The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening
Abstract
The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and validated. The main contribution is a new set of shape features, called Dynamic Shape Features, that do not require precise segmentation of the regions to be classified. These features represent the evolution of the shape during image flooding and allow to discriminate between lesions and vessel segments. The method is validated per-lesion and per-image using six databases, four of which are publicly available. It proves to be robust with respect to variability in image resolution, quality and acquisition system. On the Retinopathy Online Challenge's database, the method achieves a FROC score of 0.420 which ranks it fourth. On the Messidor database, when detecting images with diabetic retinopathy, the proposed method achieves an area under the ROC curve of 0.899, comparable to the score of human experts, and it outperforms state-of-the-art approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global prevalence and major risk factors of diabetic retinopathy
Yau, J. W. Y., Rogers, S. L., Kawasaki, R., Lamoureux, E. L., Kowalski, J. W., Bek, T., Chen, S.-J., Dekker, J. M., Fletcher, A., Grauslund, J., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1909 · Cited by 4,985
Cited by
Automated Identification of Diabetic Retinopathy Using Deep Learning
Gargeya, R., & Leng, T. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.02.008 · Cited by 1,362
A Deep Learning Ensemble Approach for Diabetic Retinopathy Detection
Qummar, S., Khan, F. G., Shah, S., Khan, A., Shamshirband, S., Rehman, Z. U., Ahmed Khan, I., & Jadoon, W. (2019) · IEEE Access · doi:10.1109/access.2019.2947484 · Cited by 622
Fundus Image Classification Using VGG-19 Architecture with PCA and SVD
Mateen, M., Wen, J., Nasrullah, Song, S., & Huang, Z. (2018) · Symmetry · doi:10.3390/sym11010001 · Cited by 614
A Survey on ensemble learning under the era of deep learning
Yang, Y., Lv, H., & Chen, N. (2023) · Artificial Intelligence Review · doi:10.1007/s10462-022-10283-5 · Cited by 369
An ensemble deep learning based approach for red lesion detection in fundus images
Orlando, J. I., Prokofyeva, E., del Fresno, M., & Blaschko, M. B. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.10.017 · Cited by 293
Metadata
- Authors
- Seoud, L., Hurtut, T., Chelbi, J., Cheriet, F., & Langlois, J. M. P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2016-04
- Volume
- 35
- Issue
- 4
- Pages
- 1116-1126
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2239579562
- Cited by
- 277
- References
- 1
- FWCI
- 14.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening. https://app.cochat.ai/papers/10.1109/tmi.2015.2509785
- The paper
- Seoud, L., Hurtut, T., Chelbi, J., Cheriet, F., & Langlois, J. M. P. (2016). Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2015.2509785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.