CoChat

Towards Personalized Statistical Deformable Model and Hybrid Point Matching for Robust MR-TRUS Registration

Wang, Yi, Cheng, Jie-Zhi, Ni, Dong, Lin, Muqing, Qin, Jing, Luo, Xiongbiao, Xu, Ming, Xie, Xiaoyan, Heng, Pheng Ann · 2016 · IEEE Transactions on Medical Imaging
Cited by 46

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Registration and fusion of magnetic resonance (MR) and 3D transrectal ultrasound (TRUS) images of the prostate gland can provide high-quality guidance for prostate interventions. However, accurate MR-TRUS registration remains a challenging task, due to the great intensity variation between two modalities, the lack of intrinsic fiducials within the prostate, the large gland deformation caused by the TRUS probe insertion, and distinctive biomechanical properties in patients and prostate zones. To address these challenges, a personalized model-to-surface registration approach is proposed in this study. The main contributions of this paper can be threefold. First, a new personalized statistical deformable model (PSDM) is proposed with the finite element analysis and the patient-specific tissue parameters measured from the ultrasound elastography. Second, a hybrid point matching method is developed by introducing the modality independent neighborhood descriptor (MIND) to weight the Euclidean distance between points to establish reliable surface point correspondence. Third, the hybrid point matching is further guided by the PSDM for more physically plausible deformation estimation. Eighteen sets of patient data are included to test the efficacy of the proposed method. The experimental results demonstrate that our approach provides more accurate and robust MR-TRUS registration than state-of-the-art methods do. The averaged target registration error is 1.44 mm, which meets the clinical requirement of 1.9 mm for the accurate tumor volume detection. It can be concluded that the presented method can effectively fuse the heterogeneous image information in the elastography, MR, and TRUS to attain satisfactory image alignment performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2015.2485299

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 46

Metadata

Authors
Wang, Y., Cheng, J.-Z., Ni, D., Lin, M., Qin, J., Luo, X., Xu, M., Xie, X., & Heng, P. A.
Venue
IEEE Transactions on Medical Imaging
Published
2016-02
Volume
35
Issue
2
Pages
589-604
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2280845481
Cited by
46
References
3
FWCI
5.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Towards Personalized Statistical Deformable Model and Hybrid Point Matching for Robust MR-TRUS Registration. https://app.cochat.ai/papers/10.1109/tmi.2015.2485299
The paper
Wang, Y., Cheng, J.-Z., Ni, D., Lin, M., Qin, J., Luo, X., Xu, M., Xie, X., & Heng, P. A. (2016). Towards Personalized Statistical Deformable Model and Hybrid Point Matching for Robust MR-TRUS Registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2015.2485299

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.