., & Young, G. (1936) · Psychometrika · doi:10.1007/bf02288367 · Cited by 4,497
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,496
Self-citationCoherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,824
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,157
Self-citationFunctional ultrasound imaging of the brain
Macé, É., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 806
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.6689779 · Cited by 697
Self-citationOtazo, R., Candès, E. J., & Sodickson, D. K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 667
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savéry, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 514
Self-citation
Cited by
Sorted by citations
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,359
Self-citationA gut-derived metabolite alters brain activity and anxiety behaviour in mice
Needham, B. D., Funabashi, M., Adame, M. D., Wang, Z., Boktor, J. C., Haney, J., Wu, W.-L., Rabut, C., Ladinsky, M. S., Hwang, S.-J., et al. (2022) · Nature · doi:10.1038/s41586-022-04396-8 · Cited by 489
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 454
Self-citationTranscranial ultrafast ultrasound localization microscopy of brain vasculature in patients
Demené, C., Robin, J., Dizeux, A., Heiles, B., Pernot, M., Tanter, M., & Perren, F. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00697-x · Cited by 372
Self-citationBaranger, J., Arnal, B., Perren, F., Baud, O., Tanter, M., & Demené, C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2789499 · Cited by 353
Self-citationDeep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
Opacic, T., Dencks, S., Theek, B., Piepenbrock, M., Ackermann, D., Rix, A., Lammers, T., Stickeler, E., Delorme, S., Schmitz, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03973-8 · Cited by 315
Song, P., Trzasko, J. D., Manduca, A., Huang, R., Kadirvel, R., Kallmes, D. F., & Chen, S. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2778941 · Cited by 285
Microglia modulate blood flow, neurovascular coupling, and hypoperfusion via purinergic actions
Császár, E., Lénárt, N., Cserép, C., Környei, Z., Fekete, R., Pósfai, B., Balázsfi, D., Hangya, B., Schwarcz, A. D., Szabadits, E., et al. (2022) · The Journal of Experimental Medicine · doi:10.1084/jem.20211071 · Cited by 274
Ultrasound Small Vessel Imaging With Block-Wise Adaptive Local Clutter Filtering
Song, P., Manduca, A., Trzasko, J. D., & Chen, S. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2605819 · Cited by 260
Lin, F., Shelton, S. E., Espíndola, D., Rojas, J. D., Pinton, G., & Dayton, P. A. (2016) · Theranostics · doi:10.7150/thno.16899 · Cited by 259
Heiles, B., Chavignon, A., Hingot, V., Pauline, L., Teston, E., & Couture, O. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00824-8 · Cited by 250
Ultrasound imaging of gene expression in mammalian cells
Farhadi, A., Ho, G. H., Sawyer, D. P., Bourdeau, R. W., & Shapiro, M. G. (2019) · Science · doi:10.1126/science.aax4804 · Cited by 242
Deep Unfolded Robust PCA With Application to Clutter Suppression in Ultrasound
Solomon, O., Cohen, R., Zhang, Y., Yang, Y., He, Q., Luo, J., van Sloun, R. J. G., & Eldar, Y. C. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2941271 · Cited by 219
Apelian, C., Harms, F., Thouvenin, O., & Boccara, C. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.001511 · Cited by 217
Functional ultrasound imaging of brain activity in human newborns
Demene, C., Baranger, J., Bernal, M., Delanoe, C., Auvin, S., Biran, V., Alison, M., Mairesse, J., Harribaud, E., Pernot, M., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aah6756 · Cited by 207
Self-citation4D functional ultrasound imaging of whole-brain activity in rodents
Rabut, C., Correia, M., Finel, V., Pezet, S., Pernot, M., Deffieux, T., & Tanter, M. (2019) · Nature Methods · doi:10.1038/s41592-019-0572-y · Cited by 214
Self-citationFunctional ultrasound neuroimaging: a review of the preclinical and clinical state of the art
Deffieux, T., Demené, C., Pernot, M., & Tanter, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.02.001 · Cited by 201
Self-citationHingot, V., Errico, C., Heiles, B., Rahal, L., Tanter, M., & Couture, O. (2019) · Scientific Reports · doi:10.1038/s41598-018-38349-x · Cited by 196
Self-citationRenaudin, N., Demené, C., Dizeux, A., Ialy-Radio, N., Pezet, S., & Tanter, M. (2022) · Nature Methods · doi:10.1038/s41592-022-01549-5 · Cited by 204
Self-citationLight controls cerebral blood flow in naive animals
Rungta, R. L., Osmanski, B.-F., Boido, D., Tanter, M., & Charpak, S. (2017) · Nature Communications · doi:10.1038/ncomms14191 · Cited by 172
Self-citationUltrasound localization microscopy to image and assess microvasculature in a rat kidney
Foiret, J. L., Zhang, H., Ilovitsh, T., Mahakian, L. M., Tam, S. M., & Ferrara, K. W. (2017) · Scientific Reports · doi:10.1038/s41598-017-13676-7 · Cited by 170
Huang, C., Zhang, W., Gong, P., Lok, U., Tang, S., Yin, T., Zhang, X., Zhu, L., Sang, M., Song, P., et al. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abef45 · Cited by 164
High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation
Porée, J., Posada, D., Hodžić, A., Tournoux, F., Cloutier, G., & Garcia, D. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2523346 · Cited by 162
Two-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb
Harput, S., Christensen-Jeffries, K. M., Brown, J., Li, Y., Williams, K. J., Davies, A. H., Eckersley, R. J., Dunsby, C. W., & Tang, M. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2824846 · Cited by 156
Ultrafast 3D Ultrasound Localization Microscopy Using a 32 $\times$ 32 Matrix Array
Heiles, B., Correia, M., Hingot, V., Pernot, M., Provost, J., Tanter, M., & Couture, O. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2890358 · Cited by 173
Self-citationUltrasound Vector Flow Imaging—Part II: Parallel Systems
Jensen, J. A., Nikolov, S. I., Yu, A. C. H., & Garcia, D. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2598180 · Cited by 154
Transcranial volumetric imaging using a conformal ultrasound patch
Zhou, S., Gao, X., Park, G., Yang, X., Qi, B., Lin, M., Huang, H., Bian, Y., Hu, H., Chen, X., et al. (2024) · Nature · doi:10.1038/s41586-024-07381-5 · Cited by 157
Functional Ultrasound Imaging: A New Imaging Modality for Neuroscience
Deffieux, T., Demené, C., & Tanter, M. (2021) · Neuroscience · doi:10.1016/j.neuroscience.2021.03.005 · Cited by 140
Self-citation4D microvascular imaging based on ultrafast Doppler tomography
Demené, C., Tiran, E., Sieu, L.-A., Bergel, A., Gennisson, J. L., Pernot, M., Deffieux, T., Cohen, I., & Tanter, M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.014 · Cited by 139
Self-citationDizeux, A., Gesnik, M., Ahnine, H., Blaize, K., Arcizet, F., Picaud, S. A., Sahel, J., Deffieux, T., Pouget, P., & Tanter, M. (2019) · Nature Communications · doi:10.1038/s41467-019-09349-w · Cited by 151
Self-citationIntraoperative Functional Ultrasound Imaging of Human Brain Activity
Imbault, M., Chauvet, D., Gennisson, J., Capelle, L., & Tanter, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-06474-8 · Cited by 136
Self-citationSubwavelength motion-correction for ultrafast ultrasound localization microscopy
Hingot, V., Errico, C., Tanter, M., & Couture, O. (2017) · Ultrasonics · doi:10.1016/j.ultras.2017.01.008 · Cited by 135
Self-citation3-D ultrafast doppler imaging applied to the noninvasive mapping of blood vessels in Vivo
Provost, J., Papadacci, C., Demené, C., Gennisson, J., Tanter, M., & Pernot, M. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2015.007032 · Cited by 133
Self-citationDeep Learning for Ultrasound Localization Microscopy
Liu, X., Zhou, T., Lu, M., Yang, Y., He, Q., & Luo, J. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2986781 · Cited by 138
Demeulenaere, O., Bertolo, A., Pezet, S., Ialy-Radio, N., Osmanski, B.-F., Papadacci, C., Tanter, M., Deffieux, T., & Pernot, M. (2022) · EBioMedicine · doi:10.1016/j.ebiom.2022.103995 · Cited by 130
Self-citationErrico, C., Osmanski, B.-F., Pezet, S., Couture, O., Lenkei, Z., & Tanter, M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.09.037 · Cited by 143
Self-citationCorreia, M., Provost, J., Tanter, M., & Pernot, M. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/23/l48 · Cited by 124
Self-citationKalman Filter-Based Microbubble Tracking for Robust Super-Resolution Ultrasound Microvessel Imaging
Tang, S., Song, P., Trzasko, J. D., Lowerison, M. R., Huang, C., Gong, P., Lok, U., Manduca, A., & Chen, S. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.2984384 · Cited by 124
Fast Vascular Ultrasound Imaging With Enhanced Spatial Resolution and Background Rejection
Bar‐Zion, A., Tremblay‐Darveau, C., Solomon, O., Adam, D., & Eldar, Y. C. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2600372 · Cited by 123
SUSHI: Sparsity-Based Ultrasound Super-Resolution Hemodynamic Imaging
Bar‐Zion, A., Solomon, O., Tremblay‐Darveau, C., Adam, D., & Eldar, Y. C. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2873380 · Cited by 126
Super-resolution ultrasound microvascular imaging: Is it ready for clinical use?
Song, P., Rubin, J. M., & Lowerison, M. R. (2023) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2023.04.001 · Cited by 122
Multiplane wave imaging increases signal-to-noise ratio in ultrafast ultrasound imaging
Tiran, E., Deffieux, T., Correia, M., Maresca, D., Osmanski, B.-F., Sieu, L., Bergel, A., Cohen, I., Pernot, M., & Tanter, M. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/8549 · Cited by 121
Self-citation3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
Harput, S., Christensen-Jeffries, K. M., Ramalli, A., Brown, J., Zhu, J., Zhang, G., Leow, C. H., Toulemonde, M. E. G., Boni, E., Tortoli, P., et al. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2943646 · Cited by 121
Bergel, A., Deffieux, T., Demené, C., Tanter, M., & Cohen, I. (2018) · Nature Communications · doi:10.1038/s41467-018-07752-3 · Cited by 117
Self-citationWhole-brain functional ultrasound imaging in awake head-fixed mice
Brunner, C., Grillet, M., Urban, A., Roska, B., Montaldo, G., & Macé, É. (2021) · Nature Protocols · doi:10.1038/s41596-021-00548-8 · Cited by 125
Tiran, E., Ferrier, J., Deffieux, T., Gennisson, J., Pezet, S., Lenkei, Z., & Tanter, M. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.03.011 · Cited by 117
Self-citation3D Transcranial Ultrasound Localization Microscopy in the Rat Brain With a Multiplexed Matrix Probe
Chavignon, A., Heiles, B., Hingot, V., Orset, C., Vivien, D., & Couture, O. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3137265 · Cited by 136
Chen, Q., Yu, J., Rush, B. M., Stocker, S. D., Tan, R. J., & Kim, K. (2020) · Kidney International · doi:10.1016/j.kint.2020.02.011 · Cited by 114
Single-trial decoding of movement intentions using functional ultrasound neuroimaging
Norman, S. L., Maresca, D., Christopoulos, V. N., Griggs, W. S., Demené, C., Tanter, M., Shapiro, M. G., & Andersen, R. A. (2021) · Neuron · doi:10.1016/j.neuron.2021.03.003 · Cited by 121
Self-citation3D functional ultrasound imaging of the cerebral visual system in rodents
Gesnik, M., Blaize, K., Deffieux, T., Gennisson, J., Sahel, J., Fink, M., Picaud, S. A., & Tanter, M. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.071 · Cited by 109
Self-citationMesoscopic and microscopic imaging of sensory responses in the same animal
Boido, D., Rungta, R. L., Osmanski, B.-F., Roche, M., Tsurugizawa, T., Bihan, D. L., Ciobanu, L., & Charpak, S. (2019) · Nature Communications · doi:10.1038/s41467-019-09082-4 · Cited by 103
Self-citationSoloukey, S., Vincent, A. J. P. E., Satoer, D., Mastik, F., Smits, M., Dirven, C. M. F., Strydis, C., Bosch, J. G., van der Steen, A. F. W., Zeeuw, C. I. D., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01384 · Cited by 105
Flesch, M., Pernot, M., Provost, J., Férin, G., Nguyen-Dinh, A., Tanter, M., & Deffieux, T. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa63d9 · Cited by 104
Self-citationUltrafast Ultrasound Imaging in Pediatric and Adult Cardiology
Villemain, O., Baranger, J., Friedberg, M. K., Papadacci, C., Dizeux, A., Messas, E., Tanter, M., Pernot, M., & Mertens, L. (2019) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2019.09.019 · Cited by 104
Self-citationNeural correlates of blood flow measured by ultrasound
Núñez-Elizalde, A. O., Krumin, M., Reddy, C. B., Montaldo, G., Urban, A., Harris, K. D., & Carandini, M. (2022) · Neuron · doi:10.1016/j.neuron.2022.02.012 · Cited by 103
Transthoracic ultrasound localization microscopy of myocardial vasculature in patients
Yan, J., Huang, B., Tonko, J., Toulemonde, M. E. G., Hansen-Shearer, J. T. T., Tan, Q., Riemer, K., Ntagiantas, K., Chowdhury, R. A., Lambiase, P. D., et al. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01206-6 · Cited by 99
Yu, J., Lavery, L., & Kim, K. (2018) · Scientific Reports · doi:10.1038/s41598-018-32235-2 · Cited by 98
Bedside functional monitoring of the dynamic brain connectivity in human neonates
Baranger, J., Demené, C., Frérot, A., Faure, F., Delanöe, C., Serroune, H., Houdouin, A., Mairesse, J., Biran, V., Baud, O., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-21387-x · Cited by 97
Self-citationSong, P., Trzasko, J. D., Manduca, A., Qiang, B., Kadirvel, R., Kallmes, D. F., & Chen, S. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2665342 · Cited by 95
4D Functional Imaging of the Rat Brain Using a Large Aperture Row-Column Array
Sauvage, J., Porée, J., Rabut, C., Férin, G., Flesch, M., Rosinski, B., Nguyen‐Dinh, A., Tanter, M., Pernot, M., & Deffieux, T. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2959833 · Cited by 94
Self-citationZhang, J., He, Q., Xiao, Y., Zheng, H., Wang, C., & Luo, J. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102018 · Cited by 94
A Deep Learning Framework for Spatiotemporal Ultrasound Localization Microscopy
Milecki, L., Porée, J., Belgharbi, H., Bourquin, C., Damseh, R., Delafontaine-Martel, P., Lesage, F., Gasse, M., & Provost, J. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3056951 · Cited by 93
Transfer functions linking neural calcium to single voxel functional ultrasound signal
Aydin, A.-K., Haselden, W. D., Houssen, Y. G., Pouzat, C., Rungta, R. L., Demené, C., Tanter, M., Drew, P. J., Charpak, S., & Boido, D. (2020) · Nature Communications · doi:10.1038/s41467-020-16774-9 · Cited by 93
Self-citationCoronary Flow Assessment Using 3-Dimensional Ultrafast Ultrasound Localization Microscopy
Demeulenaere, O., Sandoval, Z., Matéo, P., Dizeux, A., Villemain, O., Gallet, R., Ghaleh, B., Deffieux, T., Demené, C., Tanter, M., et al. (2022) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2022.02.008 · Cited by 89
Self-citationBimbard, C., Demené, C., Girard, C., Radtke‐Schuller, S., Shamma, S., Tanter, M., & Boubenec, Y. (2018) · eLife · doi:10.7554/elife.35028 · Cited by 83
Self-citationPower cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles
Burgess, M. T., Apostolakis, I., & Konofagou, E. E. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aab05c · Cited by 92
Functional ultrasound imaging of deep visual cortex in awake nonhuman primates
Blaize, K., Arcizet, F., Gesnik, M., Ahnine, H., Ferrari, U., Deffieux, T., Pouget, P., Chavane, F., Fink, M., Sahel, J., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1916787117 · Cited by 81
Self-citationContrast enhanced ultrasound by real-time spatiotemporal filtering of ultrafast images
Desailly, Y., Tissier, A.-M., Corréas, J.-M., Wintzenrieth, F., Tanter, M., & Couture, O. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/62/1/31 · Cited by 81
Self-citationShin, Y., Lowerison, M. R., Wang, Y., Chen, X., You, Q., Dong, Z., Anastasio, M. A., & Song, P. (2024) · Nature Communications · doi:10.1038/s41467-024-47154-2 · Cited by 84
Noise Equalization for Ultrafast Plane Wave Microvessel Imaging
Song, P., Manduca, A., Trzasko, J. D., & Chen, S. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2748387 · Cited by 79
Lok, U., Song, P., Trzasko, J. D., Daigle, R. E., Borisch, E. A., Huang, C., Gong, P., Tang, S., Ling, W., & Chen, S. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106163 · Cited by 78
Ferrier, J., Tiran, E., Deffieux, T., Tanter, M., & Lenkei, Z. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1920475117 · Cited by 73
Self-citationBackground Removal and Vessel Filtering of Noncontrast Ultrasound Images of Microvasculature
Bayat, M., Fatemi, M., & Alizad, A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2858205 · Cited by 77
Rabut, C., Norman, S. L., Griggs, W. S., Russin, J. J., Jann, K., Christopoulos, V., Liu, C. Y., Andersen, R. A., & Shapiro, M. G. (2024) · Science Translational Medicine · doi:10.1126/scitranslmed.adj3143 · Cited by 76
4-D Intracardiac Ultrasound Vector Flow Imaging–Feasibility and Comparison to Phase-Contrast MRI
Wigen, M. S., Fadnes, S., Rodríguez-Molares, A., Bjastad, T. G., Eriksen, M., Stensæth, K. H., Støylen, A., & Løvstakken, L. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2844552 · Cited by 75
Ultrasensitive ultrasound imaging of gene expression with signal unmixing
Sawyer, D. P., Bar‐Zion, A., Farhadi, A., Shivaei, S., Ling, B., Lee‐Gosselin, A., & Shapiro, M. G. (2021) · Nature Methods · doi:10.1038/s41592-021-01229-w · Cited by 74
Super-resolution photoacoustic imaging via flow-induced absorption fluctuations
Chaigne, T., Arnal, B., Вилов, С. А., Bossy, E., & Katz, O. (2017) · Optica · doi:10.1364/optica.4.001397 · Cited by 74
A large aperture row column addressed probe for in vivo 4D ultrafast doppler ultrasound imaging
Sauvage, J., Flesch, M., Férin, G., Nguyen-Dinh, A., Porée, J., Tanter, M., Pernot, M., & Deffieux, T. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aae427 · Cited by 70
Self-citationDeep Learning of Spatiotemporal Filtering for Fast Super-Resolution Ultrasound Imaging
Brown, K., Ghosh, D., & Hoyt, K. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.2988164 · Cited by 70
Lim, A. K. P., Satchithananda, K., Dick, E., Abraham, S., & Cosgrove, D. O. (2017) · European Radiology · doi:10.1007/s00330-017-5016-4 · Cited by 69
Ultrafast Doppler for neonatal brain imaging
Demené, C., Mairesse, J., Baranger, J., Tanter, M., & Baud, O. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.04.016 · Cited by 66
Self-citationDecoding motor plans using a closed-loop ultrasonic brain–machine interface
Griggs, W. S., Norman, S. L., Deffieux, T., Segura, F., Osmanski, B.-F., Chau, G., Christopoulos, V., Liu, C. Y., Tanter, M., Shapiro, M. G., et al. (2023) · Nature Neuroscience · doi:10.1038/s41593-023-01500-7 · Cited by 78
Self-citationUltrasound localization microscopy
Dencks, S., & Schmitz, G. (2023) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2023.02.004 · Cited by 65
Claron, J., Hingot, V., Rivals, I., Rahal, L., Couture, O., Deffieux, T., Tanter, M., & Pezet, S. (2020) · Pain · doi:10.1097/j.pain.0000000000002078 · Cited by 59
Self-citationDeep optoacoustic localization microangiography of ischemic stroke in mice
Deán‐Ben, X. L., Robin, J., Nozdriukhin, D. V., Ni, R., Zhao, J., Glück, C., Droux, J., Sendón-Lago, J., Chen, Z., Zhou, Q., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-39069-1 · Cited by 65
Ghosh, D., Peng, J., Brown, K., Sirsi, S. R., Mineo, C., Shaul, P. W., & Hoyt, K. (2019) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14956 · Cited by 65
Super-Resolution Imaging Through the Human Skull
Soulioti, D., Espíndola, D., Dayton, P. A., & Pinton, G. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2937733 · Cited by 63
Hingot, V., Brodin, C., Lebrun, F., Heiles, B., Chagnot, A., Yetim, M., Gauberti, M., Orset, C., Tanter, M., Couture, O., et al. (2020) · Theranostics · doi:10.7150/thno.44233 · Cited by 63
Self-citationProvost, J., Garofalakis, A., Sourdon, J., Bouda, D., Berthon, B., Viel, T., Pérez-Liva, M., Lussey‐Lepoutre, C., Favier, J., Correia, M., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0188-z · Cited by 62
Self-citationBourquin, C., Porée, J., Lesage, F., & Provost, J. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3123912 · Cited by 61
Deep Learning-Based Microbubble Localization for Ultrasound Localization Microscopy
Chen, X., Lowerison, M. R., Dong, Z., Han, A., & Song, P. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3152225 · Cited by 63
Debiasing-Based Noise Suppression for Ultrafast Ultrasound Microvessel Imaging
Huang, C., Song, P., Gong, P., Trzasko, J. D., Manduca, A., & Chen, S. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2918180 · Cited by 61
Li, Y. L., Hyun, D., Abou‐Elkacem, L., Willmann, J. K., & Dahl, J. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2616112 · Cited by 60
A functional ultrasound brain GPS for automatic vascular-based neuronavigation
Nouhoum, M., Ferrier, J., Osmanski, B.-F., Ialy-Radio, N., Pezet, S., Tanter, M., & Deffieux, T. (2021) · Scientific Reports · doi:10.1038/s41598-021-94764-7 · Cited by 55
Self-citationChang, C.-C., Chen, P., Huang, H., & Huang, C. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2878887 · Cited by 58
Improving plane wave ultrasound imaging through real-time beamformation across multiple arrays
Foiret, J. L., Cai, X., Bendjador, H., Park, E.-Y., Kamaya, A., & Ferrara, K. W. (2022) · Scientific Reports · doi:10.1038/s41598-022-16961-2 · Cited by 57
Chavignon, A., Hingot, V., Orset, C., Vivien, D., & Couture, O. (2022) · Scientific Reports · doi:10.1038/s41598-022-18025-x · Cited by 53
Rabut, C., Ferrier, J., Bertolo, A., Osmanski, B.-F., Mousset, X., Pezet, S., Deffieux, T., Lenkei, Z., & Tanter, M. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117231 · Cited by 63
Self-citationHybrid photoacoustic and fast super-resolution ultrasound imaging
Zhao, S., Hartanto, J., Joseph, R., Wu, C.-H., Zhao, Y., & Chen, Y. (2023) · Nature Communications · doi:10.1038/s41467-023-37680-w · Cited by 57
Metadata
- Authors
- Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., Cohen, I., Baud, O., & Tanter, M.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Inserm (FR)
- ORCID
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2015-11
- Volume
- 34
- Issue
- 11
- Pages
- 2271-2285
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2070712157
- Cited by
- 983
- References
- 39
- Citations by year
- 2026: 79 · 2025: 137 · 2024: 120 · 2023: 107 · 2022: 102 · 2021: 103 · 2020: 95 · 2019: 80 · 2018: 71 · 2017: 56 · 2016: 27 · 2015: 6
- FWCI
- 43.18
- Type
- journal article
- Language
- en
- Open access
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- HAL (submittedVersion)
- Funders
- Agence Nationale de la Recherche (ANR-10-IDEX-0001)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Keywords
- ultrafast ultrasound imaging, clutter suppression, Doppler imaging, blood flow detection, tissue motion, microvascular networks, neonatal brain imaging
- MeSH terms
- Animals, Blood Flow Velocity, Echoencephalography, Humans, Image Processing, Computer-Assisted, Infant, Newborn, Kidney, Signal Processing, Computer-Assisted, Models, Statistical, Rats, Sprague-Dawley, Ultrasonography, Doppler, Phantoms, Imaging, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review