High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
High-frame-rate ultrasonography based on coherent compounding of unfocused beams can potentially transform the assessment of cardiac function. As it requires successive waves to be combined coherently, this approach is sensitive to high-velocity tissue motion. We investigated coherent compounding of tilted diverging waves, emitted from a 2.5 MHz clinical phased array transducer. To cope with high myocardial velocities, a triangle transmit sequence of diverging waves is proposed, combined with tissue Doppler imaging to perform motion compensation (MoCo). The compound sequence with integrated MoCo was adjusted from simulations and was tested in vitro and in vivo. Realistic myocardial velocities were analyzed in an in vitro spinning disk with anechoic cysts. While a 8 dB decrease (no motion versus high motion) was observed without MoCo, the contrast-to-noise ratio of the cysts was preserved with the MoCo approach. With this method, we could provide high-quality in vivo B-mode cardiac images with tissue Doppler at 250 frames per second. Although the septum and the anterior mitral leaflet were poorly apparent without MoCo, they became well perceptible and well contrasted with MoCo. The septal and lateral mitral annulus velocities determined by tissue Doppler were concordant with those measured by pulsed-wave Doppler with a clinical scanner (r(2)=0.7,y=0.9 x+0.5,N=60) . To conclude, high-contrast echo cardiographic B-mode and tissue Doppler images can be obtained with diverging beams when motion compensation is integrated in the coherent compounding process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367 · cited 1×
“Nowadays, echocardiography is the gold standard to detect congenital diseases [1], diagnose valvular diseases [2], and assess left ventricular function [3], among others.”
BackgroundRecommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351 · cited 1×
“Nowadays, echocardiography is the gold standard to detect congenital diseases [1], diagnose valvular diseases [2], and assess left ventricular function [3], among others.”
BackgroundNagueh, S. F., Middleton, K. J., Kopelen, H. A., Zoghbi, W. A., & Quiñones, M. A. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00344-6 · Cited by 3,029 · cited 2×
“dial velocities [27].”
BackgroundCalculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493 · cited 1×
“2 illustrates how tissue motion may deteriorate images: we simulated scatterers moving vertically upward at 15 cm/s using Field II [29], [30].”
MethodBoone, K. G., & Holder, D. S. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520003 · Cited by 1,919
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814 · cited 1×
“This can produce an image of comparable quality as conventional focusing [20].”
BackgroundUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983 · cited 1×
“11), SVD clutter filters could also be used for a better assessment of tissue velocities [43].”
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510 · cited 1×
“To preserve a high Nyquist limit, we did not perform coherent compounding before Doppler estimation (as in [32], [33]; (= 32) successive transmits provided one tissue Doppler image and onemotion-compensated B-mode image.”
MethodA fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479 · cited 3×
“In this study, we had to face a dilemma: on the one hand, uncorrelated signals are preferred to get high-contrast B-mode images, but on the other hand, partially correlated signals must be favored to reduce the variance of the phase delay estimates, as established by the Cramér-Rao bound [34].”
BackgroundMethodInfluential
Cited by
So you think you can DAS? A viewpoint on delay-and-sum beamforming
Perrot, V., Polichetti, M., Varray, F., & Garcia, D. (2021) · Ultrasonics · doi:10.1016/j.ultras.2020.106309 · Cited by 377
Self-citation
Metadata
- Authors
- Poree, J., Posada, D., Hodzic, A., Tournoux, F., Cloutier, G., & Garcia, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2016-07
- Volume
- 35
- Issue
- 7
- Pages
- 1647-1657
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2344293268
- Cited by
- 160
- References
- 24
- FWCI
- 17.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.